Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Asian Pacific Journal of Tropical Medicine ; (12): 53-56, 2013.
Article in English | WPRIM | ID: wpr-820568

ABSTRACT

OBJECTIVE@#To observe the effects of sevoflurane treatment on lung inflammation in rats with lipopoIysaccharide-induced acute lung injury (ALI).@*METHODS@#The rat model of ALI was established by intratracheal instillation of lipopolysaccharide (LPS). 45 infantile SD rats [body weight (272±15) g] were randomly divided into 3 groups (n=15): control group, LPS group, sevoflurane group. NS (1 mL/kg) was instillated in rats' airways of control group; LPS (5 mg/kg) was instillated in rats' airways of LPS group. Sevoflurane group rats received sevoflurane (2.4%) inhalation for a hour after LPS was instillated in rats' airways. Six hours after NS or LPS instillation, all rats were exsanguinated. Lung tissues were examined by HE staining. Expressions of TNF-α and ICAM1 mRNA were detected by semiquantitative RT-PCR techniques. The protein level of TNF-α and ICAM1 were assessed by western blot techniques.@*RESULTS@#In LPS group the permeability of lung tissues increased, organizational structure severely damaged and the alveolar wall tumed thick, with interstitial edema and Europhiles infiltrated increasingly. The LPS group had higher mRNA expressions of TNF-α and ICAM1 than control group and sevoflurane group (P<0.05), and LPS group had higher protein level of TNF-α and ICAM1 than control group and sevoflurane group (P<0.05).@*CONCLUSIONS@#Sevoflurane treatment can attenuate lung inflammation in rats with lipopolysaccharide-induced acute lung injury.


Subject(s)
Animals , Male , Rats , Acute Lung Injury , Metabolism , Pathology , Administration, Inhalation , Gene Expression , Allergy and Immunology , Intercellular Adhesion Molecule-1 , Genetics , Metabolism , Lipopolysaccharides , Lung , Chemistry , Metabolism , Pathology , Methyl Ethers , Pharmacology , Pneumonia , Drug Therapy , Metabolism , Pathology , Protective Agents , Pharmacology , Random Allocation , Rats, Sprague-Dawley , Sevoflurane , Tumor Necrosis Factor-alpha , Genetics , Metabolism
2.
Academic Journal of Second Military Medical University ; (12): 343-345, 2001.
Article in Chinese | WPRIM | ID: wpr-736846

ABSTRACT

Objective: To establish a curve of dosage gradient-liver signal intensity of superparamagnetic iron oxide (SPIO) in normal rats and to find an appropriate dose for enhancement. Methods: Seventy-two SD rats, 4 rats a group at random, underwent MR enhancement with 0, 2, 5, 8, 10, 12, 15, 20, 30, 40, 50, 60, 70, 80, 100, 140, 210, 280 μmol/kg SPIO respectively after plane examination. The signal-to-noise ratio of liver was measured and a curve of dosage gradient-liver signal intensity was made. Results: (1)With the increase of SPIO dose, the signal intensity of both T1 and T2 weighted images of liver declined. (2)T2 weighted images was more sensitive than T1 weighted images in small dose, the ED50 of T1 weighted was 8 μmol/kg, and the ED50 of T2 weighted was 5 μmol/kg. (3)When the dose was greater than 15 μmol/kg, the signal intensity of T1 weighted images declined more rapidly than T2 weighted, the effect of enhanced T1 weighted images resembled T2 weighted ones, and its images was with more fine resolution. (4)At the dose of 40 μmol/kg, the signal intensity of T1 weighted images approached the background noise, and at the dose of 15 μmol/kg, the signal intensity of T2 weighted images approached the background noise. Conclusion: Good effect of T1 and T2 enhanced MR imaging can be acquired at the dose of 20-10 μmol/kg SPIO respectively, the best contrast-to-noise ratio is found on T2 weighted enhanced MR image.

3.
Academic Journal of Second Military Medical University ; (12): 343-345, 2001.
Article in Chinese | WPRIM | ID: wpr-735378

ABSTRACT

Objective: To establish a curve of dosage gradient-liver signal intensity of superparamagnetic iron oxide (SPIO) in normal rats and to find an appropriate dose for enhancement. Methods: Seventy-two SD rats, 4 rats a group at random, underwent MR enhancement with 0, 2, 5, 8, 10, 12, 15, 20, 30, 40, 50, 60, 70, 80, 100, 140, 210, 280 μmol/kg SPIO respectively after plane examination. The signal-to-noise ratio of liver was measured and a curve of dosage gradient-liver signal intensity was made. Results: (1)With the increase of SPIO dose, the signal intensity of both T1 and T2 weighted images of liver declined. (2)T2 weighted images was more sensitive than T1 weighted images in small dose, the ED50 of T1 weighted was 8 μmol/kg, and the ED50 of T2 weighted was 5 μmol/kg. (3)When the dose was greater than 15 μmol/kg, the signal intensity of T1 weighted images declined more rapidly than T2 weighted, the effect of enhanced T1 weighted images resembled T2 weighted ones, and its images was with more fine resolution. (4)At the dose of 40 μmol/kg, the signal intensity of T1 weighted images approached the background noise, and at the dose of 15 μmol/kg, the signal intensity of T2 weighted images approached the background noise. Conclusion: Good effect of T1 and T2 enhanced MR imaging can be acquired at the dose of 20-10 μmol/kg SPIO respectively, the best contrast-to-noise ratio is found on T2 weighted enhanced MR image.

SELECTION OF CITATIONS
SEARCH DETAIL