Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add filters








Language
Year range
1.
Journal of Korean Medical Science ; : e11-2022.
Article in English | WPRIM | ID: wpr-915532

ABSTRACT

Background@#The purpose of this study was two-fold: 1) to identify differences in the characteristics of adopters and non-adopters of hearing aids (HAs); and 2) to investigate factors influencing the purchase of HA. @*Methods@#This study was conducted among 1,464 subjects (818 male and 646 female) with hearing loss. A national face-to-face survey was performed from August 2019 to October 2020 by otologists or HA experts. The questionnaire consisted of three domains:demographic, audiological, and HA-related domains. Multivariate logistic regression analysis was performed after adjusting for degree of hearing loss. @*Results@#The mean age of the participants was 70.4 ± 12.2 years. Of the 1,464 respondents, 1,190 (81.3%) had already purchased HA. We identified educational level, household income, hearing loss period, place of HA purchase, and government HA assistance program status as factors influencing HA adoption. Among these factors, third party reimbursement was the most important factor affecting HA purchase intent. The main reasons for not adopting HA were feeling that their hearing was adequate, inability to afford HA, and perceptions that HA are uncomfortable. @*Conclusion@#Various factors are involved in the purchase of HA, but disabled registration status and third party reimbursement were identified as the most critical factors. In the future, the government should take a more active role in increasing the distribution of HA to patients with hearing loss.

2.
Yonsei Medical Journal ; : 570-577, 2022.
Article in English | WPRIM | ID: wpr-927138

ABSTRACT

Purpose@#The purpose of this study is three-fold: 1) to evaluate factors influencing hearing aid (HA) satisfaction; 2) to provide a profile of HA satisfaction in daily life; and 3) to examine the reasons why people gave up using HAs. @*Materials and Methods@#Data for 1148 respondents were statistically analyzed and reported. @*Results@#In the study, age (β=-0.03, p<0.01), level of education (β=1.21, p<0.01), HA purchase price (β=1.50, p<0.01), bilateral amplification (β=1.23, p<0.01), wearing time (β=0.28, p<0.01), and HA fitting and fine tuning on a regular basis (β=1.71, p<0.01) significantly influenced HA satisfaction. In addition, the authors observed that the most satisfactory factors were clarity of sound (53.5%), people’s trust in their HA (61.7%), and listening from a quiet environment (72.8%) in the domains of sound quality, HA features, and listening environments, respectively. Finally, with multiple choices being possible, 65% of the 40 respondents who no longer used HAs answered that their HAs ended up in a drawer since the background noise was annoying and distracting. @*Conclusion@#This study is significant in that it is a large-scale multi-center research to comprehensively examine the factors influencing HA satisfaction in South Korea. This data will provide helpful information that could lead to the successful rehabilitation of hearing loss with HAs.

3.
Journal of Korean Medical Science ; : e94-2022.
Article in English | WPRIM | ID: wpr-925943

ABSTRACT

Background@#Hearing loss (HL) is the most common chronic disease and has been linked to negative health outcomes. Hearing aids (HAs) are regarded as the gold standard for HL management, however, the adoption rate of HAs is relatively low for various reasons. With this background, hearing devices, such as personal sound amplification products (PSAPs) received significant attention as an alternative to conventional HAs. This study aimed to evaluate the clinical efficacy of PSAPs in patients with mild to moderately severe HL. @*Methods@#Nineteen patients with mild hearing loss (MHL), 23 with moderate hearing loss (MDHL), and 15 with moderately severe hearing loss (MSHL) participated in the study.Electroacoustic analysis, simulated real-ear measurements (REMs), and three clinical evaluations were implemented. @*Results@#All devices satisfied the electroacoustic tolerances. All devices provided sufficient gain for MHL and MDHL audiograms. However, in MSHL audiogram, the gains of PSAPs were insufficient, especially for high frequencies. In terms of clinical evaluations, soundfield audiometry showed significant improvements between aided and unaided thresholds in all groups for all devices (P < 0.001). Significant improvements of word recognition scores were only shown for HAs between aided and unaided conditions. The Korean version of the Hearing In Noise Test did not show any consistent findings for all devices and groups. @*Conclusion@#Certain PSAPs are beneficial for improving hearing and speech perception in patients with HL. Well-chosen PSAPs could be an alternative hearing rehabilitation option for these patients.

4.
Journal of Korean Medical Science ; : e182-2022.
Article in English | WPRIM | ID: wpr-925920

ABSTRACT

Background@#The aim of this study is to investigate the clinical effectiveness of Ponto in Korea, a recently released percutaneous bone-anchored hearing implant. @*Methods@#16 patients with single-sided deafness (SSD) and mixed or conductive hearing loss who underwent Ponto implantation from December 2018 to September 2020 were enrolled in the study. Puretone audiometry, the Korean version of the Hearing in Noise Test (K-HINT), sound localization test (SLT), and Pupillometry were performed pre- and three months post-operation. Standardized questionnaires, the Hearing Handicap Inventory for the Elderly (HHIE) and Speech, Spatial and Qualities of Hearing Scale (SSQ), were administered. @*Results@#The mean age of subjects was 55.5 (range, 48–67) years. Four males and 12 females participated in the study. The mean puretone average was 73.17 dB hearing level (HL) before surgery and significantly improved to 36.72 dB HL three months after surgery. The mean word recognition score improved from 26.0% to 90.75% after implantation. In the case of K-HINT, there was a significant difference in summation (Z = −2.250, P = 0.024) and head shadow effects (Z = −3.103, P = 0.002). There was no significant difference in root mean square error degree (RMSE) and hemifield identification scores for SLT testing. Pupillometry was performed to measure listening effort and the results revealed that the degree of pupillary dilatation decreased under the condition of quiet, 0 dB signal to noise ratio (SNR) and 3 dB SNR. The total score for HHIE decreased significantly (Z = −3.130, P = 0.002) while the SSQ score increased significantly (Z = −2.216, P = 0.027). @*Conclusions@#The Ponto bone-anchored hearing system showed significant clinical benefit in Korean patients with conductive and mixed hearing loss and SSD.

5.
Clinical and Experimental Otorhinolaryngology ; : 127-134, 2022.
Article in English | WPRIM | ID: wpr-925729

ABSTRACT

The market for hearing technology is evolving—with the emergence of hearables, it now extends beyond hearing aids and includes any ear-level devices with wireless connectivity (i.e., wireless earbuds). However, will this evolving marketplace bring forth opportunities or challenges to individuals’ hearing health care and the profession of audiology and otolaryngology? The debate has been ongoing. This study explores the wide spectrum of hearables available in the market and discusses the necessity of high-quality clinical evidence prior to the implementation of over-the-counter devices into clinical practice.

6.
Clinical and Experimental Otorhinolaryngology ; : 60-68, 2022.
Article in English | WPRIM | ID: wpr-925721

ABSTRACT

Objectives@#. This study was conducted to investigate the electroacoustic characteristics of personal sound amplification products (PSAPs), to identify whether PSAPs provide adequate gain and output for three common hearing loss (HL) configurations, and to compare the benefits of a representative PSAP (RPSAP) and a conventional hearing aid (HA) for clinical hearing outcomes as a pilot study. @*Methods@#. The study comprised three phases: electroacoustic analysis, simulated real-ear measurements (REMs), and clinical hearing experiments. Electroacoustic analysis and simulated REMs were performed for three basic PSAPs (BeethoSOL, EarJJang, and Geniesori2) and three high-end PSAPs (Hearing Able, Olive Smart Ear, and SoriIn) using the Aurical Hearing Instrument Test box with a 2-mL coupler. Four electroacoustic characteristics (maximum output sound pressure level at 90 dB SPL, frequency range, equivalent input noise, and total harmonic distortion) were investigated. By simulated REMs, appropriate levels of the six PSAPs for three common HL configurations (mild-to-moderate high-frequency HL, moderate to moderately severe sloping HL, and moderate flat HL) were determined. Clinical experiments compared the performance of RPSAP to HA, both of which were fitted by audiologists using REMs. Clinical experiments were administered using functional gain, a word recognition test, and the Korean version of the Hearing in Noise Test in six participants with bilateral moderate sensorineural HL. @*Results@#. The two high-end devices met all tolerances. One basic and two high-end PSAPs showed appropriate levels for three common HL configurations. In the clinical experiments, the RPSAP showed better performance than unaided, but slightly worse than HA under all test conditions. @*Conclusion@#. Certain PSAPs met all specified tolerances for electroacoustic analysis and approximated prescriptive targets in well-controlled laboratory conditions. The pilot clinical experiments explored the possibility that the RPSAP could serve as a hearing assistive device for patients with moderate HL.

7.
Clinical and Experimental Otorhinolaryngology ; : 185-191, 2021.
Article in English | WPRIM | ID: wpr-889891

ABSTRACT

Objectives@#. The aim of this study was to investigate the current university admission rate and experiences of educational support among students with cochlear implants (CIs) in South Korea. @*Methods@#. A prospective online survey was conducted to examine the university admission process and academic support for students with CIs. Thirty individuals who took the college entrance exams at least 3 years after CI surgery were invited to participate, although two did not respond. The survey consisted of three topics (demographics, university admission process, and academic support) and 25 items regarding laws and policies related to university admission and support for students with hearing disabilities in Korea. @*Results@#. The university matriculation rate for students with CI was 85.7% (24/28), of whom 50% were admitted through the special admission process for students with disabilities. Most universities provided teaching and learning support and rental services for assistive devices for students with disabilities to help them better adapt to school life. However, only a small percentage of the students benefited from accommodation services, and 62.5% and 12.5% of the students received teaching and learning support and used assistive devices, respectively. @*Conclusion@#. To the best of our knowledge, this is the first study to investigate the university admission process and university disability services for students with CIs in South Korea. The results of this study will be helpful for young CI recipients and their parents as they prepare for university entrance.

8.
Clinical and Experimental Otorhinolaryngology ; : 185-191, 2021.
Article in English | WPRIM | ID: wpr-897595

ABSTRACT

Objectives@#. The aim of this study was to investigate the current university admission rate and experiences of educational support among students with cochlear implants (CIs) in South Korea. @*Methods@#. A prospective online survey was conducted to examine the university admission process and academic support for students with CIs. Thirty individuals who took the college entrance exams at least 3 years after CI surgery were invited to participate, although two did not respond. The survey consisted of three topics (demographics, university admission process, and academic support) and 25 items regarding laws and policies related to university admission and support for students with hearing disabilities in Korea. @*Results@#. The university matriculation rate for students with CI was 85.7% (24/28), of whom 50% were admitted through the special admission process for students with disabilities. Most universities provided teaching and learning support and rental services for assistive devices for students with disabilities to help them better adapt to school life. However, only a small percentage of the students benefited from accommodation services, and 62.5% and 12.5% of the students received teaching and learning support and used assistive devices, respectively. @*Conclusion@#. To the best of our knowledge, this is the first study to investigate the university admission process and university disability services for students with CIs in South Korea. The results of this study will be helpful for young CI recipients and their parents as they prepare for university entrance.

9.
Journal of Audiology & Otology ; : 145-152, 2019.
Article | WPRIM | ID: wpr-764218

ABSTRACT

BACKGROUND AND OBJECTIVES: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. SUBJECTS AND METHODS: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. RESULTS: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. CONCLUSIONS: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.


Subject(s)
Action Potentials , Cochlear Implants , Ear , Electrodes , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL