Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Analytical Chemistry ; (12): 350-355, 2015.
Article in Chinese | WPRIM | ID: wpr-461362

ABSTRACT

A new type of surface plasmon resonance ( SPR) spectroscopy system was designed and built. Here, a kind of dual photocell sensor was developed as a detection device to achieve a rapid measurement of SPR angle within a certain range. This SPR system was combined and integrated with electrochemical workstation to obtain a new type of electrochemistry-time-resolved SPR ( EC-TR-SPR ) instrument via instrumental technique. This EC-TR-SPR instrument was used to characterize the electrochemical polymerization process of aniline to validate the spectroscopic characteristics. Applications of transient electrochemical characterization methods, including chronoamperometry and differential pulse voltammetry, confirmed the time resolution and the applicability of this instrument system toward the steady state and transient electrochemical methods upon small molecular reactions. The experiment results showed that this EC-TR-SPR possessed the time resolution up to 10000 times per second (0. 1 ms), and could be used to real-time investigate the doping and de-doping of polymerization process of aniline monomer as well as the prepared polyaniline film, which could not be discriminated on a conventional electrochemical current-time curve. .

2.
Chinese Journal of Digestive Surgery ; (12): 770-773, 2013.
Article in Chinese | WPRIM | ID: wpr-442416

ABSTRACT

Objective To investigate the value of narrow band imaging (NBI) and lugol chromo-endoscopy (LCE) in the diagnosis of advanced esophageal carcinoma.Methods The clinical data of 162 patients with advanced esophageal carcinoma who received NBI and LCE at the Cancer Hospital of Peking University from November 2010 to May 2012 were retrospectively analyzed.Esophageal mucosa was first examined using white light imaging (WLI),and then followed by NBI and LCE,and the lengths of the lesions were recorded.Biopsy histology was obtained in all abnormal mucosa which were detected by NBI or LCE.Difference in the length of lesions detected by the NBI/LCE and WLI was calculated.Surgical approach and method of anastomosis were recorded for patients who received surgical treatment,and the final treatment method was recorded for patients who did not receive surgical treatment.Difference in the treatment methods was compared before and after endoscopy.Results The length of the lesions detected by the 3 methods was identical in 121 patients,different in 41 patients.The difference ranged between 1 and 3 cm was observed in 22 patients,>3 cm and ≤5 cm in 8 patients,>5 cm and ≤10 cm in 7 patients,> 10 cm in 4 patients.Of the patients in the above mentioned 4 categories,there were 1,2,2,4 patients in each category received neo-adjuvant therapy,and the rest patients received operation.Superficial cancer contiguous to the primary lesion was found in 41 patients,including squamous cell carcinoma in 31 patients,carcinoma-in-situ in 3 patients and severe dysplasia in 7 patients.Of the 153 patients who received surgery,the surgical plan for 12 patients was modified.Intrathoracic anastomosis was changed to cervical anastomosis in 2 patients,anastomosis under the aortic arch was changed to anastomosis above the aortic arch in 3 patients,trans-abdominal operation was changed to thoraco-abdominal operation in 7 patients.Conclusions The combination of NBI and LCE is more accurate to evaluate the extent of lesions of advanced esophageal carcinoma,and is useful to decide the treatment protocol.Pathological examination of the adjacent abnormal mucosa should be carried out for patients whose lesion length was inconsistent under different observation methods.

3.
Chinese Journal of Digestion ; (12): 509-513, 2012.
Article in Chinese | WPRIM | ID: wpr-419749

ABSTRACT

Objective To investigate the clinical efficacy of covered self-expanding metal stent in the treatment of malignant esophageal stricture.Methods The clinical data of 512 patients accepted stent were retrospectively analyzed,which included patients' profiles,relief of dysphagia,incidence of complications and survival period.The data were analyzed by t test.Results A total of 596 stents were placed in 512 patients.There was significant difference in mean dysphagia score between before and after stent placement (grade 3.4±0.6 vs grade 1.1±0.8,t=54.09,P<0.01).After the placement,the overall incidence of complications was 14.5% (74/512),of which there were 21 cases of severe retrosternal pain (4.1%),16 cases of bleeding (3.1 %),29 cases of stent displacement (5.7%),six cases of food impaction (1.2%),two cases of fistula without completely blocked (0.4%).The survival period of 238 patients with complete follow-up ranged from 30 to 1445 days,the mean time was 218.9 days.Conclusion Endoscopic covered self-expanding metal stent placement may effectively relieve dysphagia symptoms in patients with malignant esophageal stricture.

SELECTION OF CITATIONS
SEARCH DETAIL