Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. Col. Bras. Cir ; 44(6): 603-611, Nov.-Dec. 2017. graf
Article in English | LILACS | ID: biblio-896636

ABSTRACT

ABSTRACT Objective : to determine the functional and morphological effects at rabbits retina of PS80 concentration used in the preparation of intravitreal drugs. Methods: eleven New Zealand rabbits received a intravitreal injection of 0.1ml of PS80. As control, the contralateral eye of each rabbit received the same volume of saline. Electroretinography was performed according to a modified protocol, as well as biomicroscopy and retina mapping before injection and seven and ten days after. Animals were euthanized in the 30th day and the retinas were analyzed by light microscopy. Results: eyes injected with PS80 did not present clinical signs of intraocular inflammation. Electroretinography did not show any alteration of extent and implicit time of a and b waves at scotopic and photopic conditions. There were no morphological alterations of retinas at light microscopy. Conclusion: intravitreal injection of PS80 in the used concentration for intravitreal drug preparations do not cause any functional or morphological alterations of rabbit retinas. These results suggest that PS80 is not toxic to rabbit retinas and may be safely used in the preparation of new lipophilic drugs for intravitreal injection.


RESUMO Objetivo: determinar os efeitos funcionais e morfológicos na retina de coelhos da concentração de PS80 utilizada na preparação de drogas intravítreas. Métodos: onze coelhos New Zealand receberam injeção intravítrea de 0,1ml de PS80. Como controle, o olho contralateral de cada coelho recebeu o mesmo volume de soro fisiológico. Foram realizados eletrorretinogramas de acordo com o protocolo modificado, biomicroscopia e mapeamento de retina antes da injeção, sete e dez dias depois. Os animais foram sacrificados no 30o dia e as retinas analisadas por microscopia de luz. Resultados: os olhos injetados com PS80 não apresentaram sinais clínicos de inflamação intraocular. O eletrorretinograma não apresentou alteração de amplitude e tempo implícito das ondas a e b nas condições escotópica e fotópica. Não houve alteração morfológica da retina na microscopia de luz. Conclusão: a injeção intravítrea de PS80 na concentração utilizada na preparação de drogas intravítreas não causa alterações funcionais e morfológicas na retina de coelhos. Esses resultados sugerem que o PS80 não é tóxico para a retina de coelhos e pode ser usado com segurança na preparação de novas drogas lipofílicas para injeção intravítrea.


Subject(s)
Animals , Polysorbates/administration & dosage , Retina/anatomy & histology , Retina/physiology , Rabbits , Retina/drug effects , Electroretinography , Intravitreal Injections
2.
Rev. bras. oftalmol ; 73(3): 135-137, May-Jun/2014. graf
Article in English | LILACS | ID: lil-727179

ABSTRACT

Purpose: Register and compare anatomical changes, structural and quantitative found in optical coherence tomography Stratus and Topcon 3D in chronic users of chloroquine. Methods: Five patients were diagnosed with toxic "bull's eye" maculopathy was submitted to macular optical coherence tomography examination (Stratus and Topcon 3D). Results: Both tools demonstrated an increase reflectivity of choriocapillaris unit just foveal retinal pigment epithelium atrophy. However, Topcon 3D provided to all patients better description of the line corresponding to the transition between inner and outer segments of photoreceptors. Using the possibility of assembling threedimensional images and subtraction selective retinal layers, we found a lesion with a target that reflects the greater thickness of retinal pigment epithelium in central and parafoveal region that is matched to preserve macular photoreceptors. Conclusion: it was observed better resolution and faster image capture by Topcon 3D than Stratus OCT, that provided more detailed analysis of the line corresponding to transition between outer and inner segment of photoreceptors in macular region. With Topcon 3D, it was possible to evaluate soundly the thickness of retinal pigment epithelium in central and parafoveal region that caused an increase reflectivity of choriocapillaris creating a image with a target unpublished before. .


Objetivo: Comparar e registrar as alterações quantitativas e qualitavivas na tomografia de coerência óptica nos pacientes com uso prolongado de cloroquina. Métodos: Avaliaram-se cinco pacientes com diagnóstico de bull’s eye no exame de tomografia de coerência óptica macular com dois modelos de aparelhos: Stratus e Topcon 3D. Resultados: Ambos aparelhos registraram aumento da refletividade coriocapilar foveal provocada pela atrofia do epitélio pigmentar da retina. Somente o Topcon 3D permitiu melhor visibilização da linha de transição entre o segmento interno e externo dos fotorreceptores. Este aparelho também permitiu a formação de imagens tridimensionais e subtração das camadas retinianas, com registro da diminuição da espessura do epitélio pigmentado da retina na região central e parafoveal macular. Conclusão: Foi possível observar a captação mais rápida e com melhor resolução das imagens geradas pelo Topcon 3D. A diminuição da espessura do epitélio pigmentado da retina, provocando o aumento da refletividade coriocapilar, com a formação de uma imagem linear circular cincundando a fóvea, foi mais detalhado pelos cortes realizados no Topcon 3D. .


Subject(s)
Humans , Retinal Diseases/chemically induced , Retinal Diseases/diagnostic imaging , Chloroquine/adverse effects , Tomography, Optical Coherence/methods , Macular Degeneration/chemically induced , Macular Degeneration/diagnostic imaging , Retina/drug effects , Retina/pathology , Retina/diagnostic imaging , Chloroquine/administration & dosage
3.
Arq. bras. oftalmol ; 73(4): 377-378, July-Aug. 2010. ilus
Article in Portuguese | LILACS | ID: lil-560616

ABSTRACT

A síndrome de Brown enquadra-se no grupo de estrabismos restritivos e é causada pela limitação de movimento do tendão do oblíquo superior através da tróclea. Caracteriza-se por ortotropia ou hipotropia na primária do olhar, limitação ou ausência de elevação em adução, frequente depressão do olho em adução com anisotropia em V e dução passiva positiva na elevação em adução. Denomina-se síndrome de Brown inflamatória, o distúrbio secundário, que tem como principais causas inflamações locais na órbita e doenças inflamatórias como artrite reumatóide e tenossinovite. Apresentamos o caso de um paciente de 44 anos, do sexo masculino, com queixa de diplopia binocular vertical à dextroversão recorrente. Diagnosticado como síndrome de Brown inflamatória sem etiologia definida, confirmada por ressonância nuclear magnética e com resolução espontânea.


Brown syndrome fits the group of restrictive strabismus and is caused by a movement limitation of the superior oblique tendon through the trochlea. It is characterized by parallelism in the primary gaze position, limitation or absence of elevation in adduction, frequent depression of the eye in adduction with anisotropy in V-pattern and positive passive duction in the elevation in adduction. It is called inflammatory Brown syndrome, a secondary disorder, which main causes are local inflammation in the orbit and inflammatory diseases such as rheumatoid arthritis and tenosynovitis. A case of a 44 year-old patient, male, complaining of binocular vertical diplopia due to recurring dextroversion is reported. It was diagnosed as inflammatory Brown syndrome of uncertain etiology, confirmed by magnetic nuclear resonance, and with spontaneous resolution.


Subject(s)
Adult , Humans , Male , Ocular Motility Disorders/diagnosis , Strabismus/diagnosis , Eye Movements , Oculomotor Muscles/physiopathology , Syndrome
4.
Rev. bras. oftalmol ; 67(5): 214-219, set.-out. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-497324

ABSTRACT

OBJETIVO: Avaliar a condição ocular em população de trabalhadores de uma indústria metalúrgica paulista. MÉTODOS: Amostra de 2516 funcionários de uma fábrica na cidade de São Paulo foi submetida a uma avaliação oftalmológica como exame ocupacional periódico. Foi aplicado um questionário e realizado o exame de acuidade visual (Snellen) e teste de Ishihara. Os funcionários com acuidade visual menor que 0,7 ou com diferenças maior que duas linhas ou que apresentassem alguma queixa ocular, passaram por avaliação complementar (biomicroscopia, refração, tonometria e fundo de olho). Prescreveu-se óculos conforme indicação. RESULTADOS: Houve predomínio do sexo masculino (62,5 por cento) e faixa etária de 20 a 29 anos (41 por cento). A maioria não apresentava antecedentes oculares (97,6 por cento) ou sistêmicos (96,6 por cento).A acuidade visual estava acima de 0,7 em 95,5 por cento dos olhos e 84 por cento não utilizavam correção. O diagnóstico final foi exame normal em 55 por cento dos casos, presbiopia em 13.6 por cento, astigmatismo miópico em 10 por cento e hipermetrópico em 7,7 por cento dos indivíduos. Baixa visão foi encontrada em 2,4 por cento, cegueira unilateral em 0,4 por cento, não havendo casos de cegueira ou de deficiência visual entre os trabalhadores. As principais causas de baixa visão foram erros refrativos e ambliopia. CONCLUSÃO: A maioria dos funcionários da indústria pesquisada apresentava exame oftalmológico normal e nenhum deles apresentava cegueira bilateral.


PURPOSE: To evaluate the ocular condition in a brazilian ironmaster industry. METHOD: A prospective study was conducted in 2516 employees from an ironmaster brazilian industry in São Paulo city, Brazil. A questionnaire was applied and visual acuity and Ishihara test were performed in every individual. A complete ophthalmic evaluation (slit lamp examination, fundoscopy, tonometry and refractometry) was done when the visual acuity was worse than 0.7 or when the worker had a greater diference between the eyes (more than two lines) or when there were ocular complains. Glasses were prescribed when necessary. RESULTS: Most of the evaluated employees in this industry was male (62.5 percent), ageing from 20 to 29 year old (41 percent). Visual acuity was normal in 95.5 percent of the eyes.The majority of the individuals (84 percent) did not need glasses prescription. Fifty-five percent of the employees were considered as normal eye carriers, 13.6 percent presented presbyopia, 10 percent presented myopic astigmatism and 7.7 percent hyperopic astigmatism. Visual impairment was present in 2,4 percent and blindness in one eye of 0,4 percent of the studied individuals. The main cause of visual impairment was refractive errors and amblyopia. CONCLUSION: The majority of the employees, in this particular industry, presented with a normal ophthalmic examination. None of them had bilateral blindness.

5.
Arq. bras. oftalmol ; 69(1): 23-26, jan.-fev. 2006. tab
Article in Portuguese | LILACS | ID: lil-420812

ABSTRACT

OBJETIVO: Conhecer as características dos portadores de blefarospasmo essencial e espasmo hemifacial, assim como a resposta ao tratamento utilizando toxina botulínica A. MÉTODOS: Trinta e quatro portadores de blefarospasmo essencial ou espasmo hemifacial foram avaliados quanto a idade, sexo, queixas oculares, tempo de existência da doenca, tipo de comprometimento, complicacões e resultado do tratamento com toxina botulínica A. RESULTADOS: A mediana da idade dos pacientes foi de 63 anos e a média, de 61 anos, sem diferenca quanto ao sexo; 66,66 por cento possuíam espasmo hemifacial e 33,33 por cento, blefarospasmo essencial. Vários pacientes apresentavam também olho seco. A melhora com a utilizacão da toxina botulínica A ocorreu em 91,30 por cento dos pacientes tratados. As complicacões com o tratamento foram ptose palpebral (8,33 por cento) e desvio da rima bucal (8,33 por cento). CONCLUSAO: O blefarospasmo essencial e o espasmo hemifacial geralmente acometem idosos, de ambos os sexos. O tratamento com a toxina botulínica A é eficiente, com índice muito baixo de complicacões.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Blepharospasm/drug therapy , Botulinum Toxins, Type A/therapeutic use , Hemifacial Spasm/drug therapy , Neuromuscular Agents/therapeutic use , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL