Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Journal of Cerebrovascular and Endovascular Neurosurgery ; : 341-348, 2022.
Article in English | WPRIM | ID: wpr-967081

ABSTRACT

Background@#Anterior choroidal artery (AchA) aneurysms are usually small in diameter because of the size of the involved artery and are often wide-necked. Coil embolization of AchA aneurysm is thus challenging because of serious risks, such as thromboembolic occlusion of artery and perforation of aneurysm dome. Therefore, aneurysmal neck clipping remains widely performed despite a recent increase in the use of coil embolization for aneurysm treatment. We report the treatment results of AchA aneurysms mostly (92.3%) treated with coil embolization at our institute. @*Methods@#The database and medical records of patients who underwent coil embolization for AchA aneurysms were retrospectively analyzed. The clinical and imaging results and procedure-related complications were investigated after coil embolization performed between January 2006 and March 2022 at our institute. @*Results@#In total, 96 AchA aneurysms comprising 65 unruptured and 31 ruptured aneurysms, including only 1 ruptured aneurysm (1.0%) re-embolized at postoperative day 192 because of coil compaction, were evaluated. After the initial coil embolization, complete occlusion was attained in 41, residual neck in 45, and residual aneurysm in 10 patients. Follow-up radiological studies after 6–174 months were performed for 80 aneurysms. Complete occlusion was noted in 57 patients, residual neck in 22, and residual aneurysm in 1. The dysarthria experienced by one (1.0%) patient was the only symptomatic procedure-related complication. After coil embolization, neither delayed new rupture nor re-rupture was observed. @*Conclusions@#The results of this study demonstrate that coil embolization is a safe and effective treatment option for patients with AchA aneurysms.

2.
The Journal of Advanced Prosthodontics ; : 395-405, 2014.
Article in English | WPRIM | ID: wpr-53231

ABSTRACT

PURPOSE: This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS: A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computer-guided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (alpha=.05). RESULTS: The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION: In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery.


Subject(s)
Humans , Dental Clinics , Dental Implants , Dentists , Hospitals, University , Patient Satisfaction
4.
The Journal of Korean Academy of Prosthodontics ; : 753-759, 2007.
Article in English | WPRIM | ID: wpr-45794

ABSTRACT

STATEMENT OF PROBLEM: In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading specially. PURPOSE: The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs under unilateral loading, using strain gauge analysis. MATERIAL AND METHODS: Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1: Clasp-retained mandibular removable partial denture with unsplinted abutments Group 2: Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3: Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two unilateral vertical experimental loadings (30N and 100N) were applied subsequently via miniature load cell that were placed at mandibular left first molar region. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Tukey test was used as post hoc comparisons. RESULTS: The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Strain values increased as the applied load increased from 30N to 100N (P<.05) except for right side in group 1. Under 30N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (P<.05). And group 2 showed higher strain values than group 1 (P<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (P<.05). Under 100N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (P<.05). And group 2 showed higher strain values than group 1 (P<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (P<.05). Under 30N loading, group 2 and 3 showed higher strain values in right side than in left side. Under 100N loading, right side strain values were higher than left side ones for all groups. CONCLUSION: Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments under unilateral loading. Bar-retained removable partial denture showed the lowest strain of three groups, and compressive nature.


Subject(s)
Denture, Partial, Removable , Molar , Splints , Tooth , Tooth, Artificial
5.
The Journal of Korean Academy of Prosthodontics ; : 745-750, 2005.
Article in English | WPRIM | ID: wpr-65854

ABSTRACT

STATEMENT OF PROBLEM: Resonance frequency analysis has been increasingly served as a noninvasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. PURPOSE: This study was performed to evaluate RFA value changes in two anodized implant groups. MATERIAL AND METHOD: Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were Branemark Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using Osstell(TM) (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. RESULTS: Mean and SD of baseline ISQ values of test group were 75.0 +/- 3.4 and 68.7 +/- 8.1 for control group. Mean and SD of ISQ values 12 weeks after implant insertion were 73.2 +/- 4.7 for test group and 72.6 +/- 3.9 for control group. There were no statistically significant differences between groups in ISQ values after 3months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). CONCLUSION: Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.


Subject(s)
Seoul , Tibia , Titanium
6.
The Journal of Korean Academy of Prosthodontics ; : 699-713, 2003.
Article in English | WPRIM | ID: wpr-176012

ABSTRACT

Statement of problem. Titanium is the most important material for biomedical and dental implants because of their high corrosion resistance and good biocompatibility. These beneficial properties are due to a protective passive oxide film that spontaneously forms on the surface. Purpose. The purpose of this study was to evaluate the responses of osteoblast-like cells on different surface treatments on Ti discs. Material and Methods. Group 1 represented the machined surface with no treatment. Group 2 surfaces were sandblasted with 50microm Al2O3 under 5 kgf/cm2 of pressure. Groups 3 and 4 were sandblasted under the same conditions. The samples were treated on a titanium oxide surface with reactive sputter depositioning and thermal oxidation at 600degree C (Group 3) and 800degree C (Group 4) for one hour in an oxygen environment. The chemical composition and microtopography were analyzed by XRD, XPS, SEM and optical interferometer. The stability of TiO2 layer was studied by potentiodynamic curve. To evaluate cell response, osteoblast extracted from femoral bone marrow of young adult rat were cultured for cell attachment, proliferation and morphology on each titanium discs. Results and Conclusion. The results were as follows : 1.Surface roughness values were, from the lowest to the highest, machined group, 800degree C thermal oxidation group, 600degree C thermal oxidation group and blasted group. The Ra value of blasted group was significantly higher than that of 800degree C thermal oxidation group (P=0.003), which was not different from that of 600degree C thermal oxidation group (P0.05). 3. The level of cell proliferation showed no difference among the groups after one day, three days, and seven days (P>0.05). 4. The morphology and arrangement of the cells varied with surface roughness of the discs.


Subject(s)
Animals , Humans , Rats , Young Adult , Bone Marrow , Cell Proliferation , Corrosion , Dental Implants , Osteoblasts , Oxygen , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL