Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Nephrology ; (12): 951-955, 2021.
Article in Chinese | WPRIM | ID: wpr-911914

ABSTRACT

Objective:To evaluate the efficacy of angioplasty on percutaneous superior vena cava occlusion in hemodialysis patients with tunnel-cuffed catheter (TCC) under digital subtraction angiography (DSA) guidance.Methods:A total of 62 hemodialysis patients with TCC in the First Affiliated Hospital of Sun Yat-sen University from December 2017 to June 2020 were enrolled retrospectively. According to the patency of the superior vena cava, the patients were divided into experiment group ( n=20) and control group ( n=42) in this study. Hemodialysis patients with superior vena cava occlusion in the experiment group received angioplasty, including balloon angioplasty, stenting and sharp recanalization, and catheterization with TCC under DSA guidance, while hemodialysis patients without superior vena cava occlusion in the control group only underwent catheterization with TCC under DSA guidance. The 1-year TCC patency rate, postoperative TCC blood flow and treatment-related complications between the two groups were compared. Results:In the experiment group, a total of 11 patients were treated only by percutaneous transluminal angioplasty, while 9 patients were treated combined percutaneous transluminal angioplasty with stent placement. In addition, 3 patients underwent sharp recanalization of superior vena cava occlusion. A total of 9 stents and 29 balloons were used. The course of dialysis in experiment group was longer than that in control group ( P<0.05). There were no significant differences in the 1-year TCC patency rate (85.0% vs 95.2%, P>0.05), postoperative TCC blood flow [(257.83±16.55) ml/min vs (251.90±18.79) ml/min, P>0.05] and incidence of treatment-related complications (grade 1-2, 30.0% vs 35.7%, P>0.05) between the two groups, respectively. Patients in the two groups had none of serious operation-related complications, and only some patients had mild clinical manifestations, such as postoperative pain and bleeding at the puncture point. Conclusions:For patients with longer duration of hemodialysis and superior vena cava stenosis and occlusion treated with angioplasty, the clinical effect of TCC within one year is equivalent to that of hemodialysis patients without angioplasty.

2.
Chinese Journal of Microsurgery ; (6): 264-267, 2019.
Article in Chinese | WPRIM | ID: wpr-756325

ABSTRACT

Objective To investigate the anatomy characteristics of saphenous artery(SA) and its perforator vessels in mini pig,and to provide a new perforator flap animal model.Methods Between May,2018 and August,2018,6 7-months-old mini pigs weight 25 kilograms were sacrificed by blooding under general anesthesia.The bilateral external iliac arteries were injected with a mixture of latex-lead oxide mixture and underwent CT-scanning to provide 3-dimensional reconstruction.The origin,diameter,courses and distribution of the SA and perforators of both hind limbs were observed.Results One of the hind limbs was abandoned due to the leakage of perfusion fluid.The other 11 hind limbs were available.The femoral artery passed through the medial femoral muscle and sartorius muscle in the middle of thigh,and run between the medial femoral muscle and gracilis muscle above the knee.Below the knee,it run on the surface of the medial leg muscles.A number of small branches were distributed in the tarsal joint and calcaneus at the medial malleolus,and there were abundant communicating branches with the posterior tibial artery.The average length of SA was (14.86±0.76) mm.The outer diameters of SA at initiative,medial tibial condyle and medial malleolus were(1.73±0.15) mm,(1.50±0.12) mm and (1.30±0.13) mm,respectively.There were a total of 79 perforators which were identified,with a mean of (7.09±1.16) perforators per hind limbs.And the average outer diameter was 0.10-0.78 (0.40±0.13) mm.Conclusion The SA constantly exist with good outer diameter.The number of perforator is abundant.SA can be used as a reliable animal model for studying and training of perforator flap.

3.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 601-607, 2017.
Article in Chinese | WPRIM | ID: wpr-621433

ABSTRACT

[Objective] To investigate the clinical value of using prospective ECG-gating Helical protocol in whole aorta and coronary arteries CT angiography combined with low tube voltage,low contrast medium injection rate and dose technology.[Methods]A total of 60 patients (heart rate≤ 75 bpm and normal heart rhythm) with suspected aortic disease or post-operation were randomly divided into 2 groups:G1 (n =30;tube voltage:80 kV;contrast medium injection rate:3 mL/s;contrast medium dose:0.65 mL/kg)and G2 (n =30;tube voltage:120 kV;contrast medium injection rate:4 mL/s;contrast medium dose:1.2 mL/kg).The two groups underwent aorta angiography with prospective ECG-gating Helical protocol by using 320-detector CT.The mean CT values and standard deviation of aorta,coronaries and adjacent adipose tissue were measured,signal to noise ratio (signal-to-noise ratio,SNR)and contrast to noise ratio (contrast-to-noise ratio,CNR) were calculated.The subjective quality scoring of 3-d post-processing images were evaluated independently by 2 senior radiologists.The mean CT values and standard deviation of aorta,coronaries and adipose tissue,SNR,CNR,subjective quality scoring,contrast medium dose and radiation dose were compared and analyzed.[Results] The abnormal and normal rate of aorta in two groups were 83.33% (25/30),16.67% (5/30) and 86.67% (26/30),13.33%(4/30);while the abnormal and normal rate of coronary arteries in two groups were 43.33% (13/30),56.67% (17/30) and 53.33%(16/30),46.67% (14/30).SNR values of ascending aorta,descending aorta,abdominal aorta,superior mesenteric artery,bilateral renal artery,left main coronary artery,left anterior descending branch,left circumflex branch,right coronary artery and CNR values of abdominal aorta,superior mesenteric artery,bilateral renal artery,left anterior descending branch,left circumflex branch had no statistical significance,while the other indicators were significant differences between the two groups.The radiation dose and the contrast medium dose of G1 was significantly lower than G2 (P < 0.05).There was no difference in the subjective image quality of 3D post-processing images between the two groups (P > 0.05).[Conclusions] Using prospective ECG-gating Helical protocol in whole aorta and coronary arteries CT angiography combined with low tube voltage,low contrast medium injection rate and low contrast medium dose technology can help to reduce radiation and contrast medium dose without impacting on the imaging quality satisfactorily.

4.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 614-617, 2017.
Article in Chinese | WPRIM | ID: wpr-621429

ABSTRACT

[Objective] To observe the effect of computer-aided detection (CAD) system in improving lung nodule detection sensitivity and inter-observer variation.[Methods] 300 PA digital radiographs including 100 normal cases and 200 cases with pulmonary nodules confirmed by CT were enrolled.Two senior chest radiologists referenced CT images and marked the sizes and locations of all nodules with consensus as the gold standards.Four senior radiologists and four junior radiologists interpreted the digital chest radiographs independently without and with CADand recordtheir results.Pair t test and coefficient of variation (CV) was used to compare the difference of lung nodule detection sensitivity and inter-observer variation between withoutand with CAD.[Results] The mean lung nodule detection sensitivity of senior and junior radiologists withoutand with CAD were (41.1 ± 2.0)%,(28.0 ± 2.0)% and (45.0 ± 1.8)%,(39.2 ± 0.9)%,respectively,statistical analysis showed there was statistically significant difference.Moreover,CV of all radiologists without and with CAD were 20.9% and 8.1%.[Conclusion] Both lung nodule detection sensitivity and inter-observer variation of senior and junior radiologists can be improved by CAD.

5.
Chinese Journal of Microsurgery ; (6): 127-129, 2015.
Article in Chinese | WPRIM | ID: wpr-469312

ABSTRACT

Objective To investigate the effect of perforator identification before DIEP flap dissection for the patient with abdominal scar.Methods Preoperative multidetector-row computed tomography angiography was used to identify that the dominant perforators of the abdominal wall were not damaged completely.During the second stage breast reconstruction operation,the located dominant perforator and the DIEP flap were dissected.Results The dominant perforator located by MDCTA was identified with the exploration in operation.Follow-up for half a year,the flap survived well and the patient was satisfied with the appearance.Conclusion Abdominal scar was not the definite contraindication for DIEP flap.MDCTA provided a good quality evaluation of the perforator vessels.The located dominant perforator was dissected to confirm the blood supply of the DIEP flap.Identification of perforator can be used as a routine preoperative evaluation for patients with scar on donor site.

SELECTION OF CITATIONS
SEARCH DETAIL