Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. odontol. UNESP (Online) ; 46(6): 319-324, Nov.-Dec. 2017. tab, ilus
Article in English | LILACS, BBO | ID: biblio-902684

ABSTRACT

Objective: To evaluate and correlate the values of radiographic bone density, peri-implant bone height and resonance frequency analysis (RFA) of short or conventional implants placed in the posterior region of the mandible after installing a prosthesis. Material and method: Eleven patients were selected for this prospective parallel pilot study. The prostheses were supported by two types of implants: short implants (n = 18) (5.0 x 5.5 mm and 5.0 x 7.0 mm) and conventional implants (n = 23) (4.0 x10 mm and 4.0 x 11.5 mm). The implants were evaluated by RFA, by measuring the bone height, and peri-implant bone density. The implants were evaluated at the periods T0 (immediately after installation of the prosthesis), T1 (after 90 days), and T2 (after 180 days). Result: There were no statistically significant differences between groups with respect to radiographic bone density (152.50 ± 15.39 vs. 157.60 ± 28.46, for conventional and short implants, respectively at T2), stability of the implants (Conventional implants: 66.76 ± 10.39 at T0, and 61.85 ± 8.38 at T2 vs. Short implants: 57.50 ± 12.17 at T0, and 61.53 ± 7.39 at T2) and peri-implant bone loss (0.03 mm vs.-0.17 mm, for conventional and short implants, respectively at T2). Additionally, a significant correlation between the evaluated parameters was not detected. Conclusion: The short and conventional implants presented similar stability, bone level and density after the activation of occlusion loading.


Objetivo: Avaliar e correlacionar os valores de densidade óssea radiográfica, altura óssea peri-implantar e de frequência de ressonância nos implantes curtos e convencionais instalados na região posterior da mandíbula após a instalação da prótese provisória. Material e método: Esse estudo piloto clínico prospectivo contou com a participação de 11 pacientes que foram divididos previamente em dois grupos: implantes curtos (n=18) (5,0 x 5,5 mm e 5,0 x 7,0 mm) e implantes convencionais (n=23) (4,0 x 10 mm e 4,0 x 11,5 mm). Foram executadas análise da frequência de ressonância, altura óssea e densidade óssea peri-implantar. Os implantes foram avaliados nos períodos T0 (imediatamente após a instalação do provisório), T1 (após 90 dias) e T2 (após 180 dias). Resultado: Não houve diferenças estatisticamente significativas entre os grupos com relação a densidade óssea radiográfica (152,50 ± 15,39 vs. 157,60 ± 28,46, para implantes convencionais e curtos respectivamente no período T2), estabilidade dos implantes (Implantes convencionais: 66,76 ± 10,39 no período T0 e 61,85 ± 8,38 no período T2 vs. Implantes curtos: 57,50 ± 12,17 no período T0 e 61,53 ± 7,39 no período T2) e quanto a perda óssea periimplantar (0,03 mm vs. -0,17 mm, em implantes convencionais e curtos no período T2, respectivamente). Adicionalmente a isso, não foram detectados correlação significativa entre densidade radiográfica com altura óssea peri-implantar e nem com a frequência de ressonância. Conclusão: Verificou-se que os implantes curtos apresentaram um comportamento semelhante aos implantes de comprimento convencionais com relação à frequência de ressonância, a densidade radiográfica peri-implantar e a manutenção dos níveis ósseos periimplantares.


Subject(s)
Humans , Prostheses and Implants , Bone Resorption , Bone Density , Dental Implants , Denture, Partial, Temporary , Mandible
2.
Braz. dent. j ; 18(2): 102-106, 2007. ilus, tab
Article in English | LILACS | ID: lil-466500

ABSTRACT

The purpose of this study was to investigate the influence of cervical preflaring on determination of the initial apical file in maxillary lateral incisors. Forty human lateral incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL (WL) was set 1 mm short of the apical foramen. Four groups (n=10) were formed at random, according to the type of cervical preflaring performed. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle root canal thirds. Group 2 had the cervical and middle root canal thirds enlarged with nickel-titanium Orifice Opener instruments. Group 3 had the cervical and middle root canal thirds enlarged with Gates-Glidden drills. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle root canal thirds of group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were recorded (in mm) for each sample. Significant differences were found between the groups regarding the anatomical diameter at the WL and the first file to bind the canal (p = 0.01). The major discrepancy was found when no preflaring was performed (0.1882 mm average). Canals preflared with Orifice Opener instruments (0.0485 mm average) and Gates-Glidden drills (0.1074 mm average) also showed great discrepancy. The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.0119 mm average). Instrument binding technique for determining anatomical diameter...


Avaliou-se a influência do pré-alargamento cervical na determinação do instrumento apical inicial em incisivos laterais superiores. Foram selecionados quarenta incisivos laterais superiores com completa formação radicular. Concluída cirurgia de acesso, uma lima tipo K #06 foi inserida em cada canal até atingir o forame apical. A partir desse comprimento foi reduzido 1 mm e determinou-se o comprimento de trabalho. Os dentes foram divididos em cinco grupos (n=10), de acordo com o tipo de alargamento cervical realizado: Grupo 1: sem alargamento; Grupo 2: instrumentos Orifice Opener; Grupo 3: brocas Gates-Glidden; Grupo 4: LA Axxess. Os canais foram explorados com lima do tipo K inserindo-se passivamente a lima 08 no comprimento de trabalho. A seguir, limas de maiores diâmetros foram sucessivamente introduzidas no canal radicular, até se obter a sensação de travamento no comprimento de trabalho. O diâmetro desse instrumento foi registrado, e este foi fixado em posição no canal com cianoacrilato de metila. Secções transversais realizadas no comprimento de trabalho foram observadas em lupa estereoscópica com auxílio de máquina fotográfica acoplada e as imagens foram digitalizadas. A diferença entre o menor diâmetro do canal e o diâmetro do instrumento apical inicial foi calculada para cada amostra (em mm). A análise estatística indicou diferença estatisticamente significante entre os grupos experimentais (p=0.01). A maior discrepância foi representada pelo grupo que não recebeu o pré-alargamento (média: 0,1882 mm). O grupo no qual o pré-alargamento foi realizado com instrumentos Orifice Opener também apresentou elevada discrepância entre o diâmetro anatômico e o instrumento apical inicial (média: 0,0485 mm), seguido pelo grupo que se utilizou Gates-Glidden (média: 0,1074 mm). As brocas LA Axxess promoveram a menor diferença entre o diâmetro anatômico no comprimento de trabalho e o instrumento apical inicial (média: 0,0119 mm). Pode-se concluir...


Subject(s)
Humans , Dental Pulp Cavity/pathology , Incisor/pathology , Root Canal Preparation/instrumentation , Tooth Apex/pathology , Dental Alloys , Equipment Design , Image Processing, Computer-Assisted , Maxilla , Nickel , Root Canal Preparation/methods , Stainless Steel , Surface Properties , Titanium , Tooth Cervix
SELECTION OF CITATIONS
SEARCH DETAIL