Korean Journal of Anesthesiology ; : 227-233, 1985.
Article in Korean | WPRIM | ID: wpr-164493

ABSTRACT

During general anesthesia, removal of exhaled carbon dioxide by rebreathing appliances is provided by chemical absorption and this carbon dioxide absorption during anesthesia would at first glance seem to be a simple problem. The problem, however, is far more complicated and much attention must be given to details of rebreathing appliances. Incomplete removal of carbon dioxide in circle absorber systems, which are commonly used today must be carefully monitored to prevent hypercapnea caused by accumulation of carbon dioxide in the breathing circuits. Although circle absorbers have been developed through clinical trials anesthesiologists have no reliable indication of the end point of useful life of the absorbent. This study was undertaken to investigate the useful life of the soda lime used in two type of canisters (type A: canister of anesthesia machine. Quantiflex, USA. 12.9cmX16.6cm, tbye B: canister of anesthesia machine, International 2. U.K., 13.1cmX16.9cm). the effect of flow rate on this useful life and the relations between indicator change and the endpoint of useful life of the soda lime. The control group used a as total flow rate of fresh gases at 2.0 liters per minute and the experimental group used a total flow rate of 4.0 liters per minute. The carbon dioxide concentration of 0.1% at the canister exit was employed as the end point of useful life of the absorbent and the exit carbon dioxide concentration were monitored continuously by intra-red carbon dioxide monitor apparatus(Datex Normocap CD-102, Pinland). Also the carbon dioxide concentration in the respiratory circuit of exhaling side was examined. The results were as follows: 1) In type A, the average useful life of soda lime was 1,885 minutes in the control group and 2,514 minutes in the experimental group. In type B, the average useful life of soda lime was 1,587 minutes in the control group and 1,980 minutes in the experimental group. 2) At the end point of useful life of the absorbent the level of the color change of the indicator of the absorbent in all types was above the three-fourth height of two chambered canister. 3) At the end point, end tidal CO2 concentration was 3.5 vol% in the control group 2.88 vol% in the experimental group. The data obtained from this observation indicated that the increase of total flow rate of gas and the type A canister prolonged the useful life of soda lime and that the double chambered canister could be used safely until the color change of the indicator reached the level of three fourth the height of the canister.


Subject(s)
Absorption , Anesthesia , Anesthesia, General , Carbon Dioxide , Exhalation , Gases , Respiration
2.
Korean Journal of Anesthesiology ; : 178-182, 1983.
Article in Korean | WPRIM | ID: wpr-157739

ABSTRACT

Anestheiologists are called upon to undertake, or to assist in the management of severe respiratory and circulatory emergencies that may occur in myasthenics or to administer anesthesia for thymectomy or other surgical procedures to be performed on myasthenic subjects. Consequently the well-trained anesthesiologists must be sufficinetly familiar with the diagnosis and treatment of myasthenia gravis to carry on the therapy. A case of anesthesia for thymectomy in myasthenia gravis was experience. During operation, 0.1% succinylcholine in dripp method was given for adequate muscle relaxation and no respiratory probelms were encountered postoperatively.


Subject(s)
Anesthesia , Diagnosis , Emergencies , Muscle Relaxation , Myasthenia Gravis , Succinylcholine , Thymectomy
3.
Korean Journal of Anesthesiology ; : 199-204, 1979.
Article in Korean | WPRIM | ID: wpr-174657

ABSTRACT

Cardiac electromechanical dissociation is a cause of cardiac arrest and this is characterized by regularly recurring QRS complexes and T waves- P waves may even be present. without an obtainable blood pressure and pulse. Such findings in man are almost invariably associated with a fatal outcome although one can observe this phenomenon in potentially treatable disorders. Recognition of these disorders on the basis of certain clinical and electrocardiographic findings may be of clinical importance. This experimental study on rabbits was performed to observe electromechanical dissociation (E.M.D.) and to recognize its clinical importance, in exsanguinating hemorrhage with the cutting of the right femoral artery. The results were as follows: 1) The incidence of E.M.D. was 100 percent. 2) In the all cases except two cardiac rhythm showed sinus rhythm but in two cases it was difficult to distinguish it from nodal rhythm. 3) Heart rate at the time of E.M.D showed a significant increase of 13,8 percent as compared with the control. 4) The voltage of the P wave and QRS complex at the time of E.M.D. showed a significant decreases of the former, 34.7%, and the latter, 30%, as compared with the control. and the QRS complex at the time of E.M.D showed severe axis deviation. 5) In seven cases in all, the voltage of the T wave at the time of E.M.D, showed a significant decrease of 61. 3 percent (one case showed T wave inversion) and the others showed. conversely a significant increase of 271 percent. 6) Regarding change of interval, the QRS interval showed no changes and P-R and Q-T intervals showed shortening of 14, 7% and 2.4%. 7) We consider that devices for heart sound, pulse or blood pressure monitoring should be: combined with ECG monitoring.


Subject(s)
Rabbits , Blood Pressure , Blood Pressure Monitors , Electrocardiography , Exsanguination , Fatal Outcome , Femoral Artery , Heart Arrest , Heart Rate , Heart Sounds , Incidence