Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiation Oncology ; (6): 52-56, 2009.
Article in Chinese | WPRIM | ID: wpr-397116

ABSTRACT

Objective To analyze the clinical outcome of concurrent ehemo-radiotherapy in stage Ⅳ non-small cell lung cancer(NSCLC).Methods From Jan.1997 to Dec.2006,214 patients with patho logically or cytologically proven stage Ⅳ NSCLC were included in this analysis.Of those patients,98 re ceived radiotherapy concurrently with 3-week cycle chemotherapy(group A),18 received radiotherapy con currently with weekly chemotherapy(group B) ,44 received chemotherapy alone,37 received radiotherapy a lone and 13 received sequential chemo-radiotherapy.The primary tumor was treated by three-dimensional conformal radiotherapy(3DCRT) or conventional radiotherapy with conventional fraefionation or late-course accelerated hyperfraction (LA H RT).Group A received 21-28 days cycle cisplatin-based chemotherapy (cis platin combined with PTX,DTY,NVB or Vp-16) ,and group B received weekly DDP combined with PTX or topteeon for 4-6 weeks.Results The follow-up rate was 99%.The 1-and 2-year overall survival rates of group A,group B,chemotherapy alone,radiotherapy alone and sequential chemo-radiotherapy were 41% and 11% ,16% and 0,31% and 7% ,34% and 10% ,26% and 3% ,respectively(x2 = 11.18,P=0.025).The patients with concurrent 3DCRT,LAHRT and radiotherapy dose≥70 Gy had better survival in group A than those in chemotherapy alone group.Patients who received≥2 cycles chemotherapy with concurrent radio therapy had longer survival time than those who had ≥2 cycles chemotherapy alone. Conclusions Con current chemotherapy and 3DCRT,LAHRT with the dose ≥70 Gy can improve the overall survival of patients with stage Ⅳ non-small cell lung cancer.

2.
Chinese Journal of Radiation Oncology ; (6): 57-60, 2009.
Article in Chinese | WPRIM | ID: wpr-397051

ABSTRACT

Objective To analyze the normal lung dose-volume histogram(DVH) varieties in the former and later period(P1 and P2)of three dimensional conformal radiation therapy(3DCRT) plans and the compound (Pc) plan in non-small cell lung cancer(NSCLC),and to access the feasibility to modify the target volume during the treatment course.Methods Twenty-one NSCLC patients who had received accelerated hyper-frationation 3DCRT in P2 were included in the study.Both of the P1 and P2 plans were redesigned to a total dose of 70 Gy with V20 smaller than 35%.When the target volume was modified and P2 plan was rede signed using accelerated hyper-frationation 3DCRT of 30 Gy after P1 plan of 40 Gy,the Pc plan was compoun ded by transmitting the parameters(such as target volume,irradiation field and dose) of P1 plan into P2 plan. Total lung volume and target volumes(GTV,PTV) of P1 and P2 were evaluated.MLD,V5,V10,V20 and V30 of P1,P2 and Pc were calculated.Results The total lung volume in P1 and P2 plans was not significantly dif ferent(t = 0.19,P = 0.850).The volumes of GTV,PTV in P2 were obviously smaller than P1 (t = 2.88,P = 0.009 ; t = 4.01 ,P = 0.001) .When comparing P2 with P1 ,MLD were 16.5 Gy Vs 17.8 Gy (t = 2.60, DOI:10.3760/cma.j.issn.1004-4221.2009.01.057 P = 0.017),V30 was significantly decreased (t = 2.19,P = 0.041),but V5,V10 and V20 had no significant difference.Similar differences were found in MLD,V5 ,V10 ,V20 and V30 when comparing Po to P1.P2 plans had significantly smaller MLD,Vs,V10,V20 and V30 than Pc plans.Fourteen patients with decreased PTV were further analyzed.The V30 and MLD decreased significantly (t = 3.00,P = 0.0 I 0;t = 2.38,P = 0.033), but V5 ,V10,V20 had no difference when comparing P1 and P2 plans.Among these 14 patients,the V10 and V30 decreased significantly(t = 2.76,P = 0.033 ; t = 3.60,P = 0.011) when P2 plans were generated using the same field number and beam angles in P1 plans in 7 patients.The parameters were similar in P1and Pc plans,but increased significantly when comparing to P2.Various parameters were the same among P1,P2 and Pc plans when P2 plans were designed using 1-2 different fields and angles in the other 7 patients.The differ ences were not significant between P1 and P2 plans in 7 patients with the same or increased PTV.Expansion or contraction of PTV significantly influenced MLD and V2o (r =-0.62,P = 0.03 ; r = O.48,P = 0.029). Conclusions When the tumor regresses,the high dose volume of the lung decreases with modifying the tar get volume and replanning in the later period using accelerated hyper-frationation 3DCRT.The low dose vol ume of the lung may decrease if the field orientations are same throughout the treatment.It is rational to eval uate the normal lung DVH of the whole plan when the physical parameters of the later period plan are the same as the former one.

SELECTION OF CITATIONS
SEARCH DETAIL