Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Chinese Journal of Radiological Health ; (6): 668-672, 2023.
Article in Chinese | WPRIM | ID: wpr-1006325

ABSTRACT

Objective To test and analyze the performance of Biograph Vision 600 PET/CT according to the NEMA NU2—2012 standard to achieve reliable, repeatable, and inter-system comparable performance measurement, and to provide a basis for future equipment stability testing and status detection. Methods The Biograph Vision PET equipment features a detector based on silicon photomultipliers, with 3.2 mm lutetium oxyorthosilicate crystals and full cover of the scintillation region. The spatial resolution, sensitivity, noise-equivalent count rate, scatter fraction, coincidence count rate, image quality, scatter correction, and time-of-flight resolution of Biograph Vision PET were tested by referring to the test model and method of the NEMA NU2—2012 standard. Results The Biograph Vision 600 PET equipment showed lateral and axial spatial resolutions of 3.69 mm and 3.81 mm at 1 cm off-center of the field of view, respectively and of 4.29 mm and 4.48 mm at 10 cm, respectively. The sensitivity was 17.5 kcps/MBq. The time-of-flight resolution changed from 210 ps to 215 ps as the count rate increased to the peak noise equivalent count rate. The NEMA peak noise-equivalent count rate was 247 kcps at 30.3 kBq/ml. The corresponding scatter fraction was 34.8%. With the NEMA module, the overall image quality contrast range was 73.6%-92.8%, and the background variability was 2.3%-6.5%; the mean lung residual error was 3.4%; and the time-of-flight resolution was 210 ps. Conclusion This performance test was performed according to the NEMA NU2—2012 standard, showing that all parameters were better than the ex-factory standard, which can provide a reference for other institutions selecting equipment and also provide a basis for future equipment stability testing and status detection.

2.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 277-280, 2023.
Article in Chinese | WPRIM | ID: wpr-993591

ABSTRACT

Objective:To evaluate the value of 99Tc m-methoxyisobutylisonitrile(MIBI) SPECT/CT imaging for the identification of dystonic muscles in patients with primary cervical dystonia (PCD). Methods:A total of 10 patients with PCD (3 males, 7 females, age (47.3±9.9) years) and 10 healthy subjects (4 males, 6 females, age (43.5±9.4) years; control group) between August 2019 and October 2021 in China-Japan Friendship Hospital were enrolled prospectively. All subjects underwent 99Tc m-MIBI SPECT/CT scan. The SUV max of 8 bilateral representative muscles, including rectus capitis posterior major, obliquus capitis inferior, splenius capitis, semispinalis, sternocleidomastoid, trapezius, musculus scalenus muscle and levator scapulae were evaluated in control group. In PCD group, muscles with abnormal uptake were determined. ROI was drawn and SUV max was measured. Independent-sample t test was used to analyze the differences of SUV max between normal and abnormal muscles. The detecting rates of neck MRI and SPECT/CT for abnormal muscles were analyzed by χ2 test. Results:Normal muscles of healthy subjects showed mild symmetrical radioactivity distribution, with the SUV max of 1.10±0.19. A total of 60 muscles with abnormal uptake in 10 patients were found, including 7 rectus capitis posterior major, 10 obliquus capitis inferior, 8 splenius capitis, 8 semispinalis, 10 sternocleidomastoid, 5 trapezius, 3 musculus scalenus muscle and 9 levator scapulae. The SUV max of muscles with abnormal uptake was 1.81±0.43, which was higher than that of normal muscles ( t=17.05, P<0.001). Only 30 pieces abnormal hypertrophy muscle were found by neck MRI, and the detecting rate was much lower than that of SPECT/CT (18.75%(30/160) vs 37.50%(60/160); χ2=28.03, P<0.001). Conclusion:99Tc m-MIBI SPECT/CT may be a useful method for identifying dystonic muscles and a guide to precision therapy in patients with PCD.

3.
Journal of Pharmaceutical Practice ; (6): 335-338, 2022.
Article in Chinese | WPRIM | ID: wpr-935032

ABSTRACT

Objective To investigate the medication adherence of military academy students with superficial mycoses. Methods A 8-item Morisky medication adherence scale (MMAS) was modified into 7-item scale to evaluate the compliance of antifungal drugs in the sick students. The reliability and validity of the scale were analyzed. Results A total of 243 questionnaires were collected, of which 242 were valid questionnaires. 90.08% of the students took topical medication and 8.68% were treated both with topical and systematic combination. High, medium and low medication adherence rates as assessed by the modified MMAS were 9.09%, 23.97% and 66.94%, respectively. The reliability analysis showed that the internal consistency coefficient (Cronbach’s α ) was 0.781,and the adjusted Cronbach’s α was 0.790, indicating the high reliability of the scale. The KMO value was 0.798, and the Bartlett’s spherical test value was 440.866, P=0.000. One factor was extracted by exploratory factor analysis. The factor loadings of the items were all above 0.5. Therefore, the high convergent validity was good. Conclusion The modified MMAS has good reliability and validity and is applicable for the evaluation of medication compliance for superficial mycoses. In this study, the military students have a low level of medication adherence for superficial mycoses. Effective measures should be taken to help students strengthen their daily medication management and improve compliance.

4.
Cancer Research and Clinic ; (6): 352-357, 2022.
Article in Chinese | WPRIM | ID: wpr-934684

ABSTRACT

Objective:To investigate the predictive value of 18F-FDG PET-CT in the conversion from thoracoscopic lobectomy to thoracotomy for non-small cell lung cancer (NSCLC). Methods:The clinical data, CT and PET-CT images of 193 patients with primary NSCLC undergoing thoracoscopic surgery from January 2014 to June 2021 at China-Japan Friendship Hospital were retrospectively analyzed. All patients were divided into 45 cases who were converted to thoracotomy (the conversional group) and 148 cases who were not converted to thoracotomy (the non-conversional group). Univariate analysis was performed on clinicopathological characteristics and image parameters. Multivariate logistic regression was used to analyze the factors affecting the conversion to thoracotomy. Taking the final conversion to thoracotomy or not as the gold standard, the predictive effect of variables in the conversion to thoracotomy was analyzed through the receiver operating characteristic (ROC) curve. Delong test was used to compare the area under the curve (AUC) predicted by all variables.Results:In the conversional group, the proportion of peribronchial lymph node (PLN), peribronchial cuffs of soft (PCS), pleural calcification, pulmonary nodule calcification, PLN or PCS calcification or increased density on chest CT was higher than that in the non-conversional group (all P<0.05); and the maximum standardized uptake value (SUV max) of PET in the conversional group was higher compared with that in the non-conversional group ( P<0.001). Univariate logistic regression analysis suggested age ( OR = 4.663,95% CI 2.191- 9.923, P < 0.001) and PLN or PCS density of chest CT scan ( OR = 2.824, 95% CI 1.791-7.303, P < 0.001) were independent influencing factors of the conversion from thoracoscopic lobectomy to thoracotomy. ROC analysis showed that the effect of the conversion to thoracotomy predicted by the combination of 18F-FDG PET and chest CT [AUC = 0.891 (95% CI 0.831-0.951); the optimal cut-off value of SUV max and CT was 3.45, 70 Hu: the sensitivity was 84.4%, the specificity was 83.8%] was better than that by chest CT alone [AUC = 0.678 (95% CI 0.591-0.766); the optimal cut-off value of CT was 70 Hu: the sensitivity was 62.2%, the specificity was 62.8%; P < 0.001] and by age [AUC = 0.625 (95% CI 0.532-0.719); the optimal cut-off value was 65.5 years: the sensitivity was 75.6%, the specificity was 60.1%; P < 0.001]. Conclusions:PLN or PCS density on chest scan and age are valuable in predicting the conversion from thoracoscopic lobectomy to thoracotomy for NSCLC patients. The combination of PET and CT has an additional role in predicting the conversion to thoracotomy during thoracoscopic lobectomy.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 534-538, 2021.
Article in Chinese | WPRIM | ID: wpr-910353

ABSTRACT

Objective:To discuss the problems existing in the implementation of the Chinese health industry standard WS 523-2019 by testing SPECT device.Methods:Under the WS 523-2019 standards, a total of 10 SPECT devices were tested with regard to their SPECT reconstructed spatial resolution (SRSR), system planar sensitivity (SPS), system spatial resolution (SSR), whole body system spatial resolution (WSSR), intrinsic uniformity (IU), intrinsic count rate performance (ICR), intrinsic spatial resolution (ISR) and intrinsic spatial linearity(ISL).Result:Under the requirements of WS 523-2019 standards for qualified limits, there are 3 devices with ISL unqualified and the rest of the performances qualified. The new standards basically can meet the clinical requirements and reflected the overall performance of SPECT.Conclusions:The distance between the radiation source and the surface of the detector has great influence on the spatial resolution.In the measurement of ISL, there must be a lead grid separately in the x and y directions. The lead grids with the parallel slits shall be positioned on the detector with the center slit centered on the detector. It is suggested to add rotation center in the new standards.

6.
Annals of Laboratory Medicine ; : 77-85, 2021.
Article in English | WPRIM | ID: wpr-874134

ABSTRACT

Background@#Thyroid diseases are highly prevalent worldwide, but their diagnosis remains a challenge. We established reference intervals (RIs) for thyroid-associated hormones and evaluated the prevalence of thyroid diseases in China. @*Methods@#After excluding outliers based on the results of ultrasound screening, thyroid antibody tests, and the Tukey method, the medical records of 20,303 euthyroid adults, who visited the Department of Health Care at Peking Union Medical College Hospital from January 2014 to December 2018, were analyzed. Thyroid-associated hormones were measured by the Siemens Advia Centaur XP analyzer. The RIs for thyroid-associated hormones were calculated according to the CLSI C28-A3 guidelines, and were compared with the RIs provided by Siemens. The prevalence of thyroid diseases over the five years was evaluated and compared using the chi-square test. @*Results@#The RIs for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3), total thyroxine (TT4), and total triiodothyronine (TT3) were 0.71–4.92 mIU/L, 12.2–20.1 pmol/L, 3.9–6.0 pmol/L, 65.6–135.1 nmol/L, and 1.2–2.2 nmol/L, respectively. The RIs of all hormones except TT4 differed significantly between males and females. The RIs of TSH increased with increasing age. The prevalence of overt hypothyroidism, overt hyperthyroidism, subclinical hypothyroidism, and subclinical hyperthyroidism was 0.5% and 0.8%, 0.2% and 0.6%, 3.8% and 6.1%, and 3.3% and 4.7% in males and females, respectively, which differed from those provided by Siemens. @*Conclusions@#Sex-specific RIs were established for thyroid-associated hormones, and the prevalence of thyroid diseases was determined in the Chinese population.

7.
Annals of Laboratory Medicine ; : 381-387, 2019.
Article in English | WPRIM | ID: wpr-739134

ABSTRACT

BACKGROUND: Accurate serum total thyroxine (TT4) measurement is important for thyroid disorder diagnosis and management. We compared the performance of six automated immunoassays with that of isotope-diluted liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) as the reference method. We also evaluated the correlation of thyroid stimulating hormone (TSH) with TT4 measured by ID-LC-MS/MS and immunoassays. METHODS: Serum was collected from 156 patients between October 2015 and January 2016. TT4 was measured by immunoassays from Abbott (Architect), Siemens (ADVIA Centaur XP), Roche (E601), Beckman-Coulter (Dxi800), Autobio (Autolumo A2000), and Mindray (CL-1000i), and by ID-LC-MS/MS. Results were analyzed using Passing-Bablok regression and Bland-Altman plots. Minimum requirements based on biological variation were as follows: a mean bias of ≤4.5% and total imprecision (CV) of ≤3.7%. RESULTS: All immunoassays showed a correlation >0.945 with ID-LC-MS/MS; however, the slope of the Passing-Bablok regression line varied from 0.886 (Mindray) to 1.23 (Siemens) and the intercept from −12.8 (Siemens) to 4.61 (Mindray). Only Autobio, Beckman-Coulter, and Roche included the value of one in the 95% confidence interval for slope. The mean bias ranged from −10.8% (Abbott) to 9.0% (Siemens), with the lowest value noted for Roche (3.5%) and the highest for Abbott (−10.8%). Only Abbott and Roche showed within-run and total CV ≤3.7%. CONCLUSIONS: Though all immunoassays correlated strongly with ID-LC-MS/MS, most did not meet the minimum clinical requirement. Laboratories and immunoassay manufacturers must be aware of these limitations.


Subject(s)
Humans , Bias , Diagnosis , Immunoassay , Mass Spectrometry , Methods , Thyroid Gland , Thyrotropin , Thyroxine
8.
Chinese Critical Care Medicine ; (12): 240-245, 2018.
Article in Chinese | WPRIM | ID: wpr-703631

ABSTRACT

Objective To investigate the curative effect of lateral position ventilation combined with vibration sputum drainage on the patients with acute respiratory distress syndrome (ARDS). Methods A prospective randomized controlled trial was conducted. The patients with ARDS undergoing mechanical ventilation (MV) admitted to intensive care unit (ICU) of Linyi Central Hospital from January 2013 to June 2017 were enrolled, and they were divided into simple ventilation group and combined treatment group according to random number table. The patients in both groups received etiological treatment, protective ventilation strategy, sensitive antibiotics for anti-infection, and calefacient and humidifying treatment. The patients in the simple ventilation group received bilateral discontinuous alternative lateral position ventilation [pressure controlled ventilation (PCV), tidal volume (VT) ≤ 6 mL/kg, the inhaled oxygen concentration (FiO2) and positive end expiratory pressure (PEEP) was adjusted to maintain the airway plateau pressure (Pplat) ≤ 30 cmH2O (1 cmH2O = 0.098 kPa)], and those in the combined treatment group received lateral position ventilation combined with vibration sputum drainage, twice a day, 15 minutes each time. The parameters of respiratory function and inflammation as well as excretion of sputum before and after treatment were compared between the two groups, and the complication and prognosis were recorded. Results A total of 200 patients with ARDS were included, 4 patients were excluded because of severe pneumothorax, massive hemorrhage of the digestive tract, or elevated intracranial pressure, so 196 patients were finally enrolled in the analysis. There were 98 patients in the simple ventilation group and the combined treatment group, respectively. There were no significant differences in parameters of respiratory function and inflammation as well as excretion of sputum before treatment between the two groups. After treatment, the above parameters in both groups were improved, and the effect of combined treatment was more significant. Compared with the simple ventilation group, white blood cell count (WBC), procalcitonin (PCT), C-reactive protein (CRP) at 24 hours of treatment in the combined treatment group were significantly decreased [WBC (×109/L):9.1±1.6 vs. 11.8±3.6, PCT (μg/L): 14.5±2.4 vs. 22.7±3.2, CRP (mg/L): 32.2±6.3 vs. 67.2±7.2, all P < 0.01], the quantity of sputum excretion was significantly increased (mL: 49.3±12.5 vs. 36.8±11.8, P < 0.01); 72 hours after treatment, the oxygenation index (PaO2/FiO2) in the combined treatment group was significantly increased [mmHg (1 mmHg = 0.133 kPa): 278±28 vs. 238±39, P < 0.01], and PEEP, FiO2, airway resistance (Raw) were significantly lowered [PEEP (cmH2O): 5±2 vs. 7±3, FiO2: 0.40±0.11 vs. 0.49±0.12, Raw (cmH2O): 12.8±0.7 vs. 16.2±0.8, all P < 0.01]. There was no significant difference in static lung compliance (Cst) or Pplat between the two groups. Compared with the simple ventilation group, the duration of MV (days: 5.5±3.0 vs. 8.6±2.1), the length of ICU stay (days: 7.5±5.4 vs. 11.3±4.6) and the extraction time of artificial airway (days: 6.6±2.8 vs. 9.4±3.3) in the combined treatment group were significantly shortened (all P < 0.01). However, there was no significant difference in the 28-day mortality rate [4.1% (4/98) vs. 3.1% (3/98)], the rate of tracheotomy [2.0% (2/98) vs. 3.1% (3/98)] or the incidence ofⅠ-Ⅱ skin pressure sore [1.0% (1/98) vs. 2.0% (2/98)] between simple ventilation group and the combined treatment group (all P > 0.05). No artificial airway disappearance, pneumothorax, grade Ⅲ or Ⅳ pressure sore was found in the two groups. Conclusions Compared with lateral position ventilation alone, the treatment of combined with vibration sputum drainage is more effective for improving the respiratory function of patients with ARDS, reducing infection action, shortening the duration of MV and the length of ICU stay, and improve the recovery, promote the rehabitation of patients.

9.
Chinese Journal of Clinical Laboratory Science ; (12): 462-466, 2018.
Article in Chinese | WPRIM | ID: wpr-694858

ABSTRACT

Objective To investigate the changes of prevalence of hyperuricemia ( HUA) and its correlations with blood glucose and lipid in healthy adults receiving physical examination at Peking Union Medical College Hospital (PUMCH) from 2012 to 2017. Meth-ods An observational approach was adopted for the data analysis.The test results of uric acid (UA),fasting blood glucose (FBG),to-tal cholesterol (TC),triacylglycerol (TG),low density lipoprotein cholesterol (LDL-C),high density lipoprotein cholesterol (HDL-C), creatinine (Cr) and Urea of 399 089 cases (206 881 males and 192 208 females) at PUMCH from January 2012 to December 2017 were collected and statistically analyzed.Results The total prevalence of HUA was 17.4% in which the prevalence of males was signif-icantly higher than that of females (25.6% vs 8.5%,χ2=20 234.850,P<0.01).During the years of 2012 to 2017,the prevalence of HUA was 26.5%,24.7%,28.6%,23.9%,24.8% and 24.5% in males,and 13.8%,6.3%,7.9%,6.1%,6.2% and 6.8% in females for each year respectively.The prevalence of HUA in males aged 18 to 64 years old was significantly higher than that in the age-matched fe-males (all P<0.05).However, the prevalence of HUA in males aged≥65 years old was similar to the age-matched females.There was no statistically significant difference of HUA prevalence between males and females aged ≥65 in 2013,2015,2016 and 2017 ( χ2=1.792,0.017,1.440 and 0.205 respectively;all P>0.05).The percentages of hyperlipidemia in both males and females of HUA group were higher than those of non-HUA group respectively (all P<0.01).The percentage of hyperglycemia in males of non-HUA group was higher than that of HUA group,but the percentage of hyperglycemia in females of non-HUA group was lower than that of HUA group ( all P<0.01).High levels of TC,TG and FBG were risk factors of HUA with increased OR values in increased concentrations of TC,TG and FBG,respectively.Conclusion During the recent 6 years, in healthy adults receiving physiced examination at PVMCH, the preva-lence of male HUA diagnosed was at overall high level,but the prevalence of female HUA was in decreasing and relatively stable trend. Hyperlipidemia and hyperglycemia should be the risk factors of HUA.

10.
Chinese Journal of Laboratory Medicine ; (12): 208-213, 2018.
Article in Chinese | WPRIM | ID: wpr-712128

ABSTRACT

Objective To evaluate the analytical performance of four lipoprotein associated phospholipase A2(Lp-PLA2)activity reagents on Beckman AU5800 automatic biochemical analyzer. Methods The remaining serum samples of 214 patients and 140 apparently healthy individuals were collected from March to July 2017 in Peking Union Medical College Hospital.These samples were used for method comparison and reference interval evaluation.According to the guidelines of EP15-A,EP6-A,EP-17 and EP7-P from Clinical and Laboratory Standards Institute(CLSI)standards,the precision, linearity, sensitivity and common interferences(e.g free bilirubin, conjunct bilirubin, hemoglobin and chyle)were assessed.According to EP9-A2,method comparisons of differents regents(Evermed,DiaSys,Hengxiao and Zhongyuan were labeled as A,B,C and D,respectively)were conducted and the differences were estimated at medical decision levels(328U/L,391U/L and 485U/L).Results The precision of four reagents were acceptable.The repeatability(CV%)of A to D were 0.5%-1.7%, 0.7%-3.0%, 0.9%-2.0% and 0.5%-3.3%,respectively.The reproducibility(CV%)were 0.7%-2.9%, 1.4%-3.2%, 1.3%-1.9%and 0.8%-4.1%,respectively.Both of those achievedlaboratory defined quality objective(<5%).The linearity of A to D were 44 -1 992 U/L,39 -1 798 U/L,13 -540 U/L and 75-1 717U/L,respectively.The regression coefficient R2 was between 0.997 and 1.000, and the correlation coefficient(r)was between 0.998 and 1.000.The interference of chyle were acceptable among these four reagents andmet the manufacturer′s requirementsor clinical needs.In a low level of Lp-PLA2,bilirubin had an obvious interferenceonreagent C;B and C were negatively affected when the hemoglobin was 4.5 g/L; and D was positively affected when the hemoglobin was 2.45 g/L.The regression coefficients R2 of A,C,D compared with B were between 0.978 and 0.995,and the correlation coefficients(r)were between 0.989 and 0.998. The expected differences at medical decision levels ranged from -240 U/L to 113 U/L.For A to D,the Lp-PLA2 activity results of 131(93.6%), 140(100%), 82(58.6%), and 128(91.4%)cases were analysed within the manufacturer′s claimed reference intervals.Conclusion The precision and linearity of the four Lp-PLA2 activity detection reagents used in automatic biochemical analyzer are good, but the anti-interference ability needs to be improved.

11.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 195-198, 2018.
Article in Chinese | WPRIM | ID: wpr-708842

ABSTRACT

Objective To study the reliability of 99Tcm-(hydrazinonicotinamide (HYNIC)-BMS-200261) (tricine) (trisodium triphenylphosphine-3,3',3"-trisulfonate (TPPTS)) as a radiotracer for protease activated receptor-1 (PAR-1) expression in breast cancer.Methods Fifteen nude mice bearing MDA-MB-435,MDA-MB-231 and MCF-7 human breast cancer xenografts (5 mice for each cell line) with different PAR-1 expression were used for 99Tcm-(HYNIC-BMS-200261) (tricine) (TPPTS) γ imaging,and tumor/non-tumor (T/NT) ratios were obtained with region of interest (ROI) technique.Afterwards,the biodistribution of 99Tcm-(HYNIC-BMS-200261) (tricine) (TPPTS) was analyzed in tumor-bearing nude mice,and the radioactivity in tumor (percentage activity of injection dose per gram of tissue,%ID/g) was calculated.The immunostaining was performed to examine PAR-1 expression in tumor tissue and semi-quantitative analysis was used.One-way analysis of variance and Pearson correlation analysis were used to analyze data.Results At 2 h postinjection,the T/NT ratios were 3.03±0.32,2.27±0.25 and 1.51±0.13 respectively in nude mice bearing MDA-MB-435,MDA-MB-231 and MCF-7 xenografts;the tumor uptakes of 99Tcm-(HYNIC-BMS-200261)(tricine)(TPPTS) were (1.03±0.15),(0.56±0.14) and (0.30±0.06) %ID/g;PAR-1 expression levels were (17.22±2.71) %,(10.78± 1.95) % and (2.80± 1.18) %,respectively (F values:47.66,46.36,62.35,all P<0.05).The T/NT ratios and tumor uptake of 99Tcm-(HYNIC-BMS-200261) (tricine) (TPPTS) at 2 h post-injection were correlated with PAR-1 expression (r values:0.934 and 0.929,both P<0.05).Conclusions 99Tcm-(HYNIC-BMS-200261) (tricine) (TPPTS) imaging could be a noninvasive and effective method for monitoring PAR-1 expression in human breast cancer.

12.
Chinese Journal of Laboratory Medicine ; (12): 436-442, 2017.
Article in Chinese | WPRIM | ID: wpr-686691

ABSTRACT

Objective To validate the performance of six enzymatic glycated albumin reagents and evaluate their clinical application.Methods The performance of six enzymatic glycated albumin reagents(labled as A,B,C,D,E,F) from Beijing Jiuqiang Co, Beijing Lideman Co,Ningbomeikang Co, Beijing Haomai Co, Sichuan Maike Co and Asahi Kasei Co were assessed on Olympus AU5800 automatic biochemistry analyzer.According to the standard of CLSI,the precision,interference and linear correlation of these reagents were assessed.To assess the accuracy of GA% ,we used GA standard material whose value had been assigned using ID-LC/MS method provided by ReCCS.To do the method comparison and determine the consistency of assay, 50 fresh serum samples of T2DM outpatient and 80 fresh serum samples of apparently healthy people in Jan 2016 were tested using six kits.According to the EP28-A3C protocol, the reference range for GA%was validated in 122 apparently healthy individuals undertaking medical examination from January to February 2016 in PUMC.Results The precision,and the ability of anti-interference of the six reagents were good.The accuracy percentage deviation of six reagents was-19.3%-9.2%.The correlation coefficient of domestic reagents A to E and imported reagents F in the determination of GA% was 0.966-0.999, the average absolute bias was 7.0%-10.4%.The coincidence rate of A-E and F in determining abnormal GA% was between 88.5% and 96.9%.The coincidence rate was increased after switching to the reference range for preliminary clinical evaluation.Conclusion Six GA enzymatic kits used in automatic biochemical analyzer have high precision and strong anti-interference ability.Accuracy still needs to be improved.

13.
Chinese Journal of Clinical Oncology ; (24): 655-658, 2016.
Article in Chinese | WPRIM | ID: wpr-495116

ABSTRACT

Objective:To assess the accuracy of the European Organization of Research and Treatment of Cancer (EORTC) Risk Tables in predicting the prognosis of patients with T1 non-muscle-invasive bladder cancer (NMIBC) treated in the Tianjin Medical University Can-cer Institute and Hospital (TMUCIH). The prognostic factors of T1 NMIBC are also explored, and a new risk scoring model suitable for T1 NMIBC is determined. Methods:We retrospectively reviewed the clinicopathologic characteristics of 108 patients with T1 NMIBC who underwent transurethral resections in TMUCIH from January 2011 to June 2013. We scored patients based on the number of ad-verse factors. Afterwards, divided them into different risk groups by the limits determined using receiver operating characteristic curve (ROC) analysis, and created a new risk scoring model. Results:In a group of 108 patients, 90 (83%) were male and 18 were female (17%). The median age was 65 years old (ranging from 24 to 88). Furthermore, 21 patients (19.4%) had a recurrence and 11 cases (10.2%) progressed to muscle-invasive disease. Conclusion:The EORTC cannot accurately predict the recurrence and progressive rate of T1 NMIBC. The most important prognostic factors for recurrence were tumor size and prior recurrence rate. Tumor grade and prior recurrence rate are independent prognostic factors for tumor progression. The new risk scoring model is more accurate in predicting the recurrence risk and progression of T1 NMIBC.

14.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 251-253, 2015.
Article in Chinese | WPRIM | ID: wpr-482846

ABSTRACT

Objective To evaluate characteristics of CT and 18F-FDG PET/CT in pulmonary sclerosing hemangioma (PSH).Methods A retrospective study involving 12 patients (2 males,10 females;24-80 years old) confirmed as PSH by pathology from May 2012 to July 2014 was investigated.All patients underwent chest CT scan,including enhanced CT;and 5 cases underwent whole-body 18F-FDG PET/CT.All imaging data were collected and analyzed to find out a more effective diagnostic method.Results In 12 PSH patients,9 had single lesion,of which 4 involved left lung and 5 right lung.The rest 3 patients including 1 with two nodules located in the right lower lobe,and 2 with multiple nodules scattered in several lobes.Plain CT showed all lesions had uniformly isodensity,4 with calcification,3 with air meniscus sign.Contrast-enhanced CT examinations showed that the majority lesions were prominent enhancement and few moderate enhancement,all lesions showed vessel marginating sign and 6 with cystic and necrosis area.18F-FDG PET/CT examinations showed that the lesions displayed patchy pattern of mild to moderate uptake with SUVmax 2.2--4.0.Conclusions The characteristic CT features of PSH,especially the contrast-enhanced CT imaging,are important for diagnosis.18F-FDG PET/CT findings are extremely helpful in differentiating PSH from malignant lesions.

15.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 552-556, 2015.
Article in Chinese | WPRIM | ID: wpr-939432

ABSTRACT

@#Objective To observe the effects of intensive lower extremity motor control training on the motor function of lower extremity, balance and walking capability of stroke patients. Methods 40 stroke patients were randomized into the intervention group (n=20) and control group (n=20). Both groups received the routine rehabilitation, while the intervention group accepted the lower extremity motor control training in addition for 6 weeks. Before and after 6 weeks of treatments, they were assessed with Fugl-Meyer Assessment of lower extremity (FMA-L), Berg Balance Scale (BBS), Holden Functional Ambulation Category (FAC); their gaits were analysesd with footprint. Results Both groups improved significantly in scores of FMA-L, BBS, FAC and average step length, stride width, walking velocity (P<0.01) after treatment, and improved more in the intervention group than in the control group (P<0.05). Conclusion Intensive motor control training of lower extremity may promote the recovery of motor function of lower extremities, balance and walking ability of stroke patients.

16.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 552-556, 2015.
Article in Chinese | WPRIM | ID: wpr-464538

ABSTRACT

Objective To observe the effects of intensive lower extremity motor control training on the motor function of lower extremi-ty, balance and walking capability of stroke patients. Methods 40 stroke patients were randomized into the intervention group (n=20) and control group (n=20). Both groups received the routine rehabilitation, while the intervention group accepted the lower extremity motor con-trol training in addition for 6 weeks. Before and after 6 weeks of treatments, they were assessed with Fugl-Meyer Assessment of lower ex-tremity (FMA-L), Berg Balance Scale (BBS), Holden Functional Ambulation Category (FAC);their gaits were analysesd with footprint. Re-sults Both groups improved significantly in scores of FMA-L, BBS, FAC and average step length, stride width, walking velocity (P<0.01) after treatment, and improved more in the intervention group than in the control group (P<0.05). Conclusion Intensive motor control train-ing of lower extremity may promote the recovery of motor function of lower extremities, balance and walking ability of stroke patients.

17.
Chinese Journal of Medical Instrumentation ; (6): 398-401, 2011.
Article in Chinese | WPRIM | ID: wpr-325969

ABSTRACT

This paper presents a design of non-blood contacting pneumatic ventricle assistance device, which consisted of several parts, such as dual-cavity cardiac assistance cup, ventricle assistance controller, computer, vacuum pump, and air compressor. And the performance of the non-blood contacting pneumatic ventricle assistance device on mock circulation loop is introduced, which is very close to the normal cardiac output.


Subject(s)
Equipment Design , Heart Ventricles , Heart-Assist Devices
18.
Chinese Journal of Tissue Engineering Research ; (53)2007.
Article in Chinese | WPRIM | ID: wpr-594627

ABSTRACT

In recent years, with the discovery of neural stem cells in the adult nervous system, as well as the continuous research of stem cells, the applications of stem cells in the treatment of ischemic stroke have drawn a broad attention of academicians.A great number of experimental studies have shown that stem cells can improve the post-stroke neurological function to some extent.This indicate a good prospect for clinical application.At present, researches related to the treatment of ischemic stroke with stem cells concentrate mainly on two ways.The first is to treat ischemic stroke through the activating of endogenous neural stem cells, and the second is to treat ischemic stroke through the transplantation of exogenous neural stem cells.This study is designed to review the present research status of the application of various stem cells for the treatment of ischemic stroke in animals and clinical studies, and to analyze existing problems and uncertainties.

SELECTION OF CITATIONS
SEARCH DETAIL