Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Genomics & Informatics ; : e12-2023.
Article in English | WPRIM | ID: wpr-976792

ABSTRACT

A wave of new technologies has created opportunities for the cost-effective generation of high-throughput profiles of biological systems, foreshadowing a "data-driven science" era. The large variety of data available from biological research is also a rich resource that can be used for innovative endeavors. However, we are facing considerable challenges in big data deposition, integration, and translation due to the complexity of biological data and its production at unprecedented exponential rates. To address these problems, in 2020, the Korean government officially announced a national strategy to collect and manage the biological data produced through national R&D fund allocations and provide the collected data to researchers. To this end, the Korea Bioinformation Center (KOBIC) developed a new biological data repository, the Korea BioData Station (K-BDS), for sharing data from individual researchers and research programs to create a data-driven biological study environment. The K-BDS is dedicated to providing free open access to a suite of featured data resources in support of worldwide activities in both academia and industry.

2.
Korean Journal of Anesthesiology ; : 61-70, 2022.
Article in English | WPRIM | ID: wpr-926565

ABSTRACT

Background@#Although the association between an increase in anastomotic leakage (AL) and non-steroidal anti-inflammatory drugs (NSAIDs) has been reported in gastrointestinal surgeries, this issue has rarely been addressed for pancreaticoduodenectomy (PD). We aimed to investigate the association between postoperative NSAIDs administration and clinically relevant AL (CR-AL) following PD. @*Methods@#We retrospectively evaluated 2,163 consecutive patients who underwent PD between 2007 and 2019. The patients were divided into two groups; patients who received and did not receive NSAIDs by postoperative day (POD) 5. We conducted a propensity score analysis using inverse probability of treatment weighting (IPTW) to adjust the baseline differences between both groups. We compared the occurrence of CR-AL and other postoperative outcomes before and after IPTW. Further, we used the multivariable binary logistic regression method for a sensitivity analysis for CR-AL. @*Results@#A total of 2,136 patients were included in the analysis. Of these, 222 (10.4%) received NSAIDs by POD 5. The overall occurrence rate of CR-AL was 14.9%. After IPTW, postoperative NSAIDs were significantly associated with CR-AL (odds ratio [OR]: 1.24, 95% CI [1.05, 1.47], P = 0.012), prolonged postoperative hospitalization (OR: 1.31, 95% CI [1.14, 1.50], P < 0.001), and unplanned readmission within 30 days postoperatively (OR 1.48: 95% CI [1.15, 1.91], P = 0.002). However, this association was not consistent in the sensitivity analysis. @*Conclusions@#Postoperative NSAIDs use was significantly associated with an increase in CR-AL incidence following PD. However, sensitivity analysis failed to show its association, which precludes a firm conclusion of its detrimental effect.

3.
Korean Journal of Blood Transfusion ; : 131-140, 2020.
Article | WPRIM | ID: wpr-836491

ABSTRACT

Background@#An increasing number of blood banks use an automated analyzer in ABO blood typing to reduce the high workload and impact of human error. On the other hand, the automated system often causes ABO discrepancies, where cell and serum typing do not match. Hence, the manual method is used for confirmation.This study evaluated the appropriateness of retesting with the manual method. In addition, the causes of ABO discrepancies were analyzed. @*Methods@#A total of 77,590 blood samples were tested with the AutoVue Innova for ABO typing. Among them, 1280 samples were retested manually due to ABO discrepancies. The causes of the discrepancies were analyzed further through additional tests. The serum reaction grades in both methods were compared. @*Results@#ABO typing of 76,906 samples (99.12%), which included 596 manually confirmed samples could be confirmed by the AutoVue system, while 403 samples (0.52%) continued to yield discrepant results. Weak serum reactions in the AutoVue system were observed, as previously reported. One hundred and thirty samples (66.7%), which were graded 0.5+ in the automated analyzer, yielded a negative serum reaction in the manual method, showing a greater serum reaction with the AutoVue system than with the manual method. @*Conclusion@#The AutoVue Innova performs reliably for blood typing. On the other hand, the manual method is still useful as retesting to address the ABO discrepancies and weak or strong serum reactions. In particular, it is important to confirm samples with 0.5+ grade serum reactions manually.

4.
Korean Journal of Blood Transfusion ; : 262-272, 2018.
Article in Korean | WPRIM | ID: wpr-718919

ABSTRACT

BACKGROUND: Massive hemorrhage due to trauma is one of the major causes of death in trauma patients, and the quick supply of appropriate blood products is critical in order to reduce the mortality rate. We introduced a massive transfusion protocol (MTP) for safe and rapid transfusion of trauma patients. Using records collected since its adoption, we compared the characteristics of MTP applied group (MTP group) and MTP not applied group (non-MTP group) to determine whether there is an indicator for predicting patients to be treated with MTP. METHODS: We retrospectively reviewed the electronic medical records and laboratory findings of patients who received massive transfusions in the trauma emergency room of a single tertiary hospital from February to August 2018. We analyzed various laboratory test results, the amount and ratio of the transfused blood products, and the time required for blood products to be released for the MTP group and the non-MTP group. RESULTS: Of the 54 trauma patients who received massive transfusions, 31 were in the MTP group and 22 in the non-MTP group. There was no significant difference in initial vital signs (except blood pressure) and laboratory test results. Also there was no difference in the amount and ratio of blood products, but the time required for blood product release was shorter in the MTP group. CONCLUSION: There was no significant difference in clinical findings such as initial vital signs and laboratory test results between the MTP and non-MTP groups, but required blood products were prepared and released more quickly for the MTP group.


Subject(s)
Humans , Cause of Death , Electronic Health Records , Emergency Service, Hospital , Hemorrhage , Mortality , Retrospective Studies , Tertiary Care Centers , Vital Signs
SELECTION OF CITATIONS
SEARCH DETAIL