Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedic Trauma ; (12): 19-24, 2023.
Article in Chinese | WPRIM | ID: wpr-992675

ABSTRACT

Objective:To analyze the clinical efficacy of treatment of cement dislodgement after vertebral augmentation for osteoporotic vertebral fractures.Methods:A retrospective study was conducted to analyze the data of 13 patients who had been treated at Department of Orthopaedics, The First Affiliated Hospital of Soochow University for cement dislodgement after vertebral augmentation for osteoporotic vertebral fractures from July 2013 to July 2022. There were 4 males and 9 females, with an average age of (76.5±8.6) years and a T value of bone mineral density of -3.3±0.6. By the CT and MRI features of cement dislodgement, their conditions fell in 4 types: cement loosening in situ (4 cases), anterior cement moving (6 cases), anterior cement moving with posterior bone mass moving (2 cases), and posterior cement moving (1 case). They were treated by percutaneous vertebroplasty (3 cases), pedicle screw fixation combined with bone graft fusion and decompression (7 cases), and conservative therapy (3 cases). The curative effects for surgical patients were evaluated by comparing their visual analogue scale (VAS), Oswestry dysfunction index (ODI) and cobb angle of kyphosis at preoperation, 1 week and 1 month postoperation, and the last follow-up, and Frankel grading for nerve injury as well. The curative effects for patients undergoing conservative treatment were evaluated by observing their symptoms.Results:This cohort was followed up for 7 (5, 12) months after treatment. The VAS scores [5.0 (4.0, 5.0) points, 3.0 (2.0, 3.0) points, and 3.0 (2.0, 3.0) points] in the 10 surgical patients at 1 week and 1 month postoperation and the last follow-up were significantly improved compared with the preoperative value [8.5 (8.0, 9.0) points] ( P<0.05); the VAS scores at 1 month postoperation and the last follow-up were also significantly improved compared with that at 1 week postoperation ( P < 0.05), but there was no significant difference between the last follow-up and 1 month postoperation ( P > 0.05). The ODIs (50.6%±4.2%, 37.8%±4.5%, and 29.3%±5.6%) in the 10 surgical patients at 1 week and 1 month postoperation and the last follow-up were significantly improved compared with the preoperative value (93.2%±3.6%), showing significant differences in pairwise comparisons ( P<0.05). The cobb angles [10.0 (9.0, 11.0)°, 9.0 (9.0, 11.0)°, and 10.0 (9.0, 12.0)°] in the 10 surgical patients at 1 week and 1 month postoperation and the last follow-up were significantly improved compared with the preoperative value [12.5 (11.0, 14.0)°] ( P<0.05) , but there was no statistically significant difference between the time points after operation ( P>0.05). The Frankel grading was significantly improved in the 6 patients with nerve injury after operation. Of the 3 patients undergoing conservative treatment, the symptoms were cured in one, showed no change during follow-up in one, and aggravated in one. Conclusion:Surgical treatment can significantly relieve pain, improve spinal dysfunction and repair nerve injury in patients with bone cement dislodgement after vertebral augmentation.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 839-847, 2022.
Article in Chinese | WPRIM | ID: wpr-956596

ABSTRACT

Objective:To compare the clinical efficacy between 3D printing-assisted percutaneous balloon dilatation calcaneal plasty (3D-PCP) and conventional open reduction and internal fixation (ORIF) via the extended lateral L-shaped approach in the treatment of osteoporotic calcaneal fractures of Sanders type Ⅱ or Ⅲ in the elderly patients.Methods:Retrospectively analyzed were the data of 36 elderly patients with osteoporotic calcaneal fracture of Sanders type Ⅱ or Ⅲ who had been surgically treated at Department of Orthopaedics, Yixing People's Hospital from June 2012 to June 2018. According to their treatment methods, the patients were divided into a 3D-PCP group [16 cases, 9 males and 7 females with an age of (73.0 ± 3.4) years] and an ORIF group [20 cases, 8 females and 12 females with an age of (71.4 ± 2.6) years]. The 2 groups were compared in terms of hospital stay, operation time, intraoperative fluoroscopy frequency, suture removal time, weight bearing time, fracture healing time, visual analogue scale (VAS) for the surgical site 2 days and one year after surgery, American Foot and Ankle Surgery Association (AOFAS) ankle-hindfoot score, calcaneal imaging parameters (B?hler angle, Gissane angle, and length, width and height of the calcaneus axis) at 2 days and one year after surgery, and postoperative complications.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P > 0.05). All patients were followed up for 14 to 18 months (mean, 15.6 months). Compared with the ORIF group, the 3D-PCP group had significantly shorter hospital stay, significantly shorter operation time, significantly earlier suture removal, significantly earlier weight-bearing, significantly lower VAS scores at 2 days after surgery, significantly higher AOFAS ankle-hindfoot scores at one month after surgery, but significantly more times of intraoperative fluoroscopy (all P < 0.05). In all patients, the VAS scores at 2 days after surgery were significantly lower than those before surgery, and those at one year after surgery significantly lower than those at 2 days after surgery ( P < 0.05). In all patients, the AOFAS ankle-hindfoot scores at one month after surgery were significantly higher than those before surgery ( P < 0.001). In the ORIF group, the AOFAS ankle-hindfoot scores at one year after surgery were significantly higher than those at one month after surgery ( P < 0.05), but in the 3D-PCP group there was no such a significant difference between one year and one month after surgery ( P > 0.05). There was no significant difference in VAS score, AOFAS score, fracture healing time or postoperative imaging parameters between the 2 groups at one year after surgery ( P > 0.05). There was no significant difference either in the incidence of complications between the 2 groups ( P > 0.05). Conclusion:In the treatment of osteoporotic calcaneal fractures of Sanders type Ⅱ or Ⅲ in the elderly patients, compared with conventional ORIF, 3D-PCP shows advantages of shorter operation time, minimal invasion, quicker incision healing, shorter hospital stay, earlier weight-bearing exercise, and better functional recovery but a disadvantage of increased times of intraoperative fluoroscopy.

3.
Chinese Journal of Surgery ; (12): 425-430, 2014.
Article in Chinese | WPRIM | ID: wpr-314688

ABSTRACT

<p><b>OBJECTIVE</b>To study clinical outcomes following anterior cervical discectomy and fusion (ACDF) using ROI-C compared to traditional cage with anterior plating in treating the cervical spondylotic myelopathy.</p><p><b>METHODS</b>A total of 66 patients with the cervical spondylotic myelopathy were treated with ACDF between April 2011 and October 2012. Twenty-three patients underwent ACDF using the ROI-C device were classified as the ROI-C group and 43 patients received traditional cage with anterior plating served as the titanium plate group. Related indicators, such as operation time, intraoperative blood loss, intraoperative fluoroscopy times, incidence of postoperative dysphagia and ratio of bone graft fusion were recorded and compared between two groups. The clinical outcomes were evaluated by Japanese Orthopaedic Association (JOA) scores and visual analog scale (VAS) scores. The pre- and postoperative results were compared with a paired sample t-test. The results between groups were compared utilizing the grouped t-test or χ² test.</p><p><b>RESULTS</b>All cases were followed up. The follow-up period was 12 to 38 months and 14 to 39 months in ROI-C group and titanium plate group respectively. For the age, gender, the JOA scores, VAS scores of neck pain and arm pain during preoperative, the surgical level constituent ratio and the follow-up time, there were no significant differences between two groups. In ROI-C group, the operation time was (123 ± 38) minutes, intraoperative blood loss was (84 ± 37)ml, exposure times to the X-ray C-arm machine was (3.5 ± 0.7) times, which were all significantly lower than titanium plate group ((165 ± 60) minutes, (128 ± 66) ml, (5.9 ± 1.2) times respectively, t = -3.27, -3.25, - 9.45, P = 0.02, 0.02, 0.00). The mean JOA scores increased significantly from pre-surgery to 1 month postoperatively, 3 months postoperatively, and last follow-up in ROI-C group (t = 11.94, 11.32, 10.60, all P = 0.00) and titanium plate group(t = 15.07, 19.51, 17.55, all P = 0.00). The mean VAS scores of neck pain and arm pain decreased significantly from pre-surgery to 1 month postoperatively, 3 months postoperatively, and last follow-up in ROI-C group (t = -16.64-- 9.68, all P = 0.00) and titanium group(t = -16.56--12.38, all P = 0.00). There was no significant difference on JOA scores and VAS scores of neck pain and arm pain between the two groups at the same time (P > 0.05). However, significant difference was observed in incidence of postoperative dysphagia (χ² = 6.79, P = 0.01). In addition, bony fusion was obtained in all cases at the last follow-up postoperatively. There was no significant difference on ratio of bone graft fusion between two groups.</p><p><b>CONCLUSION</b>The ROI-C leads to similar clinical outcomes compared to traditional cage combined with anterior plating for the treatment of the cervical spondylotic myelopathy, while the ROI-C carries a simpler operation, shorter operation time, less intraoperative blood loss, less exposure times to the X-ray and a lower risk of postoperative dysphagia.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Bone Plates , Cervical Vertebrae , General Surgery , Diskectomy , Methods , Follow-Up Studies , Spinal Fusion , Methods , Titanium , Treatment Outcome
4.
Chinese Journal of Trauma ; (12): 692-695, 2008.
Article in Chinese | WPRIM | ID: wpr-398523

ABSTRACT

Objective To compare the value of "linear shadow" of posterior vertebral body wall under standard lateral X-ray fluoroscopy and CT scan in evaluating the reduction of bone fragment retro-pulsed into the spinal canal so as to provide evidence for indirect reduction degree of bone fragment under X-ray fluoroscopy during operation. Methods A retrospective study was done on 25 cases of thoraco-lumbar burst fractures treated at our department. There were 15 males and 10 females, at age range of 24-66 yeas(average 44. 9 years). Preoperative CT scan confirmed burst fractures in all cases. Bone frag-ment occupied mearl 35. 2% of midsngittal diameter of injured segment. All cases were treated by indirect reduction with short-sesment pedicle instrumentation, rather than laminotomy or partial laminectomies. When imging of posterior vertebral body wall manifested a continuous and smooth"linear shadow" under standard lateral X-ray fluoroscopy during operation, bone fragment War considered to be under reduction. CT span was performed to evaluate the reduction of bone fragment postoperatively. Results The bone fragment occupation of midsngittal diameter of injured segment was decreased from preoperative 35. 2%to postoperative 8. 6%, with statistical difference(t=9. 122, P<0. 01). Neurological function of all 25 cases was normal at last follow-up. The decompression of spinal canal was effective. Conclusions A continuous and smooth"linear shadow"on posterior vertebral body wall imaging is a simple and effective way to judge the reduction of bone fragment retropulsed into the spinal canal and can provide evidence for whether laminotomies and pushing bone fragment are necessary during operation.

5.
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-545572

ABSTRACT

[Objective]To evaluate the outcome of thoracolumbar fracture with spinal cord injury treated with short-segment pedicle instrumentation.[Method]47 cases of thoracolumbar fracture with spinal cord injury from 1999 to 2004 in our department were collected,all of them were treated with short-segment pedicle instrumentation.The radiologic,neurologic,and functional outcome were assessed.[Result]All of the 47 cases were followed up,the mean follow-up were 51.9 months(18~ 86 months),the average of vertebral anterior and posterior height were corrected from 43.6%,71.4% to 92.2%,96.4%;and 88.3%,93.1% at the last follow-up separately.The Cobb's angle were corrected from 23.5?to 4.3?,and 8.8? at the last follow-up.62.8% of the vertebral canal was occupied pre-operation,and 11.4% post-operation,6.2% at last follow-up.There was significant deference in targets between pre-operation and post-operation(P0.05).Neurologic status improved at least 1 Frankel grade in the patients who had preoperative incomplete paraplegia.61.7% of patients returned to work.[Conclusion]Short-segment pedicle instrumentation can provide good reduction,strong fixation,complete decompression and fusion.The treatment outcome is good.Moreover,it is a less traumatic,simple and safe technique.

SELECTION OF CITATIONS
SEARCH DETAIL