Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Journal of the Japan Society of Acupuncture and Moxibustion ; : 1-5, 1987.
Article in Japanese | WPRIM | ID: wpr-370557

ABSTRACT

Pulses were taken by using three sensors, one of whitch was put on top of the index finger, another on the middle finger and the last on the ring finger.<br>Pulses were taken from patients and normal subjects and were described as pressure pulse waves.<br>The pressure of the tips of fingers when doing a pulse diagnosis was measure for seven chinese doctors. Consequently, we confirmed that the pressure was distributed widely and the technique of pulse diagnosis included a lot of individual factors.<br>On the other hand, we found several pressure pulse waves were significant in relation to findings of pulse diagnosis.

2.
Journal of the Japan Society of Acupuncture and Moxibustion ; : 17-26, 1981.
Article in Japanese | WPRIM | ID: wpr-370412

ABSTRACT

At the 30th general meeting of this association we reported the value of conducting a fundamental, methodological study of stellate ganglion insertion on the basis of clinical indications obtained from clinical results indicating that stellate ganglion insertion (hereafter referred to as SG insertion) on the affected side is appropriate for the treatment of the central sensory dis-turbances, especially numbness of the arms on the afflicted side, accompanying post cerebral apoplexy syndromes.<br>At this time we'd like to report, using cutaneous surface temperature as an index, the results of examinations of the inflnences exerted on circulatory fluctuation by SG insertion, from among our fundamental study of the functional mechanism of SG insertion.<br>The cutaneous surface temperature was measured using a Fujitsu made Infra-eye 150 thermograph. After the clothing from the upper half of the body was removed and the patient had rested in a sitting position for 20 minutes in a temperature-humieity controlled room, the body was monitored and from the picture obtained the cutaneous surface temperature at the 5 points used in this study, GB-14, LI-20, SI-18, _??__??_, and LI-14, measured.<br>There was no significant difference in the cutaneous surface temperatures at the facial points on healthy subjects and hemiplegia patients, however it was discovered that on points on the upper extremities the readings on the affected side were significantly lower than those of healthy subjects or those on the healthy side, moreover readings on affected sides in which numbness was reported were significantly lower than on the affected sides in cases in which no numbness was reported.<br>Results upon administering SG insertion to above cases in which there was reported numbness and measuring sutaneous surface temperatures periodically revealed that the difference in temperature 15 minutes after operations decreased slightly with a tendency to become greater than before operations 2 hours afterward. Also the interesting observation that the correlation of reciprocity of the 6 points varied acording to SG insertion, was made.

SELECTION OF CITATIONS
SEARCH DETAIL