Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Education Research ; (12): 1382-1386, 2021.
Article in Chinese | WPRIM | ID: wpr-931289

ABSTRACT

Objective:To investigate the attitudes and demands of medical students on medical education rituals in the context of the new era, to find out the existing problems, and to provide reference to the innovation and improvement of the rituals.Methods:An online questionnaire was conducted among medical students. SPSS 25.0 was used for descriptive statistical analysis and rank sum test of the data. Qualitative research methods such as in-depth interviews and panel discussions were used to comprehensively analyze the qualitative data.Results:"Post-00s" medical students, who are known as the aborigines of the Internet, are also looking forward to the return of traditional medical education rituals. Compared with junior students, senior students had lower awareness of the importance of rituals and lower willingness to participate in rituals, and the degree of professional identity arousal by the rituals was also lower ( P<0.05). Certain medical students indicated that they had never participated in medical education rituals, and some indicated that their specialties were not valued in the rituals. Conclusion:Medical education in the new era should revive traditional rituals and be adjusted to the changes in the background of the times and the characteristics of the student groups. The current ritual education fails to meet the needs of medical students at different stages, and its systematicness and continuity should be strengthened. The coverage of medical education rituals for medical students is incomprehensive and uneven, and it is necessary to further expand the coverage and appropriateness of rituals in medical-related specialties and fully consider the characteristics of each specialty in medical students.

2.
Journal of China Pharmaceutical University ; (6): 322-327, 2017.
Article in Chinese | WPRIM | ID: wpr-617552

ABSTRACT

To establish an HPLC method to determine osimertinib mesylate,Agilent ZORBAX Eclipse Plus C18 column (4.6 mm × 250 mm,5 μm) was used with a mobile phase consisting of methanol-buffer solution (20 mmoL/L NaH2PO4,pH 3.0 adjusted with 85% H3PO4) (50 ∶ 50) at the flow rate of 1.0 mL/min.The detection wavelength was 210 nm,and the column temperature was kept at 35 ℃.The calibration curve was liner over the range from 50% to 150% of determination concentration (0.201 1-0.603 2 mg/mL,r =0.999 9).The limit of quantitation (LOQ) and limit of detection (LOD) were 0.32 μg/mL and 0.08 μg/mL,respectively.The contents of osimertinib mesylate in samples were 100.1%,99.5% and 99.7%.Good chromatographic separation of osimertinib mesylate and its related substances,including synthetic impurities and degradation products,were obtained.The established HPLC method is specific,accurate,simple and durable,and could be used for the determination of osimertinib mesylate.

3.
Journal of China Pharmaceutical University ; (6): 421-425, 2015.
Article in Chinese | WPRIM | ID: wpr-811968

ABSTRACT

@#An improved manufacturing process for rivastigmine(1)was developed by performing the condensation reaction of m-hydroxyacetophenone(4)with N-ethyl-N-methyl carbamoyl chloride, then Corey-Bakshi-Shibata(CBS)chiral reduction to(R)-3-(1-hydroxyethyl)phenyl ethyl(methyl)carbamate(2)and then mesylation with methanesulfonyl chloride and nucleophilic substitution with dimethylamine, respectively. To be successful, a crucial reductive process in the conversion of ketone(3)to chiralalcohol(2)had to be correctly understood and optimized via orthogonal experiment. The whole improved process was convenient for operation and purification, with completion of the synthesis of rivastigmine and an overall yield of 88%.

4.
Acta Anatomica Sinica ; (6): 157-159, 2010.
Article in Chinese | WPRIM | ID: wpr-404317

ABSTRACT

Objective Measuring the displacement and deformation of the fifth screw under different tensile force before or after adultal internal fixation with compressing steel plate for femoral fractuer by digital speckle correlation method.And analysis of the displacement and deformation after reducing the number of screws.Aimed at providing a theoretical basis for clinical femoral internal fixation with compressing steel plate about the number of screws. Methods Taking the antisepsis femoral specimen of grown-ups, embedding and fixing with tooth powder after removing the soft tissue, producing a fixed model in the 1/2 femur.Fixing steel plate below the lateral femur subperiosteal with five screws through the fourth floor of cortical bone on both sides of the fractures, samples were divided into 10 states, group A-J were measured by orders, under the rally of 400 N,500N , measuring the displayment of the fifth screw with CSS-44100-e-universal test machine for loading rally experiment ,and automatic data processing. Results For analysis of variance, the mean displacement measurements of the fifth screw under rally of 400N,500N, B-J group and A group have significant differences(P<0.05). The mean deformation measurements of the fifth screw under rally of 400N,500N, group A and group F-J group have significant differences(P<0.05);group A and B-E group have no significant differences.Conclusion In a certain range, the fracture displacement and the numuber of the screws show negative correlation. The screws near the fracture line for femoral compression plate internal fixation of femoral fractuer is easily broken because of the too large deformation.

SELECTION OF CITATIONS
SEARCH DETAIL