Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Traditional Patent Medicine ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-682042

ABSTRACT

Objective: To establish the method for determination of taurocholic acid in the Traditional Chinese Medicine Shedanchuanbei Oral Liquid and snake bile. Methods: The sample was prepared as mixed solution containing methanol and KH 2PO 4. The mixed solution was injected into Sep Pak C 18 cartridge for the purpose of sample purity. In this processing, the substances which having strong retain action and could harm analytic column were hold in the Sep Pak C 18 cartridge. The eluting solution that the Sep Pak C 18 cartridge had be over loading for taurocholic acid was used as the test solution. The test solution was measured by RP HPLC. The chromatographic conditions were as followed: Supelcosil LC 8 column(150mm?4.6nm,5?m) as analytic column, detect wavelength at 203nm, and MeOH 0.4%KH 2PO 4 mixed solution(56∶44, V/V ) as mobile phase. The inject volume was 50?L. Results: The linear response range of sodium taurocholate was from 0.0253mg?mL -1 to 0.253mg?mL -1 , and the correlation coefficient was 0.9999. The average recovery rate was 101.3%, RSD was 0.40%( n =6). Conclusion: This method was simple, efficient and suitable to the quality control for Shedanchuanbei Oral Liquid and snake bile.

2.
Chinese Traditional Patent Medicine ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-681102

ABSTRACT

Objective: To establish a method for the determination of metamizole sodium and chlorphenamine malete in zhongganling Tablets. Methods: The sample was determined by ion pair HPLC after it was purified on Sep Pak C 18 microcolumn. The chromatographic conditions included: Hypersil DBS C 18 chromatographic column (250mm?4.6mm, i.d.5?m) as an anlaytical column, methanol mixed solution of sodium heptanesulfonate and glacial acetic acid (600∶400) as a mobile phase, the detection wavelength at 264nm and 1.0mL?min -1 of flow rate. Results: The average recoveries of metamizole sodium and chlorphenamine maleate were 99.6% (RSD was 2.1% and n was 6) and 98.0% (RSD was 1.5% and n was 6), respectively. Conclusion: Metamizole sodium and chlorphenamine maleate can be determined respectively by HPLC with the same mobile phase when Sep Pak C 18 microcolumn solid phase extraction method is used to substitute for the traditional sample pretreatment methods refluxing, extracting and concentrating, and sodium heptanesulfonate ion pair reagent in acid condition is selected.

SELECTION OF CITATIONS
SEARCH DETAIL