Chinese Journal of Comparative Medicine ; (6): 58-61, 2015.
Article in Chinese | WPRIM | ID: wpr-463180

ABSTRACT

Objective To establish the amplified luminescent proximity homogeneous assay(AlphaLISA) for the detection of Sendai virus.Methods The antigen concentration,serum concentration and the donor beads/acceptor beads ratio used in the AlphaLISA method were optimumized by the phalanx experiments, then the antibodies of Sendai Virus in 40 rat sera were detected by the established AlphaLISA method and ELISA detection method.The results were compared and the differentia between the two methods was confirmed by IFA.Results The optimum concentration of SV bio-peptide in AlphaLISA assay was 250 nmol/L, the best proportion of donor beads/acceptor beads ratio was 1 ∶1, using the concentration of 20 μg/mL and the serum dilution was 1∶10000.7 of the 40 rat sera were detected SV positive by ELISA, the positive rate was 17.5%, 8 of the 40 rat sera were determined SV positive by AlphaLISA, and the positive rate was 20.0%, the AlphaLISA positive serum was confirmed by IFA.Conclusions We preliminary established the Amplified Luminescent Proximity Homogeneous Assay(AlphaLISA) for the detection of Sendai virus.The sensitivity of the method is comparable to classical ELISA method, but this method use less serum samples and without washing steps.The method has some advantages in degeneracy and accuracy.

2.
Chinese Journal of Analytical Chemistry ; (12): 1706-1709, 2014.
Article in Chinese | WPRIM | ID: wpr-460052

ABSTRACT

Aninductivelycoupledplasmamassspectrometric(ICP-MS)methodbasedonquadrupole reaction/collision ( DRC) was developed for the determination of K,Na,Ca,Mg,Al,Cu,Zn,Pb,As and Mn in food. Samples were digested with HNO3 and H2 O2 followed by dilution with ultrapure water and then analyzed directly by ICP-MS. The signal sensitivity of high concentration element ( K, Na, Ca, Mg and Al ) was suppressed easily by adjusting the voltage parameters of DRC quadrupole ( Rpa) , and the food samples could be online diluted any multiples ( i. e. from one time to million times) according to the actual need. In order to eliminate mass spectral interferences of 40 Ar35 Cl+, the operational conditions of the DRC, working with CH4 as reaction gas, were optimized for 75 As. The limits of detection for the K, Na, Ca, Mg, Al varied from 0. 013-0. 027 mg/L, and Cu, Pb, Zn, As, Mnvaried from 0. 12-0. 61 μg/L. The accurate and reliable results were obtained for validation of the ICP-MS method with food reference material according to the national standard GBW10023 , GBW10015 , GBW10018 , GBW10017 , GBW10019 and GBW10024 . As the routine method in our laboratory, the satisfactory results indicate that it has great potential for the determination of low and high concentration level elements by one single analysis in various samples.

SELECTION OF CITATIONS
SEARCH DETAIL