Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add filters








Language
Year range
1.
Chinese Journal of Microsurgery ; (6): 338-341, 2015.
Article in Chinese | WPRIM | ID: wpr-483144

ABSTRACT

Objective To explore the feasibility and clinical effect of modified peroneal artery perforatorbased propeller flap which excludes small saphenous vein and sural nerve for coverage of the soft tissue defects of the ankle and foot.Methods From January,2009 to August,2013,20 patients with soft tissue defects of the foot or ankle underwent the procedures of reconstruction.After the proper perforators being identified with doppler sonography,the propeller flap was designed,which selected the location where terminal perforator vessels perforate deep fascia as the pivot point,the line from this point to the point where the second perforator near the wound around the line from the midpopliteal point to the midpoint of the achilles tendon and lateral malleolus perforated the deep facia as the axis.The flap was raised above the level of the deep fascia.The small extrinsic vessels around the sural nerve and small saphenous vein were contained in the flap,while the small saphenous vein and sural nerve were kept in the original position.The donor site was closed directly.The skin flaps measured from 7 cm × 4 cm to 21 cm × 7 cm.Results All 20 flaps survived completely without complications.During 10-28 months' followed-up (average 13 months),all flaps showed good texture matches and contour.All patients recovered walking and shoe wearing function.No one showed sensory disturbances at the lateral foot.Conclusion The modified peroneal artery perforator-based propeller flap excluding small saphenous vein and sural nerve still has stable blood supply,which is an idea way for covering skin and soft tissue defects in foot and ankle.

2.
Chinese Journal of Microsurgery ; (6): 526-529, 2015.
Article in Chinese | WPRIM | ID: wpr-488993

ABSTRACT

Objective To describe a technique to achieve primary donor-site closure, extend applications and minimize donor-site morbidity by applying the double skin paddle principle.Methods All 16 cases of the double skin paddle anterolateral thigh perforator flap reconstruction from May, 2008 to June, 2014 were reviewed.Defects locations included calf, dorsum pedis or planta pedis.A long anterolateral thigh perforator flap was marked out using standard points of reference.At least two separate cutaneous perforator vessles were identified on hand-held Doppler.Separating and dissecting flap at superficial layer of fascia lata was adopted in all cases.Then skin paddle was then divided between the two cutaneous perforators to give two separate paddles with a common vascular supply which was the descending branch of the lateral circumflex femoral artery.The skin paddles could be used to cover complex skin defects, whilst still allowing for primary donor-site closure.Results Fifteen patients were successfully treated with the double skin paddle anterolateral thigh perforator flap with no major complications.One case was suffered with partial skin flap necrosis.The type A dumbbell-like flaps was used to cover defects involving two different units of the foot.The type B pattern were stacked side by side on a flap inset, effectively doubling the width of the flap, to resurface a large defect of a single unit of the calf.The type C pattern was used to repair adjacent skin defects.In all cases, the donor site was closed directly.All patients were satisfied with their outcomes.Conclusion The double skin paddle anterolateral thigh perforator flap is an excellent method of resurfacing large defects of the extremity involving multiple subunits with improved morbidity and cosmesis of the donor site.

3.
Chinese Journal of Trauma ; (12): 1085-1088, 2014.
Article in Chinese | WPRIM | ID: wpr-469543

ABSTRACT

Objective To investigate the clinical results,indications and precautions of a variety of special forms of the perforator flap for reconstructing limb soft-tissue defect.Methods From January 2008 to December 2013,480 cases suffering from limb soft-tissue defect were treated with special forms of the perforator flap.Types of special forms of the perforator flap included flow-through perforator flaps,micro-dissected perforator flaps,conjointed perforator flaps,polyfoliate perforator flaps and chimeric perforator flaps.Derivative types combined two or three technologies used in basic types.Results Venous crisis of the flap was shown in 10 cases.Through a second surgical exploration,5 cases were diagnosed with anastomotic thrombosis,2 with vascular torsion and 3 with hematoma.After appropriate treatments,flaps survived in 4 cases,but partial necrosis occurred in 6 cases.Twelve cases were found to have infection,which led to arterial crisis followed by total flap necrosis in one of them at postoperative day 5.Other flaps survived and wounds healed by first intention.Donor sites were repaired by skin flap transfer in 8 cases,skin grafting in 3 cases and direct suture in the rest cases.Conclusion Special forms of the perforator flap are optimal for repair of soft-tissue defect of extremities.

4.
Chinese Journal of Microsurgery ; (6): 524-527, 2014.
Article in Chinese | WPRIM | ID: wpr-469316

ABSTRACT

Objective To explore the clinical effect and experience of separating deep circumflex iliac artery osteocutaneous perforator flap (DCIAP) from the bone flap.Methods According to local applied anatomy of groin,vascularized chimerical flaps of deep iliac circumflex artery was designed and applied.From May,2008 to June,2012,12 patients who combined bone and composite skin and soft-tissue defects were positioned by color dopplar ultrasound before operation and treated with vascularized chimerical flaps of deep iliac circumflex artery.The deep circumflex iliac perforator flaps was 8 to 19 cm in length and 2 to 6 cm in width,and the iliac bone grafts ranged from 5 to 8 cm in length.Results All flaps were fully survival.After 8-10 months postoperative followed-up,all the bone defect gained healing.The function and appearance of cutaneous flaps were satisfactory.There was no serious complication in donor sites of groin.The average time of healing was 9 (8-10) months.Conclusion Vascularized iliac bone graft and a perforator flap are nourished by the same deep circumflex iliac artery.There is more mobile scope and only 1 blood vessel between the bone graft and skin flap,which should be called chimeric perforator flap based on the deep iliac circumflex artery,and is a kind of good method to repair bone and soft-tissue defects of limbs.

5.
Chinese Journal of Microsurgery ; (6): 449-452, 2014.
Article in Chinese | WPRIM | ID: wpr-469298

ABSTRACT

Objective To explore the safety and clinical effect of the human acellular nerve allograft (hANG) for repairing peripheral nerve defects.Methods During November,2009 to October,2010,6 patients with 3 digital nerve defects and 3 radial nerve defects were repaired with hANG.During postoperation period,safety was evaluated by local wound response and laboratory testing,while the efficacy was evaluated by British Medical Research Council sensory function assessment standards,static 2-point discrimination (2PD) and Semmes-Weinstein monofilament testing.Results Three patients with 6 digital nerve defects received hANG transplant.The length of nerve graft was 20-50 mm(mean 30.8 mm).After followed up for 31-40 months,the excellent rate of 2PD was 66.7%.Two of 3 patients rahabilited as well as the normal.Three patients with radial nerve defects,whose length of nerve graft was 35-60 mm(mean 48.3 mm).The strength of extensor carpiradialis longus muscle had restored Ⅲ in 1 case,and other 2 cases had no restoration.Conclusion hANG is safe and effective for repairing peripheral nerve defects,especially for digital nerve defects.

6.
Chinese Journal of Microsurgery ; (6): 211-214, 2013.
Article in Chinese | WPRIM | ID: wpr-436520

ABSTRACT

Objective To explore the feasibility and clinic outcome of the modified latissimus dorsi flap when it is used to repair huge soft tissue defects in lower limbs.Methods The latissimus dorsi muscle is rich blood supply and available for harvest huge areas.According to these characteristics the modified latissimus dorsi flap was designed:a limited latissimus dorsi skin flap with a large area of latissimus dorsi muscle flap,skin graft area was transferred from donor-site to recipient-site.From April 2009 to August 2011,ten patients with large soft tissue defects in lower limbs were treated with modified latissimus dorsi flap.The size of skin and soft tissue defects range from 19 cm × 10 cm to 32 cm × 16 cm.Ten modified latissimus dorsi flaps had been used for coverage of these wounds,which were amplified 1-2 cm compared with the corresponding wounds.The size of skin flap was 20 cm × 6 cm-33 cm × 10 cm which was allowable to get direct closure of donor-site wounds.Results All the flaps and skin graft survived completely with no complication.Donor-site and recipient-site were primary closed and healing in all patients.All of the patients had got follow-up from 6 months to 36 months.All flaps survived with excellent color and quality,and no extremely fat contour.The results in donor site were satisfying and only left liner scar.It has no effect in the shoulder function.Conclusion The modified latissimus doris flap can provide with a huge amount of skin and soft tissue and be designed in various ways.It is a safe and reliable way to reconstruct huge skin and soft tissue defect in lower limbs.

7.
Chinese Journal of Microsurgery ; (6): 186-189,后插1, 2010.
Article in Chinese | WPRIM | ID: wpr-571577

ABSTRACT

Objective To explore the clinical outcome of perforator flaps for reconstruction of limb soft tissue defects. Methods In this case series, from 2007 July to 2009 May, 108 cases of perforator flap to reconstruct the defects of the extremities were performed, of these, 98 were free perforator flaps, 10 were pedicled flaps. The perforator flaps included deep inferior epigastric artery perforator flap, anterolateral thigh perforator flap, thoracodorsal artery perforator flap, lateral thigh perforator flap, posterior interosseous artery perforator flap, collateral radial artery perforator flap, medial sural artery perforator flap, posterior tibial artery perforator flap, deep circumflex iliac artery perforator flap and peroneal artery perforator flap. The maximum size of the perforator flap was 44 cmx 9 cm, the minimum size of the perforator flap was 4 em x 2 cm.The donor defect was closed directly. Results Venous congestion occurred in 5 flaps, in 1 case venous congestion was overcomed after released the dressing, 4 flaps requiring reexploration for venous insufficiency,2 had a successful outcome, the other 2 flaps failed . The other 103 flaps were successful. The wounds healed without any infection complications. The follow-up ranges from 6-24 months( 10 months on average). The flaps were of good appearance and not bulky; there were only linear scars on the donor sites, the cosmesis and function of the donor sites were satisfying. Conclusion The muscle, deep fascia and motor nerve are not contained in the flap, the advantages of this type of flap is reducing morbidity of the donor site and its reliable blood supply and suitable thickness for resurfacing, no secondary debuiking is necessary. The perforator flaps can be chosen as the first option to deal with superficial extremity wounds.

8.
Journal of Central South University(Medical Sciences) ; (12): 667-671, 2009.
Article in Chinese | WPRIM | ID: wpr-406279

ABSTRACT

Objective To evaluate the effect of abducens orthosis combined with walker on de-velopmental dysplasia of the hip ( DDH ). Methods A total of 126 patients (224 hips ) with DDH aged 6~36 months in Xiangya Hospital was randomly divided into 2 groups: an orthosis combined with walker group and an improved hip frog cast fixation group. Seventy patients (130 hips) were treated by the orthosis combined with walker and 56 patients (94 hips) were treated by the improved hip frog cast fixation. We compared the effect and complications of the 2 groups. Results The fine-ness rates of the orthosis combined with walker group and the improved hip frog cast fixation group were 89.2% and 90.4% , respectively, with no significant difference (P>0.05). The rate of femoral head osteonecrosis in the orthosis combined with walker group was significantly lower than that in the improved hip frog cast fixation group (1.5 % vs. 5.3 % , P<0.05) , but the re-dislocation rate in the former was significantly higher than that in the latter (6.9 % vs. 1.1% , P<0.05). Conclusion Both methods are effective for DDH. Orthosis combined with walker has a lower propor-tion of femoral head osteonecrosis, but a higher proportion of re-dislocation.

9.
Journal of Central South University(Medical Sciences) ; (12): 811-814, 2009.
Article in Chinese | WPRIM | ID: wpr-814266

ABSTRACT

OBJECTIVE@#To measure the anatomic data of the proximal femur and to design an internal fixation instrument aiming at subtrochanteric fracture.@*METHODS@#We measured the anatomic data of 56 pairs of the matching proximal femur specimens: the diameter of femoral head (HD), the axis length of femoral head (HAL), 135 degree femoral head-neck axis length (HNAL), 135 degree femoral head-neck axis upper length (HNAUL), 135 degree femoral head-neck axis underside length (HNADL), the anterior-posterior axis diameter of femoral neck (NAPD), the upper-underside diameter of femoral neck (NUUD), femoral neck-shaft angle (NFA), femoral shaft lateral cortex-greater trochanter angle (SLGA), the medial-lateral diameter of lesser trochanter level's femoral shaft (LSMLD), the anterior-posterior diameter of lesser trochanter level's femoral shaft (LSAPD), the medial-lateral diameter of 5 cm below lesser trochanter femoral shaft (5 cm MLD), and the anterior-posterior diameter of 5 cm below lesser trochanter femoral shaft (5 cm APD). Part of the data was analyzed and compared.@*RESULTS@#HD was (46.69+/-3.73) mm, HAL was (39.22+/-4.17) mm, HNAL was (95.45+/-8.16) mm, HNAUL was (84.02+/-7.11) mm, HNADL was (99.95+/-9.34) mm, NAPD was (26.27+/-3.15) mm, NUUD was (32.24+/-3.31) mm, NFA was 126.21 degree+/-7.13 degree, SLGA was 16.38 degree+/-4.04 degree, LSMLD was (31.05+/-3.57) mm, LSAPD was (27.63+/-2.96) mm, 5 cm MLD was (26.36+/-3.22) mm, and 5 cm APD was (25.59+/-2.75) mm. NFA was positively correlated with SLGA (r=0.396, P=0.003).@*CONCLUSION@#It is necessary to design internal fixator to fit the anatomical feature of Chinese femur for the treatment of subtrochanteric fracture, and we should thoroughly consider the angle of the SLGA.


Subject(s)
Humans , Anthropometry , Cadaver , Equipment Design , Femur Head , Femur Neck , Fracture Fixation, Internal , Hip Fractures , General Surgery
SELECTION OF CITATIONS
SEARCH DETAIL