Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Acta Academiae Medicinae Sinicae ; (6): 21-27, 2017.
Article in English | WPRIM | ID: wpr-277904

ABSTRACT

Objective To prospectively investigate the radiation dose and image quality of pediatric chest CT using Sn100 kV on a third-generation dual-source CT (DSCT)in comparison to standard 100 kV chest CT. Methods From December 12,2015 to June 30,2016,45 consecutive pediatric patients referred for non-contrast chest CT scan in Peking Union Medical College Hospital were prospectively enrolled as study group. They were examined at 100 kV with a dedicated tin filter on a third-generation DSCT. These patients were retrospectively matched with 45 patients who were examined on a second-generation DSCT at 100 kV without tin filter. The radiation dose as well as the lung and mediastinal window image quality(IQ)of the two groups were compared and analyzed statistically. IQ was evaluated using a five-point scale (1=unevaluable,5=excellent). Differences of radiation dose and noise between the two groups were determined with variance analysis and t test,IQ with Mann-Whitney U test,and the consistency of diagnosis with Kappa test. Results The average CT dose index volume of the study group was (0.24±0.11)mGy,which was decreased by 92% compared with the control group [(3.10+1.18)mGy] (t=16.287,P=0.000). Mean dose-length product and mean effective dose for study group were significantly lower than those of control group [(7.13±4.72)mGy·cm vs. (84.78±46.78)mGy·cm,t=11.077,P=0.000;(0.11±0.06)mSv vs.(1.23±0.61)mSv,t=12.334,P=0.000]. There was no significant difference between the two groups in terms of image noise (t=-0.003,P=0.397)and contrast to noise ratio (t=0.545,P=0.488). There was no significant difference between the two groups in lung window IQ (doctor 1:U=796.000,P=0.055;doctor 2:U=889.500,P=0.277),while significant difference was seen concerning of the mediastinal window IQ (doctor 1:U=305.000,P=0.000;doctor 2:U=276.500,P=0.000). Referring to the lung window,the median IQ for the study group and control group was 4 (3-5)and 4 (3-5),respectively. All imaging findings had acceptable IQ. The breath motion artifacts (χ=13.846,P=0.001)and heart beat artifacts (χ=53.519,P=0.000)of the study group were significantly lower than those of the control group. Conclusion Compared with standard 100 kV chest CT,the use of tin-filtered Sn100 kV on a third-generation DSCT provided 92% dose reduction in pediatric chest CT examinations while maintaining diagnostically acceptable lung window images.


Subject(s)
Child , Humans , Artifacts , Feasibility Studies , Lung , Diagnostic Imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Thorax , Diagnostic Imaging , Tomography, X-Ray Computed , Methods
2.
Acta Academiae Medicinae Sinicae ; (6): 95-100, 2017.
Article in English | WPRIM | ID: wpr-277893

ABSTRACT

Objective To explore the feasibility of reducing radiation dose of CT colonography (CTC) while preserving image quality using the third-generation dual-source CT at 70 kV tube voltage with advanced modeled iterative reconstruction (ADMIRE). Methods This prospective study consecutively included 53 patients. All patients underwent CTC at 120 kV in supine position with filtered back projection reconstruction and at 70 kV in prone position with ADMIRE with the same scan range. Radiation dose and image quality were compared between these two protocols. Results CT dose index volume,dose-length product,and effective dose of 70 kV were (1.47±0.23)mGy,(68.85±13.82)mGy·cm,and (1.03±0.21)mSv,respectively,which were significantly lower than 120 kV mode [(2.96±0.61)mGy (t=25.356,P=0.000),(136.97±32.77)mGy·cm (t=22.246,P=0.000),and (2.05±0.49)mSv (t=22.293,P=0.000)]. Signal to noise ratio of 70 kV with ADMIRE was 3.60±0.58,which was obviously higher than that of 120 kV as 2.34±0.47 (t=-18.036,P=0.000). Noise of 70 kV with ADMIRE was (11.81±1.93)HU,which was obviously lower than that of 120 kV as (14.39±2.57)HU (t=7.856,P=0.000). The κ value of two radiologists' overall subjective image score was 0.843 (P=0.000). For 2D images,the noise score of 70 kV with ADMIRE was significantly lower (Z=325.000,P=0.000) and the overall image quality was significantly higher (Z=78.000,P=0.001) compared with 120 kV;however,the sharpness had no significant difference. All scores ranged from 4 to 5. For 3D virtual endoscopy,the overall image quality of 70 kV with ADMIRE and 120 kV was not significantly different (Z=4.000,P=0.059),and all scores ranged from 4 to 5. Conclusion CTC at 70 kV tube voltage combined with ADMIRE can remarkably reduce the radiation dose while maintaining imaging quality than 120 kV at third-generation dual-source CT.


Subject(s)
Humans , Colon , Diagnostic Imaging , Colonography, Computed Tomographic , Methods , Prone Position , Prospective Studies , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Radionuclide Imaging , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL