Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Medical Ethics ; (6): 109-116, 2024.
Article in Chinese | WPRIM | ID: wpr-1012859

ABSTRACT

It takes a long time to repair the social damage caused by a major epidemic, which is both a rebuilding of social order and a long process of social psychology. How to reproduce the collective memory of major epidemic events through narration, start from the reality of the epidemic narrative to the should and finally back to practice, and use epidemic narrative as an educational means and carrier in ideological and political education, it will be a beneficial attempt to realize the unification of knowledge and practice in college students’ ideological and political education in the post-epidemic period. To integrate the epidemic narrative into the ideological and political education of college students, it is necessary to adhere to the mainstream ideological direction of the narrative, unblock the narrative channel, reasonably choose the narrative method and optimize the narrative content, adhere to student-oriented, and give full play to the educational function of students’ individual narration.

2.
Chinese Journal of Experimental Ophthalmology ; (12): 1097-1101, 2014.
Article in Chinese | WPRIM | ID: wpr-637429

ABSTRACT

Background It is essential to measure and assess the parameters of ocular anterior segment for refractive surgery in myopic eyes.Some different imaging devices can be used for biometric measurement of ocular anterior segment,but which is more accurate and convenient is still under investigation.Objective This study was to compare the anterior segment parameters in myopic eyes measured by anterior segment optical coherence tomography (AS-OCT),Orbscan topography and ultrasonic pachymetry (US).Methods One hundred and forty eyes of 70 myopic subjects with the diopter of-0.75 to-10.25 D,who intended to receive corneal refractive surgery in the Second Affiliated Hospital of Zhejiang University School of Medicine from November 2011 to May 2012,were retrospectively analyzed.Central corneal thickness (CCT) was measured using AS-OCT,Orbscan Ⅱ and US,respectively,and anterior chamber depth (ACD) was measured by AS-OCT and Orbscan Ⅱ,and the angle to angle (ATA) distance and corneal white-to-white corneal distance (WTW) were measured by AS-OCT and Orbscan Ⅱ,respectively.The parameters from different apparatuses were statistically compared.Results The mean CCT were (516.57±30.25) μm in AS-OCT,(523.68±31.87) μm in US and (514.69±38.40) μm in Orbscan Ⅱ,without significant difference among them (F =2.775,P =0.063).Then the patients were divided into three groups based on the US measurement of CCT (<500 μm group,500-569 μm group,and ≥ 570 μm group).In the <500 μm group,there was a significant difference in the CCT among the three methods (F =22.236,P =0.000),significant differences were found between AS-OCT and Orbscan Ⅱ,or Orbscan Ⅱ and US(both at P<0.05).In the 500-569 μm group,there was no significant difference in the CCT among the three methods (F =3.011,P =0.051).In the ≥ 570 μm group,there was a significant difference in the CCT among the three methods (F =4.133,P =0.021),a significant difference was found between AS-OCT and US(P<0.05),but there was no significant difference between AS-OCT and Orbscan Ⅱ (P>0.05).The ACD values measured by AS-OCT was (3.83±0.21) mm,which was higher than (3.75 ± 0.21) mm by Orbscan Ⅱ,with a significant difference between them (t =-8.520,P =0.000).In addition,the ATA value by AS-OCT (12.43 mm±0.74 mm) was higher than the WTW value (11.42 mm±0.33 mm) by OrbscanⅡ,with a significant difference between them(t=-18.088,P=0.000).Conclusions AS-OCT,US and Orbscan Ⅱ can offer accurate CCT value,and they can provide references to one another before refractive surgery.However,the ACD,ATA and WTW values by AS-OCT and Orbscan]Ⅱ have large differences.

3.
Progress in Biochemistry and Biophysics ; (12)2006.
Article in Chinese | WPRIM | ID: wpr-592953

ABSTRACT

Based on the conservation of nucleotides at splice sites, the characteristics of base composition and base correlation in the adjacent segment sequences, the distance between alternative donor or acceptor splice sites and the content of GC and TC near splice sites, the donor and acceptor splice sites for alternative and constitutive introns are predicted by use of the method of diversity measure combined with quadratic discriminant analysis. For alternative splice sites the total prediction accuracies are 87.9% and 89.9% for donors and acceptors respectively (with the chosen threshold -2). For constitutive splice sites the total accuracy are 92.8% and 94.3% for donors and acceptors respectively (with the chosen threshold -1).

SELECTION OF CITATIONS
SEARCH DETAIL