Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 3041-3044, 2016.
Article in Chinese | WPRIM | ID: wpr-504207

ABSTRACT

Objective To explore the security and its influencing factors on benign airway stenosis treated with interventional of high pressure balloon expansion catheter.Methods Clinial data of 39 cases of inpatients suffered from benign airway stenosis were chosen.17 cases were male,and 22 cases were female.The ages of them ranged from 15 to 83 years old.According to the clinical symptoms,HRCT 3D reconstruction,and the results of bron-choscope,all patients were treated with balloon expansion catheter at different criterions.The balloon catheter with size that slightly smaller than the targeted normal bronchial tube was chosen,expansion for average 1 -4 times,single balloon expansion time ranged from 0.5 to 4 min,the pressures were kept at 3 -6 atmosphere,and the highest pres-sure did not exceed 8 atmospheric pressure.The efficacy and complications were retrospectively analyzed.Results 19 cases were completely effective,14 cases were basically effective,6 cases were completely ineffective,and the total effective rate was 84.6% (33 /39 ),the incidence of complications was 35.8% (14 /39 ),moreover,no deaths occurred.Conclusion High pressure balloon catheter expansion is one of commonly used technology in breathing interventional treatment;it has the characteristics of easy operation,and immediate curative effect,and so on.But if the improper operation,incorrect selection of the case,or inaccurate evaluation of the stenosis during operation,serious complications and unnecessary iatrogenic injury can be occurred.Therefore,it is worthy of attention and further summarizing by breathing interventional physicians.

2.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 2747-2749,2750, 2015.
Article in Chinese | WPRIM | ID: wpr-602618

ABSTRACT

Objective To preliminaryly explore the effect and adverse reaction of Marine Injection combined therapy through local spray in benign tracheobronchial stenosis.Methods 19 cases of bronchial tuberculosis were collected in our department.By assessing cough,shortness of breath and other symptoms,chest high -resolution CT (HRCT)of three -dimensional reconstruction,and length were observed by ultrafine bronchial stenosis.According to the pathogeny and types of stenosis,combined multiple intervention were sequentially adopted,and then Marine Injec-tion was sprayed through one -off endoscopic spray tube.All the subjects were divided into the two groups,the higher concentration Marine injection (1 200 mg/mL)group was chosen with the condition of serious inflammation,edema, ulcer and necrosis,obvious local granulation tissue hyperplasia,severe scar stenosis,and the length of stenosis greater than 2 cm or the sectional area of stenosis less than 50% of the normal sectional area,otherwise the low concentration (600 mg/mL)group was chosen.The subjects were reexamined by clinical symptoms,high -resolution CT (HRCT) of three -dimensional reconstruction,and ultrafine bronchoscopy a week after the surgery to dynamically observe the local changes.Depending on the situation,the injection was sprayed once a week,adding up to 2 -4 times.Follow -up visit lasted for 3 months,cough,expectoration or hemoptysis,and dyspnea were observed.Results 11 cases were effective fully,17 cases were effective substantially,7 cases were ineffective,the total effective rate was 80% (28 /35).The overall complication rate was 42.8% (15 /35),no deaths occurred.No complications related to local spra-ying of Marine were seen.Conclusion Local spray of Marine Injection may have preferable effect that inhibits scar formationand prevention airway restenosis.It is worth further study with a high security,precise clinic effect,easy oper-ation and etc.

3.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1281-1283, 2015.
Article in Chinese | WPRIM | ID: wpr-470432

ABSTRACT

Objective To retrospectively analyze of clinical application of BF-XP60 micro-bronchoscopy.Methods 135 clinical data of patients who adopted ultrafine micro-bronchoscopy and intervention were collected and analyzed for the complications.Results The frequency of local rhinomusoca damaging and errhysis was in 3 cases,the mucous of the glottis damaging and errhysis was in 2 cases,local mucous of the tracheal bronchus errhysis was in 3 cases.After intervention,the frequency of fever was in 13 cases,massive haemorrhage was in 1 case,pneumothorax was in 1 case,chest pain was in 2 cases,part fiber of inner untrafine micro-bronchoscopy broken was in 2 cases,check failure due to ultrafine micro-bronchoscopy broken in trachea was in 4 cases,and arrhythmia,asphyxia,and death were in 0 case.The overall incidence of side effects was 22.9% (31/135).Conclusion Application of ultrafine micro-bronchoscopy was contributed to find the lesions within the bronchioles and around the lungs,moreover,it could evaluate the distal bronchus of airway obstruction which was planned to adopt intervention.The topic that how to reduce the incidence of the side effects of the micro-brohchoscopy and improve the success rate and safety of inspection and intervention was worth to be concerned.

4.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 3054-3056, 2014.
Article in Chinese | WPRIM | ID: wpr-456908

ABSTRACT

Objective To retrospectively analyze the effect of two kinds of biological agents in volume -re-duced bullae .Methods 11 patients who suffered from bullae were operated under large C-arm locating ,and infused two kinds of biological agents through micro catheter of fibreoptic bronchoscopy .All of them were randomly divided into the two groups .The biological agents in group A were fibrinogen and diluent thrombin , and that of group B was Porcine Fibrin Sealant Kit .In group A,the micro catheter with diameter of micro thread less than 1.2mm was placed in bullae through fibreoptic bronchoscope ,and then the 2mL lidocaine,5 ml fibrinogen,and double of 500u diluent thrombin were inproperorder injected through micro catheter .In group B,the Porcine Fibrin Sealant Kit was injected at the same method,and then the suspension fluid was exacted .The operation time was recorded ,and then the clinical efficacy and incidence rate of complications were compared .Results The operation time of group A was 5-15 minutes, and that of group B was 6-20 minutes.For all the patients ,4 cases were totally effective ,2 cases were significantly effective,and 2 cases were totally non-effective.The total effective rate was 81.82%(9/11).The incidence rates of common complications in group A and B were 52.38%(22/42),58.33%(14/24),respectively,the difference was not significant (χ2 =0.22,P>0.05).Moreover,there were no serious complications in all cases .Conclusion The security and effect of two kinds of biological agents might be well enough ,but in view of less cases ,they were worth to further popularized and applied in clinical practice .

SELECTION OF CITATIONS
SEARCH DETAIL