Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Ann Card Anaesth ; 2016 Oct; 19(4): 599-605
Article in English | IMSEAR | ID: sea-180917

ABSTRACT

Background: Traditional two‑dimensional (2D) echocardiographic evaluation of tricuspid annulus (TA) dilation is based on single‑frame measurements of the septolateral (S‑L) dimension. This may not represent either the axis or the extent of dynamism through the entire cardiac cycle. In this study, we used real‑time 3D transesophageal echocardiography (TEE) to analyze geometric changes in multiple axes of the TA throughout the cardiac cycle in patients without right ventricular abnormalities. Materials and Methods: R‑wave‑gated 3D TEE images of the TA were acquired in 39 patients undergoing cardiovascular surgery. The patients with abnormal right ventricular/tricuspid structure or function were excluded from the study. For each patient, eight points along the TA were traced in the 3D dataset and used to reconstruct the TA at four stages of the cardiac cycle (end‑ and mid‑systole, end‑ and mid‑diastole). Statistical analyses were applied to determine whether TA area, perimeter, axes, and planarity changed significantly over each stage of the cardiac cycle. Results: TA area (P = 0.012) and perimeter (P = 0.024) both changed significantly over the cardiac cycle. Of all the axes, only the posterolateral‑anteroseptal demonstrated significant dynamism (P < 0.001). There was also a significant displacement in the vertical axis between the points and the regression plane in end‑systole (P < 0.001), mid‑diastole (P = 0.014), and mid‑systole (P < 0.001). Conclusions: The TA demonstrates selective dynamism over the cardiac cycle, and its axis of maximal dynamism is different from the axis (S‑L) that is routinely measured with 2D TEE.

2.
Ann Card Anaesth ; 2016 Jan; 19(1): 15-19
Article in English | IMSEAR | ID: sea-172254

ABSTRACT

Objectives: Contrary to the rest of the mitral annulus, inter‑trigonal distance is known to be relatively less dynamic during the cardiac cycle. Therefore, intertrigonal distance is considered a suitable benchmark for annuloplasty ring sizing during mitral valve (MV) surgery. The entire mitral annulus dilates and flattens in patients with ischemic mitral regurgitation (IMR). It is assumed that the fibrous trigone of the heart and the intertrigonal distance does not dilate. In this study, we sought to demonstrate the changes in mitral annular geometry in patients with IMR and specifically analyze the changes in intertrigonal distance during the cardiac cycle. Methods: Intraoperative three‑dimensional transesophageal echocardiographic data obtained from 26 patients with normal MVs undergoing nonvalvular cardiac surgery and 36 patients with IMR undergoing valve repair were dynamically analyzed using Philips Qlab® software. Results: Overall, regurgitant valves were larger in area and less dynamic than normal valves. Both normal and regurgitant groups displayed a significant change in annular area (AA) during the cardiac cycle (P < 0.01 and P < 0.05, respectively). Anteroposterior and anterolateral‑posteromedial diameters and inter‑trigonal distance increased through systole (P < 0.05 for all) in accordance with the AAs in both groups. However, inter‑trigonal distance showed the least percentage change across the cardiac cycle and its reduced dynamism was validated in both cohorts (P > 0.05). Conclusions: Annular dimensions in regurgitant valves are dynamic and can be measured feasibly and accurately using echocardiography. The echocardiographically identified inter‑trigonal distance does not change significantly during the cardiac cycle.

SELECTION OF CITATIONS
SEARCH DETAIL