Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Korean Journal of Nephrology ; : 158-161, 2010.
Article in English | WPRIM | ID: wpr-179473

ABSTRACT

This is the first case of glyphosate induced severe tubulointerstitial nephritis requiring hemodialysis without cardiovascular collapse. A 67-year-old man presented to the hospital 30 minutes after ingesting 90 mL of glyphosate herbicide. On arrival, his serum creatinine was 0.8 mg/dL and other laboratory findings including liver, cardiac, and muscle enzymes were all normal. Two days after admission, although his vital signs were stable, his creatinine abruptly increased to 8.2 mg/dL and oliguria developed. As a result, we started hemodialysis treatment and two weeks after initiation of hemodialysis, his renal function started to improve slowly. After discontinuation of hemodialysis, his renal function gradually recovered and serum creatinine level decreased to 1.6 mg/dL three weeks after admission.


Subject(s)
Aged , Humans , Creatinine , Glycine , Liver , Muscles , Nephritis, Interstitial , Oliguria , Renal Dialysis , Vital Signs
2.
Korean Journal of Physical Anthropology ; : 63-68, 1994.
Article in Korean | WPRIM | ID: wpr-124006

ABSTRACT

The odontoid process of the ninety axis were measured to observe the morphological features in Koreans. The results are as follows. 1. Height of the ordontoid of process of axis was 14.1±1.3mm, and the degree of the height of the odontoid process to the height of axis was frequency of 38.2±2.6%. 2. Transverse diameter of odontoid process of the most axis (87.8%) was thinner at the lower part than at the upper part. And the difference of the thickness of upper part and lower part was 1.2±0.7mm. In anteroposterior diameter, lower part was thinner than upper part in frequency of 55.6%, and the difference of upper part and lower part was 1.0±0.5mm in the transverse diameter, 0.6±0.5mm in the anteroposterior diameter, therefore the thickness of the anteroposterior diameter. 3. The articular surface of the odontoid process of the axis articulating with the anterior arch of atlas was 8.9±1.7mm in the maximal length and 7.1±1.6mm in the maximal breadth.


Subject(s)
Odontoid Process
3.
Korean Journal of Physical Anthropology ; : 21-26, 1991.
Article in Korean | WPRIM | ID: wpr-224624

ABSTRACT

No abstract available.


Subject(s)
Adult , Humans , Ophthalmic Artery
SELECTION OF CITATIONS
SEARCH DETAIL