China Medical Equipment ; (12): 108-110, 2016.
Article in Chinese | WPRIM | ID: wpr-498593

ABSTRACT

Objective:To provide informational and personalized health service platform for the current number of chronic diseases and health groups. Methods:a variety of portable devices physiological data were collected to transmit to the remote health monitoring platform, making the service with strong mobility for home care, postoperative care and patient care whenever and wherever needed to provide the best care service model, so that medical and health care is no longer subject to the constraints of time, hospitals and other fixed places. Results: Through a variety of wireless transmission technology and the intelligent terminal and regional health data center, it can be further mining, analysis and storage for the data information, and provide diagnostic advice. It can effectively alleviate the tension of medical resources. Conclusion:The establishment of remote health monitoring platform can alert doctors and relatives when data is abnormal to win time for rescue. It can effectively manage the disease treatment, prevention and rehabilitation.

2.
China Medical Equipment ; (12): 31-34, 2016.
Article in Chinese | WPRIM | ID: wpr-496218

ABSTRACT

Objective:To evaluate the performance for the Sysmex XN20 A1 automation blood cell analyzer.Methods: The precision, contaminative rate, linear range, blank, accuracy and various sample models were verified, and low values of blood platelet were compared with the methods of microscopy and dye.Results:The contaminative rate was lower than 0.4%. The linear arrange and precision were well for the analyzer. The values of RBC, HGB and PLT were within the range of 1±0.05 and the correlation coefficients were higher than 0.975. The bias of average and constant values by the accuracy verification samples test met the demands of accuracy. And the relative differences of various sample models meet the requirements of the comparability. The variable coefficient of low values of PLT was lower than 4% by the dye method.Conclusion: The Sysmex XN20 A1 automation blood cell analyzer has the characteristics of perfect precision, accuracy, low contaminative rate, broad linear arrange and good repeatability for the low level PLT. It can be applied in clinical laboratory.

SELECTION OF CITATIONS
SEARCH DETAIL