Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of the Korean Geriatrics Society ; : 176-180, 2015.
Article in Korean | WPRIM | ID: wpr-88235

ABSTRACT

Quetiapine is an atypical antipsychotic that is frequently used to manage delirium in geriatric patients. Acute pancreatitis associated with quetiapine has rarely been reported. A 70-year-old male presented with severe abdominal pain a few hours after taking a dose of quetiapine prescribed for delirium. Despite the lack of risk factors of pancreatitis in his medical history, the patient had a slight increase of serum lipase and amylase levels. His general condition improved on discontinuation of quetiapine. A month later, quetiapine was readministered for the recurrence of delirium. Subsequently, the patient developed the same symptom with a significant increase in serum pancreatic enzyme levels, confirming that quetiapine induced the pancreatitis. We reported the first case of quetiapine-induced pancreatitis in Korea, together with a review of the literature.


Subject(s)
Aged , Humans , Male , Abdominal Pain , Amylases , Delirium , Korea , Lipase , Pancreatitis , Recurrence , Risk Factors , Quetiapine Fumarate
2.
Journal of Korean Academy of Conservative Dentistry ; : 457-466, 2003.
Article in Korean | WPRIM | ID: wpr-69241

ABSTRACT

OBJECTIVES: The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. METHODS: Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow - were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bonded' free shrinkage method at varying C-factor in the range of 1~8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. RESULTS: In non-bonded method, the linear shrinkage approximated one third of true volumetric shrinkage by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5~6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.


Subject(s)
Anisotropy , Compensation and Redress , Composite Resins , Polymerization , Polymers , Viscosity
SELECTION OF CITATIONS
SEARCH DETAIL