1.
Journal of the Korean Ophthalmological Society ; : 20-24, 2016.
Article in Korean | WPRIM | ID: wpr-59408

ABSTRACT

PURPOSE: To evaluate the objective amplitude of accommodation in various age groups using an autorefractometer and to compare the results with subjective assessments on accommodation. Objective accommodative amplitude of artificial lenses in post-operative cataract patients was also measured. METHODS: In this study, 41 patients who visited Korea University Guro Hospital from July through August 2014 were categorized into 6 different age groups. Accommodative amplitude was measured using long-distance refraction at 5 m and short-distance refraction at 20 cm. In 20 patients, subjective amplitude of accommodation was measured using the minus lens technique and was compared with the measured objective accommodative amplitude. Accommodative amplitude was also measured in 8 patients who received cataract surgery. RESULTS: The mean accommodative ability in normal people was 2.38 D. The age groups of 10-19, 20-29, 30-39, 40-49, 50-59, and over 60 years showed accommodative amplitudes of 3.31 +/- 0.99 D, 3.25 +/- 0.34 D, 3.78 +/- 0.68 D, 1.00 +/- 0.60 D, 0.22 +/- 0.23 D, 0.00 +/- 0.00 D, respectively. The results showed a rapid decrease in accommodative ability of patients older than 40 years and demonstrated a correlation between objective and subjective amplitude of accommodation (Pearson's correlation coefficient 0.838). There was a significant difference between objective and subjective accommodative amplitudes in artificial lenses (p = 0.015), with average objective and subjective measures of 0.10 +/- 0.23 D and 0.59 +/- 0.35 D, respectively. CONCLUSIONS: Measuring amplitude of accommodation using an autorefractometer can be useful in assessing results of presbyopia treatment.


Subject(s)
Humans , Cataract , Korea , Presbyopia
2.
Journal of the Korean Ophthalmological Society ; : 876-880, 2016.
Article in Korean | WPRIM | ID: wpr-136321

ABSTRACT

PURPOSE: Warm compression using a commercial heat pad was used to evaluate the effects of temperature on the eyelids and tear film lipid layer thickness. METHODS: Targeting 13 patients (26 eyes) with non-specific eye disease such as dry eye syndrome or Meibomian gland dysfunction, we measured the average thickness of the tear film lipid layer in both eyes with the LipiView 2® System (Tearscience®, Morrisville, NY, USA). We performed warm compression on the right eye only in order to evaluate the effectiveness of massage and measured the temperature of the right eye lid immediately, 3 minutes, and 5 minutes after compression in order to compare with the untreated left eye. After warm compression for 5 minutes, we measured tear film lipid layer thickness of both eyes and analyzed the effectiveness of warm compression. RESULTS: The average tear film lipid layer thickness was 55.1 ± 21.0 nm in the right eyes and 53.9 ± 13.9 nm in the left eyes (p = 0.474). Before performing the warm compression, the temperature of the right eye lid was 53.9 ± 13.9 nm, and that of the left was 35.9 ± 0.2℃. The eye lid temperature of the right eye immediately, 3 minutes, and 5 minutes after warm compression was 40.3 ± 1.3℃, 40.3 ± 1.3℃, and 40.3 ± 1.9℃, respectively, and these temperatures were relatively constant during the massage. Tear film lipid layer thickness after warm compression in the right eye was 83.5 ± 18.8 nm, which was increased compared to the original temperature (p = 0.001) and showed significant difference compared with the 65.5 ± 27.1 nm in the left eye (p = 0.005). CONCLUSIONS: Warm compression increased the tear film lipid layer thickness and showed a relatively constant increased temperature of 40.3℃ over 5 minutes. This technique will be helpful for maintaining tear film lipid layer thickness in patients with Meibomian gland dysfunction.


Subject(s)
Humans , Dry Eye Syndromes , Eye Diseases , Eyelids , Hot Temperature , Massage , Meibomian Glands , Tears
3.
Journal of the Korean Ophthalmological Society ; : 876-880, 2016.
Article in Korean | WPRIM | ID: wpr-136320

ABSTRACT

PURPOSE: Warm compression using a commercial heat pad was used to evaluate the effects of temperature on the eyelids and tear film lipid layer thickness. METHODS: Targeting 13 patients (26 eyes) with non-specific eye disease such as dry eye syndrome or Meibomian gland dysfunction, we measured the average thickness of the tear film lipid layer in both eyes with the LipiView 2® System (Tearscience®, Morrisville, NY, USA). We performed warm compression on the right eye only in order to evaluate the effectiveness of massage and measured the temperature of the right eye lid immediately, 3 minutes, and 5 minutes after compression in order to compare with the untreated left eye. After warm compression for 5 minutes, we measured tear film lipid layer thickness of both eyes and analyzed the effectiveness of warm compression. RESULTS: The average tear film lipid layer thickness was 55.1 ± 21.0 nm in the right eyes and 53.9 ± 13.9 nm in the left eyes (p = 0.474). Before performing the warm compression, the temperature of the right eye lid was 53.9 ± 13.9 nm, and that of the left was 35.9 ± 0.2℃. The eye lid temperature of the right eye immediately, 3 minutes, and 5 minutes after warm compression was 40.3 ± 1.3℃, 40.3 ± 1.3℃, and 40.3 ± 1.9℃, respectively, and these temperatures were relatively constant during the massage. Tear film lipid layer thickness after warm compression in the right eye was 83.5 ± 18.8 nm, which was increased compared to the original temperature (p = 0.001) and showed significant difference compared with the 65.5 ± 27.1 nm in the left eye (p = 0.005). CONCLUSIONS: Warm compression increased the tear film lipid layer thickness and showed a relatively constant increased temperature of 40.3℃ over 5 minutes. This technique will be helpful for maintaining tear film lipid layer thickness in patients with Meibomian gland dysfunction.


Subject(s)
Humans , Dry Eye Syndromes , Eye Diseases , Eyelids , Hot Temperature , Massage , Meibomian Glands , Tears
4.
Journal of the Korean Ophthalmological Society ; : 195-199, 2016.
Article in Korean | WPRIM | ID: wpr-77153

ABSTRACT

PURPOSE: To analyze the improvement of symptoms and signs of dry eye after surgical punctual occlusion and to evaluate the effects of secondary systemic disease in dry eye patients. METHODS: From March 2011 to July 2014, 15 eyes of 8 dry eye patients with a history of punctal plug insertion underwent surgical punctal occlusion. Schirmer test was measured based on mean 2.9 mm. The patients consisted of 4 dry eye patients with Sjogren's disease, 1 with rheumatoid arthritis, 1 with graft-versus-host disease (GVHD), and 2 with no secondary systemic disease. Preoperative and postoperative ophthalmic examinations of log MAR visual acuity, subjective symptoms, corneal staining (National Eye Institute [NEI] score), and tear break-up time (BUT) were performed and the effects of secondary systemic disease in dry eye patients were evaluated. The results of surgical punctual occlusion were analyzed. RESULTS: All patients showed a statistically significant improvement of log MAR visual acuity, subjective symptoms, corneal staining (NEI score), and tear BUT. The patients with rheumatoid-related diseases showed improved symptoms after surgery, but the patient with GVHD showed no significant improvement after surgery. Among the study patients, 80.0% showed completely closed punctum and 20.0% showed partial recanalization. CONCLUSIONS: Surgical punctal occlusion is an effective alternative in patients with severe aqueous deficient dry eye who show recurrent punctal plug loss or complications associated with punctal plugs.


Subject(s)
Humans , Arthritis, Rheumatoid , Graft vs Host Disease , Sjogren's Syndrome , Tears , Visual Acuity
5.
Journal of the Korean Ophthalmological Society ; : 784-788, 2015.
Article in Korean | WPRIM | ID: wpr-226682

ABSTRACT

PURPOSE: To report a case of decreased endothelial cell density 7 years after posterior chamber phakic intraocular lens implantation. CASE SUMMARY: A 45-year-old man with high myopia combined with astigmatism was treated with Toric implantable Collamer Lens (ICL) implantation. The patient's best corrected visual acuity was 0.7 in both eyes before the operation. After the treatment, his uncorrected visual acuity was 0.9 and corrected visual acuity was 1.0 in both eyes, indicating an improvement in visual function. Preoperative endothelial cell density measured 3,063 cells/mm2 in the right eye and 3,126 cells/mm2 in the left eye. At 5 years postoperatively, measurements were 2,897 cells/mm2 in the right eye and 2,974 cells/mm2 in the left, showing little change. However, a 6-year postoperative measurement of 2,198 cells/mm2 in the right eye and 2,803 cells/mm2 in the left showed a slight decrease in endothelial cell density in the right eye, and a follow-up measurement one year later displayed a rapid decline to 1,272 cells/mm2 in the right eye and 2,852 cells/mm2 in the left eye. The Toric ICL lens was removed from the right eye and phacoemulsification and posterior chamber intraocular lens implantation was performed. Two-month postoperative endothelial cell density was 1,257 cells/mm2 and endothelial cell damage from the operation itself was minimal. CONCLUSIONS: ICL implantation may cause complications related to corneal endothelial cells as well as glaucoma. Patients should receive regular follow-up examinations for endothelial cell density.


Subject(s)
Humans , Middle Aged , Astigmatism , Endothelial Cells , Follow-Up Studies , Glaucoma , Lens Implantation, Intraocular , Lenses, Intraocular , Myopia , Phacoemulsification , Phakic Intraocular Lenses , Visual Acuity
6.
Journal of the Korean Ophthalmological Society ; : 532-540, 2015.
Article in Korean | WPRIM | ID: wpr-203440

ABSTRACT

PURPOSE: The present study investigates the patterns of internal optical aberrations in eyes with different types of cataract. METHODS: Eighty eyes of 70 cataract patients were included in the present study. Internal optical aberrations were measured with a KR-1W wavefront aberrometer before cataract operation. Types of cataract were classified into three groups; cortical, nuclear and posterior subcapsular cataracts. The differences in the results of the wavefront data of 6-mm pupil diameter zones were compared among three groups. The Kruskal-Wallis test and Mann-Whitney U test were used for comparing data. RESULTS: A total of 80 eyes consisting of 30 cortical cataracts, 30 nuclear cataracts and 20 posterior subcapsular cataracts were found. In the 6-mm pupil diameter zone, the average internal spherical aberrations by original value were 0.042 microm of cortical cataracts, -0.092 microm of nuclear cataracts and -0.109 microm of posterior subcapsular cataracts. The average internal spherical aberrations by absolute value were 0.122 microm of cortical cataracts, 0.533 microm of nuclear cataracts and 0.202 microm of posterior subcapsular cataracts. The internal spherical aberrations by original value were not statistically significantly different, but by absolute value were statistically significantly different (p = 0.003, Kruskal-Wallis test). Nuclear cataracts have a much higher positive or negative value than other cataract groups in the distribution of internal spherical aberrations by original value for each type of cataract. Other than this difference, the internal astigmatism and internal high order aberrations were not statistically significantly different. CONCLUSIONS: The change in internal spherical aberrations of nuclear cataract from the original value was larger than cortical and posterior subcapsular cataract. Therefore, nuclear cataracts have much higher positive or negative values than other cataract groups.


Subject(s)
Humans , Astigmatism , Cataract , Pupil
7.
Journal of the Korean Ophthalmological Society ; : 1613-1617, 2014.
Article in Korean | WPRIM | ID: wpr-41569

ABSTRACT

PURPOSE: To assess the changes in mean corneal refractive power (DeltaK) following pterygium surgery and to predict DeltaK in cases of combined cataract and pterygium surgery. METHODS: Thirty-seven eyes of unilateral pterygium patients who underwent pterygium surgery were analyzed retrospectively with at least more than 1 month of follow-up. Preoperative and postoperative 1 month corneal refractive power was measured using auto-keratometer (RK-F1, Canon, Tokyo, Japan). Pterygium horizontal extension, width, and area were measured and correlation with DeltaK before and after surgery analyzed. We also compared DeltaK of the contralateral normal eye. RESULTS: The mean corneal refractive (Km) power measured before and 1 month after surgery was 43.30 +/- 1.66 D and 44.07 +/- 1.42 D, respectively. The Km significantly increased at 4 weeks after surgery (p < 0.001). However, postoperative Km was not significantly different when compared with the contralateral normal eye (43.86 +/- 1.34 D; p = 0.59). All parameters of pterygium size including horizontal extension, width, and area were positively correlated with the mean DeltaK. Among parameters, horizontal extension was best correlated with mean DeltaK (p < 0.001). The mean DeltaK with horizontal extension was predicted using linear regression (2.5 mm to 1 D, 4.0 mm to 1.8 D). CONCLUSIONS: We recommend contralateral corneal refractive power or prediction of corneal refractive power using linear regression with pterygium horizontal extension for determining intraocular lens power in cases of combined cataract and pterygium surgery.


Subject(s)
Humans , Cataract , Follow-Up Studies , Lenses, Intraocular , Linear Models , Pterygium , Retrospective Studies
8.
Korean Journal of Ophthalmology ; : 53-56, 2010.
Article in English | WPRIM | ID: wpr-22605

ABSTRACT

A case of acquired Brown syndrome caused by surgical repair of medial orbital wall fracture is reported in the present paper. A 23-year-old man presented at the hospital with right periorbital trauma. Although the patient did not complain of any diplopia, the imaging study revealed a blow-out fracture of the medial orbital wall. Surgical repair with a calvarial bone autograft was performed at the department of plastic surgery. The patient was referred to the ophthalmologic department due to diplopia that newly developed after surgery. The prism cover test at distant fixation showed hypotropia of the right eye, which was 4 prism diopters (PD) in primary gaze, 20 PD in left gaze, while orthophoric in right gaze. Eye movement of the right eye was markedly limited on elevation in adduction with normal elevation in abduction with intorsion in the right eye present. Forced duction test of the right eye showed restricted elevation in adduction. Computerized tomography scan of the orbits showed the right superior oblique muscle was entrapped between the autografted bone fragment and posterior margin of the fracture. When repairing medial orbital wall fracture that causes Brown syndrome, surgeons should always be careful of entrapment of the superior oblique muscle if the implant is inserted without identifying the superior and posterior margin of the orbital fracture site.


Subject(s)
Humans , Male , Young Adult , Bone Transplantation/adverse effects , Diplopia/etiology , Ocular Motility Disorders/etiology , Ophthalmologic Surgical Procedures/adverse effects , Orbital Fractures/surgery , Tomography, X-Ray Computed , Transplantation, Autologous
9.
Journal of the Korean Ophthalmological Society ; : 1795-1799, 2009.
Article in Korean | WPRIM | ID: wpr-96515

ABSTRACT

PURPOSE: To establish the accuracy of the newly released biometer Ocuscan RxP(R) (Alcon, USA) by comparison with the established Ultrasonic Biometer Model 820(R) (Allergan Humphrey, USA), and to compare the accuracy of contact and immersion biometries. METHODS: This is a prospective study involving 27 patients (40 eyes) who were scheduled for cataract surgery and had axial lengths measured with an Ocuscan RxP(R) biometer using both contact (Method 1) and immersion (Method 2) techniques. As a reference, a contact type Ultrasonic biometer 820(R) (Method 3) was also used. IOL(Intraocular Lens) power for the cataract surgery was calculated using this result. An axial length which would have caused no post-operative refractive error was reversely calculated from the difference of target diopter and post-operative refractive error. This length was compared with the axial lengths obtained via Methods 1, 2 and 3. RESULTS: The means and standard deviations for the measurement sets were compared. Methods 1 and 2 showed no significant difference (23.22+/-0.68, 23.24+/-0.69 mm, p=0.55). The axial length measured by Method 3 was 23.32+/-0.67 mm. The difference between the target refraction and post-operative refractive error was 0.29+/-0.60D. The axial length was reversely calculated from the difference (23.07+/-0.84 mm). The differences between the reversely calculated axial lengths and those of Methods 1, 2 and 3 were 0.15+/-0.31, 0.17+/-0.31 and 0.24+/-0.28 mm, respectively. CONCLUSIONS: Biometric results from Methods 1 and 2 caused less refractive error than did Method 3. The contact and immersion methods are both accurate for IOL power calculation if performed by a well-skilled examiner.


Subject(s)
Humans , Biometry , Cataract , Cimetidine , Immersion , Prospective Studies , Refractive Errors , Ultrasonics