Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Acta Academiae Medicinae Sinicae ; (6): 599-601, 2014.
Article in English | WPRIM | ID: wpr-329778

ABSTRACT

<p><b>OBJECTIVE</b>To explore the usefulness of head-space gas chromatography for the determination of methanol and ethanol in Haikesu I,a raw material of artificial musk.</p><p><b>METHODS</b>The determination was performed on HP-5(30 m×0.53 mm,5 Μm)capillary column with an hydrogen flame ionization detector. The solvent was dimethyl sulfoxide and the internal standard was acetone. The injector temperature and the detector temperature were controlled at 180 ℃ and 250 ℃,respectively. The carrier gas was nitrogen. The containers of head-space injector were preheated at 90 ℃ for 15 minutes. The column temperature was programmed raised,which achieved baseline separation of the components.</p><p><b>RESULTS</b>The results showed a good linear relationship for methanol and ethanol in their linearity range;and the limit of detection was 0.8 and 1.0 Μg/ml,respectively. The precision and average recoveries were satisfactory.</p><p><b>CONCLUSION</b>The head-space gas chromatography is simple,rapid,and precise technique for the measurement of residual solvents in Haikesu I.</p>


Subject(s)
Acetone , Chromatography, Gas , Drugs, Chinese Herbal , Chemistry , Ethanol , Flame Ionization , Methanol , Solvents
2.
Acta Academiae Medicinae Sinicae ; (6): 602-605, 2014.
Article in English | WPRIM | ID: wpr-329777

ABSTRACT

<p><b>OBJECTIVE</b>To determine ethylacetate and petroleum ether(60-90 ℃)in Haikesu 2,which is one of the raw materials of artificial musk,using the head-space gas chromatography.</p><p><b>METHODS</b>The determination was performed on HP-5(30 m×0.53 mm,5 Μm)capillary column with an hydrogen flame ionization detector. The solvent was dimethyl sulfoxide and the internal standard was methanol. The injector temperature and the detector temperature were controlled at 180 ℃ and 250 ℃,respectively. The carrier gas was nitrogen. The containers of head-space injector were preheated at 90 ℃ for 15 minutes. The column temperature was programmed raised,which achieved baseline separation of the components.</p><p><b>RESULTS</b>The results showed a good linear relationship for ethylacetate and petroleum ether(60-90 ℃)in their linearity range;and the limit of detection was 0.7 and 0.3 Μg/ml,respectively. The good precision and good average recoveries were satisfactory.</p><p><b>CONCLUSION</b>The head-space gas chromatography is simple,rapid,and precise technique for the measurement of residual solvents in Haikesu 2.</p>


Subject(s)
Acetates , Chromatography, Gas , Drugs, Chinese Herbal , Chemistry , Fatty Acids, Monounsaturated , Chemistry , Flame Ionization , Solvents
3.
Chinese Acupuncture & Moxibustion ; (12): 269-270, 2011.
Article in Chinese | WPRIM | ID: wpr-271156

ABSTRACT

By consulting the literatures relevant with the prevention and treatment of human rabies from Tang Dynasty to Qing Dynasty, it was discovered that rabies was caused by wind toxin in mad dog injuring human being. The pathogenesis of rabies was the invasion of dog toxin into the heart. The latent period was ranged from 7 to 100 days. Acupuncture-moxibustion, bloodletting, cupping and other therapies could be used in treatment. But of those different therapies, the various moxibustion methods achieved unique efficacy on the disease.


Subject(s)
Humans , Acupuncture Therapy , Moxibustion , Prognosis , Rabies , Therapeutics
SELECTION OF CITATIONS
SEARCH DETAIL