Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 786-790, 2014.
Article in Chinese | WPRIM | ID: wpr-466109

ABSTRACT

Objective To investigate the value of contrast-enhanced ultrasound (CEUS) in diagnosis of renal epithelioid angiomyolipoma (eAML).Methods The CEUS features of 18 patients with 18 histopathologically proved renal eAMLs were retrospective analyzed using both of qualitative and quantitative approachs.Tumor conventional ultrasound and CEUS features were observed.The Sonoliver software was applied to perform quantitative analysis,which provided five parameters,including the maximum intensity (IMAX),rise time (RT),time to peak (TTP),mean transit time (mTT) and area under the curve (AUC).Results All of 18 lesions were pathological proved as eAML,among them,heterocyst was observed in 7 lesions,1 lesion had dissemination inter-kidney and vessel invasion,necrosis or cystic degeneration was found in 3 eAMLs.On conventional ultrasound,eAML showed hypoecho,isoecho and hyperecho were 14(77.8%),3(16.7%) and 1 (5.6%) respectively.Blood flow could be detected in 16 (88.9%) lesions.On CEUS,the characters of slow-in,synchronous-in,slow centripetal enhancement and entire enhancement were observed in 10 (55.6%),8 (44.4%),8 (44.4%) and 12 (55.6%) lesions,respectively.Most of eAMLs showed homogeneous enhancement (15/18,83.3%) and hyper-or iso-enhancement (16/18,88.8 %) at peak time.The characters of fast-out,synchronous-out and slow out were observed in 8 (44.4%),2 (11.2%) and 8 (44.4%) cases,respectively.Pseudocapsule was detected in 5 (27.8%) lesions.The parameters of RT,TP and AUC for eAMLs were higher than that for renal cortex (P < 0.05),while the parameters of IMAX and mTT had no significant statistical difference between eAMLs and renal cortex(P >0.05).Conclusions Qualitative and quantitative analysis of CEUS reflect the blood perfusion of eAMLs in different aspect,which offer some useful informations for the diagnosis of eAMLs.

2.
Chinese Journal of Ultrasonography ; (12): 496-499, 2013.
Article in Chinese | WPRIM | ID: wpr-434825

ABSTRACT

Objective To investigate the viability of analysis of hemodynamic changes with color Doppler flow imaging in the prediction of acute rejection in transplanted liver.Methods Sixty-eight patients enrolled in the study were categorized into three groups:transplanted liver without acute rejection [rejection activity index(RAI) 0-3,n =24],transplanted liver with mild acute rejection (RAI 4-5,n =23),transplanted liver with moderate and severe acute rejection (RAI 6-9,n =21).All the patients were confirmed by pathology.The color Doppler flow imaging were performed in all the patients within 24 hours and 1 week after biopsy.Results In transplanted liver with moderate and severe acute rejection,the peak systolic velocity of portal vein (PV-PSV) was (31.4 ± 14.1)cm/s,significantly lower than that in transplanted liver without acute rejection,which was (45.1 ± 17.7)cm/s (P <0.05).A week later after steroid therapy,the PV-PSV in transplanted liver with moderate and severe rejection was increased to (46.7 ± 21.8)cm/s(P <0.05).Patients with acute rejection were associated with the decrease of the PVPSV (P <0.05).Conclusions The decrease of PV-PSV may have some clinical value in evaluation the acute rejection in transplanted liver.

3.
Chinese Journal of Ultrasonography ; (12): 526-528, 2012.
Article in Chinese | WPRIM | ID: wpr-426047

ABSTRACT

ObjectiveTo investigate the influence of different depths and mediums on tissue stiffness measurement by virtual touch tissue quantification technology.Methods Four kinds of in vitro porcine tissue were recruited,three (fat,muscle and liver) were assigned as medium group and three (kidney,liver and muscle) as sample group.The shear wave velocity (Vs) of the samples was measured under different mediums and at different depths (2 cm,3 cm,4 cm and 5 cm),respectively.ResultsAccording to the depth of measurement,two groups of Vs were defined with one group at the depth of 2 cm and 3 cm while the other at 4 cm and 5 cm.The difference of Vs between the two groups was of statistical significance and with the increase of the depth Vs values decreased.Even at the same depth,the differences of Vs under different mediums were statistically significant.ConclusionsDepths and mediums have great influence on evaluating elasticity measurements by virtual touch tissue quantification technology.

SELECTION OF CITATIONS
SEARCH DETAIL