Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Language
Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 264-271, 2017.
Article in English | WPRIM | ID: wpr-90428

ABSTRACT

PURPOSE: The purpose of this study is to investigate the differences in bond strength of four different indirect composites to the gold alloy and Ni-Cr alloy according to type of metal surface treatment after water storage. MATERIALS AND METHODS: Type IV gold alloy and Ni-Cr alloy were used for casting alloy while four types of indirect composite resins (Gradia, Tescera Sinfony and in;joy) were used in this study. Metal specimens were produced by casting and total of 240 specimens (60 specimens per one indirect composite group) were prepared. After bonding indirect composite resin and undergoing 24 hours of polymerization, customized jig was attached to the metal specimen and shear bond strength were measured using universal testing machine. Also, differences in shear bond strength before and after water storage for 240 hours were also measured. RESULTS: In the measurement of shear bond strength according to the metal surface treatments, bead group showed high strength followed by loop and flatting group (P<.05). After being stored in water bath for 240 hours, Gradia showed statistically significant high bond strength compared to other indirect composite resins in all groups (P<.05). CONCLUSION: Shearbond strength was found to be different according to type of metal surface treatment and type of metal used after storage in water. Further studies need to be developed for clinical practices as three are still problems of microleakage, stain or wear.


Subject(s)
Alloys , Baths , Composite Resins , Polymerization , Polymers , Water
2.
The Journal of Advanced Prosthodontics ; : 465-471, 2016.
Article in English | WPRIM | ID: wpr-213528

ABSTRACT

PURPOSE: The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS: Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 10⁶ cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS: Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION: Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.


Subject(s)
Crowns , Fungi , Mastication , Prostheses and Implants , Torque
3.
The Journal of Advanced Prosthodontics ; : 494-501, 2013.
Article in English | WPRIM | ID: wpr-227893

ABSTRACT

PURPOSE: The purpose of this study was to provide an actual guideline in determining the shape, diameter, and position of the implant in immediate implantation by the measurement of the thickness of facial and palatal plate, the thickness of cortical bone on the facial and palatal plate, the diameter of the root, and the distance between the roots in the cadavers. MATERIALS AND METHODS: The horizontal sections of 20 maxillae were measured and analyzed to obtain the average values. Resin blocks were produced and cut serially at 1 mm intervals from the cervical line to the root apex. Images of each section were obtained and the following measurements were performed: The thickness of the facial and palatal residual bone at each root surface, the thickness of the facial and palatal cortical bone at the interdental region, the diameter of all roots of each section on the faciopalatal and mesiodistal diameter, and the interroot distance. Three specimens with measurements close to the average values were chosen and 3-dimensional images were reconstructed. RESULTS: The thickness of the facial and palatal cortical bone at the interdental region in the maxilla, the buccal cortical bone was thicker in the posterior region compared to the anterior region. The interroot distance of the alveolar bone thickness between the roots increased from anterior to posterior region and from coronal to apical in the maxilla. CONCLUSION: In this study, the limited results of the morphometric analysis of the alveolar ridge using the sections of maxilla in the cadavers may offer the useful information when planning and selecting optimal implant for immediate implantation in the maxilla.


Subject(s)
Alveolar Process , Cadaver , Maxilla
4.
The Journal of Advanced Prosthodontics ; : 374-381, 2013.
Article in English | WPRIM | ID: wpr-159883

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the effect of alendronates on bone remodeling around titanium implant in the maxilla of rats. MATERIALS AND METHODS: The maxillary first molars were extracted and customized-titanium implants were placed immediately in thirty male Sprague-Dawley rats. The rats were divided into experimental (bisphosphonate) group and control group. At 4 weeks after implantation, the rats in the bisphosphonate group were subcutaneously injected with alendronate three times a week for 6 weeks where as the rats in control group were injected with saline. The rats were sacrificed at 1, 2, 3, 4, or 6 weeks after starting of injection and maxillary bones were collected subsequently. Alveolar bone remodeling around the implants were evaluated by radiographic and histologic analysis. Microarray analysis and immunohistomorphologic analysis were also performed on one rat, sacrificed at 6 weeks after starting of injection, from each group. Statistical analysis was performed using repeated measures analysis of variance and independent t test at a significance level of 5%. RESULTS: There was no statistically significant difference in the bone area (%) around implant between the bisphosphonate group and the control group. However, the amount of empty lacuna was significantly increased in the bisphosphonate group, especially in the rats sacrificed at 4 weeks after starting of injection compared to that of the corresponding control group. The bisphosphonate group showed the same level of TRAP positive cell count, osteocalcin and angiopoietin 1 as the control group. CONCLUSION: Alendronate may not decrease the amount of osteoclast. However, the significantly increased amount of empty lacuna in the bisphosphonate group may explain the suppression of bone remodeling in the bisphosphonate group.


Subject(s)
Animals , Humans , Male , Rats , Alendronate , Angiopoietin-1 , Bisphosphonate-Associated Osteonecrosis of the Jaw , Bone Remodeling , Cell Count , Jaw , Maxilla , Microarray Analysis , Molar , Osteocalcin , Osteoclasts , Rats, Sprague-Dawley , Titanium
5.
Journal of Periodontal & Implant Science ; : 166-172, 2012.
Article in English | WPRIM | ID: wpr-21443

ABSTRACT

PURPOSE: The aim of this study was to evaluate the improvement of osteogenic potential of biphasic calcium phosphate (BCP) bone substitute coated with synthetic cell-binding peptide sequences in a standardized rabbit sinus model. METHODS: Standardized 6-mm diameter defects were created bilaterally on the maxillary sinus of ten male New Zealand white rabbits, receiving BCP bone substitute coated with synthetic cell binding peptide sequences on one side (experimental group) and BCP bone substitute without coating (control group) on the other side. Histologic and histomorphometric analysis of bone formation was carried out after a healing period of 4 or 8 weeks. RESULTS: Histological analysis revealed signs of new bone formation in both experimental groups (4- and 8-week healing groups) with a statistically significant increase in bone formation in the 4-week healing group compared to the control group. However, no statistically significant difference in bone formation was found between the 8-week healing group and the control group. CONCLUSIONS: This study found that BCP bone substitute coated with synthetic cell-binding peptide sequences enhanced osteoinductive potential in a standardized rabbit sinus model and its effectiveness was greater in the 4-week healing group than in the 8-week healing group.


Subject(s)
Humans , Male , Rabbits , Artificial Cells , Bone Regeneration , Bone Substitutes , Calcium , Durapatite , Hydroxyapatites , Maxillary Sinus , Oligopeptides , Osteogenesis
6.
Journal of Periodontal & Implant Science ; : 119-126, 2012.
Article in English | WPRIM | ID: wpr-11335

ABSTRACT

PURPOSE: The aim of this study was to determine whether biphasic calcium phosphate (BCP) bone substitute with two different concentrations of Escherichia coli-expressed recombinant human bone morphogenetic protein 2 (ErhBMP-2) enhances new bone formation in a standardized rabbit sinus model and to evaluate the concentration-dependent effect of ErhBMP-2. METHODS: Standardized, 6-mm diameter defects were made bilaterally on the maxillary sinus of 20 male New Zealand white rabbits. Following removal of the circular bony windows and reflection of the sinus membrane, BCP bone substitute without coating (control group) was applied into one defect and BCP bone substitute coated with ErhBMP-2 (experimental group) was applied into the other defect for each rabbit. The experimental group was divided into 2 subgroups according to the concentration of ErhBMP-2 (0.05 and 0.5 mg/mL). The animals were allowed to heal for either 4 or 8 weeks and sections of the augmented sinus and surrounding bone were analyzed by microcomputed tomography and histologically. RESULTS: Histologic analysis revealed signs of new bone formation in both the control and experimental groups with a statistically significant increase in bone formation in experimental group 1 (0.05 mg/mL ErhBMP-2 coating) after a 4-week healing period. However, no statistically significant difference was found between experimental group 1 and experimental group 2 (0.5 mg/mL ErhBMP-2 coating) in osteoinductive potential (P<0.05). CONCLUSIONS: ErhBMP-2 administered using a BCP matrix significantly enhanced osteoinductive potential in a standardized rabbit sinus model. A concentration-dependent response was not found in the present study.


Subject(s)
Animals , Humans , Male , Rabbits , Bone Morphogenetic Protein 2 , Bone Morphogenetic Proteins , Bone Regeneration , Bone Substitutes , Calcium , Durapatite , Escherichia coli , Hydroxyapatites , Maxillary Sinus , Membranes , Osteogenesis , X-Ray Microtomography
7.
Korean Circulation Journal ; : 339-342, 2010.
Article in English | WPRIM | ID: wpr-196627

ABSTRACT

LEOPARD syndrome (LS) is a rare hereditary disorder in Asian countries. This syndrome consists of multiple systemic abnormalities. In particular, characteristic cardiovascular effects in LS may include variable clinical manifestations from benign to life-threatening courses. The cardiac effects of this syndrome consist of left ventricular hypertrophy (LVH), pulmonary stenosis (PS), coronary artery dilatation and electrocardiogram(ECG) abnormalities. Since there are few LS patients who have undergone a complete cardiovascular evaluation, the nature and clinical prognosis of cardiovascular abnormalities in this syndrome remain uncertain. Also, there have been few reports on therapeutic strategies for cardiovascular abnormalities in LS. Here we describe a case of LS who presented with multiple cardiovascular problems and underwent successful surgical and medical treatment.


Subject(s)
Humans , Asian People , Cardiovascular Abnormalities , Coronary Vessels , Dilatation , Hypertrophy, Left Ventricular , Lentigo , LEOPARD Syndrome , Panthera , Prognosis , Pulmonary Valve Stenosis
8.
Japanese Journal of Physical Fitness and Sports Medicine ; : 143-154, 2009.
Article in English | WPRIM | ID: wpr-362498

ABSTRACT

PURPOSE : To determine the patterns of electromyographic (EMG) responses and torques of upper extremity muscles in overhead throwers during maximal, eccentric muscle action for shoulder flexion (Flex<sub>Ecc</sub>), abduction (Abd<sub>Ecc</sub>) and diagonal activities (Dia<sub>Ecc</sub>) with full glenohumeral internal rotation, at 60, 120, and 180°/s on the dynamometer.METHODS : Seven asymptomatic subjects (7 men, 4 women) who participate in overhead sports at least three days a week volunteered to participate in this study. Subjects were randomly performed with the test procedure which consisted of at least 5 grade maximal-effort repetitions on the three different testing conditions, at 60, 120, and 180°/s on the dynamometer, while we assessed muscle activation of the anterior deltoid (AD), middle deltoid (MD), posterior deltoid (PD), upper trapezius (UT), middle trapezius (MT), lower trapezius (LT), and biceps brachii (BB) muscles by surface electromyography. EMG data was expressed as a percentage of maximum voluntary isometric contraction (%MVIC) that was obtained from the highest root mean square (RMS, 50 ms) of each muscle and was normalized and averaged.RESULT : AD muscle elicited lower muscle activity during Dia<sub>Ecc</sub> than Flex<sub>Ecc</sub> and Abd<sub>Ecc</sub> (P<0.05) while the MD, PD, UT, MT, and LT muscles elicited overall greater muscle activities during Dia<sub>Ecc</sub>. MD and MT muscle activities were significantly greater for the faster speed than for the slower speed as 60°/s during Abd<sub>Ecc</sub> (P<0.05). Peak torque generated greater muscle strength for Dia<sub>Ecc</sub> than Flex<sub>Ecc</sub> and Abd<sub>Ecc</sub>, and it was significantly greater for the faster speed than slower speed during Dia<sub>Ecc</sub> (P<0.05).CONCLUSION : Posterior upper extremity muscle activities and peak torque values were found to be dependent on eccentric muscle action for diagonal shoulder activity at the faster speed. This study provided evidence that isokinetic eccentric muscle strength testing of the posterior upper extremity muscle was effective to develop of a proper program for overhead sports athletes require forceful stability during deceleration phase.

SELECTION OF CITATIONS
SEARCH DETAIL