Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Perinatal Medicine ; (12): 594-599, 2020.
Article in Chinese | WPRIM | ID: wpr-871111

ABSTRACT

Objective:To investigate the characteristic of ultrasound in diagnosing fetal intestinal volvulus.Methods:From April 2015 to May 2018, four cases of fetal intestinal volvulus indicated by prenatal ultrasound in the Affiliated Hospital of Jining Medical College and confirmed either by autopsy or by postnatal surgery, were retrospectively analyzed. A total of 11 ultrasound scans had been performed on the four cases, and the dynamic and static ultrasound features were summarized. Pregnancy outcomes and concomitant malformations were also followed up. Descriptive statistical analysis was used.Results:The direct ultrasonographic patterns of intestinal volvulus in the four cases were "whirlpool" signs (six times), clockwise wrapping of branch vessels of the superior mesenteric vein and the superior mesenteric artery (five times), and "coffee bean" sign (three times); the indirect signs included dilated small intestine (11 times), ascites (eight times), polyhydramnios (five times), peritoneal calcification(four times), pseudocysts(once). Out of the 11 ultrasound examinations, early-stage volvulus was detected on three occasions, all with "whirlpool" signs and clockwise wrapping of branch vessels of the superior mesenteric vein and the superior mesenteric artery. As the disease progressed to the meconium peritonitis stage, indirect signs emerged while the initial two signs can diminished. Postnatal surgery or autopsy after labor induction confirmed the segmental volvulus in the four cases, of which three were complicated by intestinal atresia. No intestinal malrotation was found.Conclusion:Typical direct signs and atypical indirect signs could be identified in the sonogram findings of fetal volvulus, and are important for diagnosing fetal volvulus.

2.
Chinese Journal of Immunology ; (12): 558-562,573, 2017.
Article in Chinese | WPRIM | ID: wpr-606680

ABSTRACT

Objective:To prepare nanobody-based immunotoxin BI7D12-PE38KDEL targeting EGFR and to examine its cytotoxicity against EGFR positive tumor cells.Methods:By using molecular cloning strategy,prokaryotic expression construct of pET28a-BI7D12-PE38KDEL was generated which consisted of nanobody 7D12 targeting EGFR in the form of a divalent fused with PE38KDEL,a truncated form of pseudomonas exotoxin A via a flexible peptide(G4S)4,and then transformed into E.coli BL21(DE3).Protein expression was induced by adding IPTG,purified by Ni-affinity column chromatography,and verified by Western blot.The binding capacity of the resulted immunotoxin to EGFR-positive cells A549,HT29,MCF-7 and EGFR-negative cells CEM,Jurkat were determined by flow cytometry assay,and its cytotoxicity against the target cells was examined.Briefly,tumor cells were treated with different dosage of the immunotoxin,and the killing efficacy of BI7D12-PE38KDEL on these cells were assessed by WST-1 assay after 72 hours.Results:The SDS-PAGE and Western blot results showed the recombinant immunotoxin BI7D12-PE38KDEL was successfully prepared,and majority of them was expressed in soluble form.BI7D12-PE38KDEL could selectively bind to EGFR-positive cells of A549,HT29,and MCF-7.More importantly,the immunotoxin exhibited much more significant killing effect on these EGFR positive cells compared to the negative control group of CEM and Jurkat cells(P<0.01).Conclusion:In the current study,the nanobody-based immunotoxin BI7D12-PE38KDEL targeting EGFR was successfully prepared and exhibited a superior inhibition effect for the growth of EGFR-positive cells.

3.
Cancer Research and Clinic ; (6): 605-608, 2013.
Article in Chinese | WPRIM | ID: wpr-442246

ABSTRACT

Objective To investigate the feasibility and potential advantages of RapidArc applied to the radiotherapy of the postoperative rectal cancer.Methods 8 postoperative patients with rectal cancer were selected to be treated with a dose of 50Gy in fraction of 2Gy every time and 5 times a week.IMRT and RapidArc were used respectively to compare different target conformities,homogeneity index,dose-volume histogram data,treatment times and monitor units.Results The conformal index by RapidArc was 0.89±0.02 which was better than those by 5F-IMRT,0.87±0.02 (t =3.286,P < 0.05),while the homogeneity index of target volume (1.060±0.005) and average dose [(52.55±0.76) Gy] by RapidArc were a little less than the homogeneity index of target volume (1.064±0.007) and average dose [(52.90±0.82) Gy] by 5F-IMRT (t =-1.459,-1.000,P > 0.05).The exposure dose and mean dose of bladder and small bowel in high dose region by RapidArc were lower than those by 5F-IMRT,as well as bone marrow.The differences were statistical significant (P < 0.05).The monitor units by RapidArc and by 5F-IMRT were (631±68) MU and (1046±146) MU,respectively (t =-5.830,P < 0.05),while the mean treatment times were (78±5) s and (348±29) s,respectively (t =-26.358,P < 0.05).Conclusion Compared with 5F-IMRT,RapidArc improves the target conformities and lowers the exposure dose for the organs at risk in high dose region while using fewer monitor units and less treatment time,which helps comforting patients and improving the efficiency.

4.
Chinese Journal of Dermatology ; (12): 738-740, 2013.
Article in Chinese | WPRIM | ID: wpr-442094

ABSTRACT

Objective To evaluate the effectiveness and safety of a sodium hyaluronate-containing dressing for skin wound healing after Q-switched laser therapy.Methods Sixty-six patients with facial pigmentary disorders were enrolled in this study.After treatment with Q-switched laser,the patients were randomly and equally divided into three groups to apply a sodium hyaluronate-containing dressing,a thermal spring water-containing facial mask and a distilled water-containing facial mask respectively.The dressing or facial masks were externally applied to the face for 15 minutes once immediately after the laser therapy,then,once every night for 14 consecutive days.Inflammatory responses,such as erythema,edema and burning sensation,were measured semi-quantitatively on day 1,3,7 and 14 separately after the laser therapy.The time for skin wound healing and degree of patients' satisfaction were compared among these groups by chi-square test and rank sum test,respectively.Results The sodium hyaluronate-containing dressing and thermal spring watercontaing facial mask were superior to the distilled water-containing facial mask in the improvement of erythema,edema and burning sensation after the laser therapy (all P < 0.05).Compared with the patients applying the thermal spring water-containg facial mask and those applying the distilled water-containing facial mask,those applying the sodium hyaluronate-containing dressing felt better,with significantly increased skin cleanliness,humidity,smoothness,confort degree and overall satisfaction (all P < 0.05).Conclusion The sodium hyaluronate-containing dressing is effective for improving acute inflammatory responses and increasing skin cleanliness,humidity and smoothness after laser therapy.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 282-285, 2013.
Article in Chinese | WPRIM | ID: wpr-434858

ABSTRACT

Objective To compare the dosimetric differences between two plans of RapidArc and 5F-IMRT for breast cancer radiotherapy after breast-conserving surgery.Methods Eight female patients with left-sided breast cancer after breast-conserving surgery were selected.A dose of 50 Gy in 25 fractions was prescribed for plans of RapidArc and 5F-IMRT.Target conformity index (CI),homogeneity index (HI),target coverage,exposure dose volume delivered to organ at risk were compared between two plans.At the same time,treatment delivery time and monitor units (MU) were also compared.Results The target conformity index (CI) in RapidArc plan (·0.88 ±0.03) was higher than that in 5F-IMRT plan (0.79 ±0.02,t =8.28,P < 0.05).The homogeneity index (HI) in RapidArc plan 9.01 ± 0.73 was significantly lower than that in 5F-IMRT plan10.44 ± 1.08 (t =-2.73,P <0.05).For the dose volume delivered to the ipsilateral lung in two plans,the values of V10,V20,V30,and Dmean in RapidArc plan were lower than those in 5F-IMRT plan(t =-7.53,-7.20,-8.39,-7.80,P < 0.05).However,the value of V5 in RapidArc plan was higher than that in 5F-IMRT plan (t =5.67,P <0.05).For the heart,the values of V5,V10 and Dmean in RapidArc plan were higher than those in IMRT plan(t =10.46,28.76,5.40,P < 0.05),while the value of V30 in RapidArc plan was lower than that in 5F-IMRT plan(t =-6.12,P <0.05).The values of V5 in contralateral lung and breast were higher in RapidArc plan than those in 5F-IMRT plan(lung:t =21.50,P <0.05;breast:t =5.44,P <0.05).The MU in RapidArc plan was decreased by 25%,and the average treatment delivery time was saved by 60%,compared with that of 5F-IMRT plan.Conclusions During breast cancer radiotherapy after breast-conserving surgery,compared with 5F-IMRT plan,the RapidArc plan could improve the target HI,and reduce both the irradiated dose in high-dose volume and MU,and shorten the treatment time,but increased the exposed volume in low-dose volume of normal tissues.

SELECTION OF CITATIONS
SEARCH DETAIL