Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Korean Journal of Medical Physics ; : 30-36, 2009.
Article in Korean | WPRIM | ID: wpr-88370

ABSTRACT

The quality correction in the air kerma dosimetry for Ir-192 using farmer type ionization chambers calibrated by Co-60 quality is required. In this study we determined quality factor (kappa u) of two ionization chambers of PTW-N30001 and N23333 for Ir-192 source using dosimetric method. The quality factors for energy spectrum of microSelectron were determined as kappa u=1.016 and 1.017 for PTW-N30001 and N23333 ionization chambers respectively. We applied quality factors in air kerma dosimetry for microSelectron source and compared with reference values. As a results we found that the differences between reference air kerma rate and measured it with and without quality correction were about -0.5% and -2.0% respectively.


Subject(s)
Gamma Rays , Reference Values
2.
Korean Journal of Medical Physics ; : 131-138, 2008.
Article in Korean | WPRIM | ID: wpr-7196

ABSTRACT

We evaluated on the calculation accuracy of treatment planning system (TPS) with phantom having convex and concave surface. The TPS is Eclipse (Varian, USA) using both algorithms AAA and PBC for photon dose calculations. PBC algorithms have three corrections of Batho, modified Batho (M-Batho), and equivalent TAR (E-TAR). The field sizes were 10x10 cm2 and 20x20 cm2, and MLC-shaped fields for these fields. We measured doses at three depths 5, 10 and 15 cm in phantom of SSD=90 cm in the condition of inserted farmer chamber. For given conditions, we have calculated dose with these algorithms and compared them with measured doses. In AAA the calculated doses (dose/MU) were agreed to measured doses within +/-1% in flat and convex surface and were under estimated with -1.9% maximum in concave surface. In PBC the calculated doses were over estimated with +1.7% and +4.1% respectively in flat and convex surface and the differences were from -3.1% to +2.1% in concave surface. In comparison of criteria from AAPM and IAEA reports, and statistical analysis for these results, it is found that the AAA's results are in good agreement with measured values and the M-Batho's results are generally good agreed with measured values among PBC algorithms.


Subject(s)
Water
3.
Korean Journal of Medical Physics ; : 209-213, 2007.
Article in Korean | WPRIM | ID: wpr-213244

ABSTRACT

In this work we have measured the dose distribution and the percent depth dose of 20 MeV electron beam using the X-OMAT films in order to verify the effects of transverse magnetic field on high energy elecrtron beam in a phantom. The result shows about 30% increase of the percent depth dose at 4.5 cm depth under the transverse magnetic field of 1.5 Tesla at 7.5 cm depth. We have verified that these were in an agreement with other theoretical results.


Subject(s)
Magnetic Fields
4.
Korean Journal of Medical Physics ; : 221-225, 2007.
Article in English | WPRIM | ID: wpr-213242

ABSTRACT

Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a depth region as a target on the central axis of photon beam under moving transverse magnetic field. We have calculated the depth dose curves for two cases of moving magnetic field along a depth line, constant speed and optimal speed. We introduced step-by-step shift and time factor of the position of the electromagnet as an approximations of continuous moving. The optimal time factors as a function of magnetic field position were calculated by least square methods using depth dose data for static magnetic field. We have verified that the flat depth dose is produced by varying the speed of magnetic field as a function of position as a results of Monte Carlo calculations. For 3 T magnetic field, the dose enhancement was 10.1% in comparison to without magnetic field at the center of the target.


Subject(s)
Axis, Cervical Vertebra , Magnetic Fields , Magnets , Time Factors
5.
Korean Journal of Medical Physics ; : 111-115, 2005.
Article in Korean | WPRIM | ID: wpr-102314

ABSTRACT

We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5%, linearity was less than 0.5%, and dose rate effect was less than 0.7%. In addition the effect of dose variation from other chambers was estimated to maximum 0.8% approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.


Subject(s)
Carbon , Electrodes
SELECTION OF CITATIONS
SEARCH DETAIL