Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Health ; (6): 46-50, 2024.
Article in Chinese | WPRIM | ID: wpr-1012769

ABSTRACT

Objective To summarize and analyze the difficulties and key points in the measurement of gross α and gross β radioactivity in water based on the results of national measurement capability comparison assessment, and provide the basis and reference for the future work and the development of new local standards. Methods The research team participated in the comparison assessment for measurement of the gross radioactivity in water samples organized by National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention. According to the comparison assessment results and the content in the national standard GB/T 5750.13—2023 (published draft), the steps of spike recovery involved during the measurement were analyzed and discussed. Two different formulas used for spike recovery calculation were analyzed for their impact on the final measurement results. Results When the spike recovery F(derived) derived from the formulas was used for result calculation, the spike recovery ranged as follows: gross α: 63.00%−84.60%, and gross β: 95.0%−99.1%; 3/6 of the comparison results were determined as excellent and 3/6 as pass as a whole (among them, 4 were excellent and 2 were pass for both single gross α assessment items and single gross β assessment items). When the spike recovery F from the GB/T 5750.13—2023 (published draft) was used for result calculation, the spike recovery ranged as follows: gross α: 39.69%−71.57%, and gross β: 90.25%−98.21%; 5/6 of the comparison results were determined as fail and 1/6 as pass (among them, 5 were fail and 1 was pass for single gross α assessment items; 5 were excellent and 1 was pass for single gross β assessment items). When two different formulas were used for spike recovery calculation, there was a significant difference in gross α radioactivity measurement (t = 4.27, P = 0.03 < 0.05), but there was no significant difference in gross β radioactivity measurement (t = 0.667, P = 0.524 > 0.05). Conclusion In the measurement of gross α and gross β radioactivity in water, appropriate reference to the spike recovery has a great influence on the measurement results. Therefore, quality control should be strengthened to further ensure the accuracy of measurement.

SELECTION OF CITATIONS
SEARCH DETAIL