Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Chinese Medical Journal ; (24): 68-71, 2013.
Article in English | WPRIM | ID: wpr-331320

ABSTRACT

<p><b>BACKGROUND</b>Early detection with screening mammography can potentially reduce breast cancer mortality rates. To achieve an efficient screening, a peer review system provides a compensatory double-check reviewing, will hopefully to prevent the omission of detectable lesions and reduce unnecessary recall.</p><p><b>METHODS</b>In 2009, 4643 initial mammographic screenings reported by 74 screening radiologists had negative results with a recall rate of less than 5%. In the same year, 2538 initial positives screened by 18 screening radiologists had a recall rate higher than 15%. Those 7181 randomized screenings were evenly distributed for reassessment by 39 reviewing radiologists. The disagreement of assessments between the reviewers and screening radiologists was recorded. The differential rate was defined as the number of the disagreements divided by the number of audited films reviewed by a screening radiologist. The equality of the differential rates for each screening radiologists with negative and positive assessments was compared by a Chi-square test. The performance of the 39 auditors was measured by the Kendall's tau statistic. P values less than 0.05 were considered statistically significant.</p><p><b>RESULTS</b>The mean differential rate for screening radiologists of negative assessments was 6.7% (P = 0.588), while 35.0% for positive assessments were significant (P < 0.001). The result indicated that most of the initial negative assessments reported by the screening radiologists were generally accepted by the reviewers but not the positive assessments. With respect to the 39 reviewers, there was no significant evidence for the association of the difference rates between negative and positive assessments. Nine reviewers were found to have their differential rate for negative and positive assessments larger than the average of the population. Eleven reviewers were found to have their differential rates smaller than the average for both. Thirteen reviewers had their differential rates smaller than the average for negative assessments but larger than the average for positive assessments. The opposite condition was found for six reviewers. The Kendall's tau statistic was 0.038 (P = 0.735).</p><p><b>CONCLUSIONS</b>Reviewers usually agreed with the opinion of the initial screening doctors who reported negative findings. Therefore, a 5% recall rate as the lower range of reviewing negatives may be still too high. The recall rate of more than 15% was significantly related to improper interpretation, especially when the differential rate is 25% or higher, a warning to the underperforming screening radiologist is recommended. An ideal reviewer should interpret films independently. Reviewers with tendencies to be followers or contrarians should not be enrolled in the reviewing system.</p>


Subject(s)
Female , Humans , Breast Neoplasms , Diagnostic Imaging , Early Detection of Cancer , Mammography , Peer Review , Reproducibility of Results , Taiwan
2.
Korean Journal of Radiology ; : 70-80, 2013.
Article in English | WPRIM | ID: wpr-44593

ABSTRACT

OBJECTIVE: The current study retrospectively evaluated whether the percutaneous N-butyl cyanoacrylate (NBCA) seal-off technique is an effective treatment for controlling the angioplasty-related ruptures, which are irresponsive to prolonged balloon tamponade, during interventions for failed or failing hemodialysis vascular accesses. MATERIALS AND METHODS: We reviewed 1588 interventions performed during a 2-year period for dysfunction and/or failed hemodialysis vascular access sites in 1569 patients. For the angioplasty-related ruptures, which could not be controlled with repeated prolonged balloon tamponade, the rupture sites were sealed off with an injection of a glue mixture (NBCA and lipiodol), via a needle/needle sheath to the rupture site, under a sonographic guidance. Technical success rate, complications and clinical success rate were reported. The post-seal-off primary and secondary functional patency rates were calculated by a survival analysis with the Kaplan-Meier method. RESULTS: Twenty ruptures irresponsive to prolonged balloon tamponade occurred in 1588 interventions (1.3%). Two technical failures were noted; one was salvaged with a bailout stent-graft insertion and the other was lost after access embolization. Eighteen accesses (90.0%) were salvaged with the seal-off technique; of them, 16 ruptures were completely sealed off, and two lesions were controlled as acute pseudoaneurysms. Acute pseudoaneurysms were corrected with stentgraft insertion in one patient, and access ligation in the other. The most significant complication during the follow-up was delayed pseudoaneurysm, which occurred in 43.8% (7 of 16) of the completely sealed off accesses. Delayed pseudoaneurysms were treated with surgical revision (n = 2), access ligation (n = 2) and observation (n = 3). During the follow-up, despite the presence of pseudoaneurysms (acute = 1, delayed = 7), a high clinical success rate of 94.4% (17 of 18) was achieved, and they were utilized for hemodialysis at the mean of 411.0 days. The post-seal-off primary patency vs. secondary patency at 90, 180 and 360 days were 66.7 +/- 11.1% vs. 94.4 +/- 5.4%; 33.3 +/- 11.1% vs. 83.3 +/- 8.8%; and 13.3 +/- 8.5% vs. 63.3 +/- 12.1%, respectively. CONCLUSION: Our results suggest that the NBCA seal-off technique is effective for immediate control of a venous rupture irresponsive to prolonged balloon tamponade, during interventions for hemodialysis accesses. Both high technical and clinical success rates can be achieved. However, the treatment is not durable, and about 40% of the completely sealed off accesses are associated with developed delayed pseudoaneurysms in a 2-month of follow-up. Further repair of the vascular tear site, with surgery or stent-graft insertion, is often necessary.


Subject(s)
Aged , Female , Humans , Male , Aneurysm, False/etiology , Angioplasty, Balloon/adverse effects , Arteriovenous Shunt, Surgical/adverse effects , Enbucrilate/administration & dosage , Ethiodized Oil/administration & dosage , Graft Occlusion, Vascular/etiology , Renal Dialysis , Retrospective Studies , Rupture , Survival Analysis , Treatment Outcome , Ultrasonography, Interventional , Vascular Patency
3.
Korean Journal of Radiology ; : 259-268, 2013.
Article in English | WPRIM | ID: wpr-15361

ABSTRACT

OBJECTIVE: To evaluate the clinical efficacy as well as long-term clinical outcomes of superselective microcoil embolization for lower gastrointestinal bleeding (LGIB). MATERIALS AND METHODS: Between 1997 and 2009, 26 patients with intended transcatheter embolotherapy for LGIB were retrospectively reviewed. Embolization was performed only when the catheter could be advanced to or distal to the mesenteric border of the bowel. The main purpose of our study was to assess technical success, recurrent bleeding rate and complications. We also evaluated the long-term clinical outcome, including late recurrent LGIB, bowel ischemia and the survival rate. RESULTS: Twenty-two bleeding sources were in the territory of superior mesenteric artery and four in the inferior mesenteric artery. Technical success was achieved in 22 patients (84.6%). The target vessel of embolization was vasa recta in seventeen patients and marginal artery in the remaining five patients. Early rebleeding occurred in two patients (7.7%) and bowel ischemia in two patients, of whom the embolized points were both at the marginal artery. Delayed recurrent bleeding (> 30 days) occurred in two angiodysplasia patients. Five patients (19.2%) died within the first 30 days of intervention. Long-term follow-up depicted estimated survival rates of 58.2 and 43.1% after one, and five years, respectively. CONCLUSION: Transcatheter embolotherapy to treat LGIB is effective with low rebleeding and ischemic complications. Considering the advanced age and complex medical problems of these patients, the minimal invasive embolotherapy may be used as both a primary and potentially definitive treatment of LGIB.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Acute Disease , Colonoscopy , Embolization, Therapeutic/adverse effects , Endpoint Determination , Gastrointestinal Hemorrhage/diagnostic imaging , Recurrence , Retrospective Studies , Survival Rate , Tomography, X-Ray Computed , Treatment Outcome
4.
Korean Journal of Radiology ; : 588-588, 2010.
Article in English | WPRIM | ID: wpr-80606

ABSTRACT

The publisher and authors would like to draw the reader's attention to an error in the following article. The Usefulness of Fast-Spin-Echo T2-Weighted MR Imaging in Nutcracker Syndrome: a Case Report. Korean J Radiol 2010;11:373-377. On page 373, the first author's name has been incorrectly spelled as Heong-Leng Wong. The correct spelling is Heong-Ieng Wong.

5.
Korean Journal of Radiology ; : 373-377, 2010.
Article in English | WPRIM | ID: wpr-183829

ABSTRACT

Nutcracker syndrome occurs when the left renal vein (LRV) is compressed between the superior mesenteric artery and the aorta, and this syndrome is often characterized by venous hypertension and related pathologies. However, invasive studies such as phlebography and measuring the reno-caval pressure gradient should be performed to identify venous hypertension. Here we present a case of Nutcracker syndrome where the LRV and intra-renal varicosities appeared homogeneously hyperintense on magnetic resonance (MR) fast-spin-echo T2-weighted imaging, which suggested markedly stagnant intravenous blood flow and the presence of venous hypertension. The patient was diagnosed and treated without obtaining the reno-caval pressure gradient. The discomfort of the patient lessened after treatment. Furthermore, on follow-up evaluation, the LRV displayed a signal void, and this was suggestive of a restoration of the normal LRV flow and a decrease in LRV pressure.


Subject(s)
Adult , Humans , Male , Young Adult , Abdominal Pain/etiology , Constriction, Pathologic , Diagnosis, Differential , Follow-Up Studies , Kidney Diseases/complications , Magnetic Resonance Imaging/methods , Renal Veins/pathology , Stents , Syndrome , Vascular Diseases/complications
6.
Korean Journal of Radiology ; : 118-124, 2006.
Article in English | WPRIM | ID: wpr-7169

ABSTRACT

OBJECTIVE: We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. MATERIALS AND METHODS: Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patients (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8-10mm in diameter and 40-80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. RESULTS: No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates (+/- standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69% +/- 9 and 88% +/- 6, 41% +/- 10 and 88% +/- 6, 30% +/- 10 and 77% +/- 10, and 12% +/- 8 and 61% +/- 13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51% +/- 16 and 86% +/- 13 vs 45% +/- 15 and 73%+/-13 at 6 months, and 25% +/- 15 and 71% +/- 17 vs 23% +/- 17 and 73% +/- 13 at 12 months (p = .346 and .224), respectively. CONCLUSION: Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen.


Subject(s)
Middle Aged , Male , Humans , Female , Aged, 80 and over , Aged , Vascular Patency , Treatment Failure , Stents , Renal Dialysis , Polytetrafluoroethylene , Metals , Graft Occlusion, Vascular/therapy , Forearm , Arteriovenous Shunt, Surgical , Angioplasty, Balloon
SELECTION OF CITATIONS
SEARCH DETAIL