Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Microsurgery ; (6): 95-100, 2023.
Article in Chinese | WPRIM | ID: wpr-995482

ABSTRACT

Objective:To explore the effect of sciatic nerve derived exosomes(SN-EXO) on axon regeneration and functional recovery after peripheral nerve injury(PNI).Methods:From March 2021 to October 2022, the Department of Orthopedics of the First Affiliated Hospital of Zhengzhou University studied the effect of SN-EXO on the proliferation of Schwann cells(SCs) through EdU cell proliferation experiment. Twenty-one healthy male SD rats were randomly divided into 3 groups of sham operation, peripheral nerve injury(PNI) and SN-EXO treatment, with 7 rats in each group. The right sciatic nerves of rat models in sham group were exposed without injury. In the rat in PNI group and SN-EXO treatment group, PBS and SN-EXO were injected under the epineurium of right sciatic nerves following sciatic nerve crush. Sciatic nerve function index(SFI) was performed at 28 days after operation, and then sacrificed. Right sciatic nerves were removed for further exploration of nerve regeneration. The histopathological changes and axon arrangement of sciatic nerves were evaluated by HE staining. Regeneration efficiency of neurofilaments and SCs were obserred by NF200 and S100β double staining of sciatic nerve. The data obtained were statistically analyzed, and P<0.05 was statistically significant. Results:It was found that SN-EXO can significantly enhance the proliferation ability of SCs, with statistically significant difference( P<0.05). SFI in SN-EXO treatment group and PNI group were(-27.65±4.36) and(-57.33±7.49), respectively, and the difference was statistically significant( P<0.05). Axons in SN-EXO treatment group were arranged more closely and orderly than those in the PNI group at 28 days after operation, and there were less injury induced axon disintegration and vacuolation. Immunofluorescence assay indicated that NF200 and S100β fluorescence intensity in SN-EXO treatment group was significantly higher than that in the PNI group, and the difference was statistically significant( P<0.05). Conclusion:SN-EXO could enhance the proliferation of SCs to promote axon regeneration following peripheral nerve injury.

2.
International Journal of Cerebrovascular Diseases ; (12): 494-499, 2022.
Article in Chinese | WPRIM | ID: wpr-954160

ABSTRACT

Objective:To investigate the emergency surgical effect of ruptured intracranial dural arteriovenous fistula (DAVF).Methods:Patients with ruptured intracranial DAVF underwent microsurgery in the Department of Neurosurgery, Nanping First Hospital Affiliated to Fujian Medical University from May 2013 to July 2022 were retrospectively included. The clinical, imaging and follow-up data were collected, and the clinical characteristics, selection of surgical methods and treatment effects of patients were summarized.Results:A total of 8 patients with DAVF were enrolled. Their age ranged from 11 to 60 years (average, 48 years). There were 7 males and 1 female. All 8 patients suffered from intracranial hemorrhage, manifested as headache and vomiting in 2 cases, simple conscious disturbance in 2 cases, conscious disturbance with cerebral hernia in 3 cases, and conscious disturbance with limb paralysis in 1 case. The fistula was located in the anterior fossa in 4 cases (including 2 cases with aneurysms), the middle fossa in 2 cases (including 1 case with moyamoya disease), the transverse sinus in 1 case, and the anterior 1/3 area of the sagittal sinus in 1 case. Cognard classification: 7 patients were type Ⅲ and 1 was type Ⅳ. After admission, all patients underwent emergency craniotomy and microsurgery to remove hematoma. Among them, 4 patients underwent decompressive craniectomy at the same time, 1 patient with moyamoya disease underwent dural turnover and temporalis muscle application at the same time, and 2 patients with aneurysms at the same location were clipped at the same time. Postoperative re-examination of head CT showed that the hematoma was cleared satisfactorily and the midline was no shift in all 8 patients. CT angiography (CTA) showed that the fistula disappeared within 2 weeks. Seven patients were followed up within 1-12 months after operation. CTA or digital subtraction angiography showed no recurrence of DAVF. Two patients with aneurysms did not have residual or recurrent aneurysms. All patients had no new neurological symptoms, and the Glasgow Outcome Scale score in 2 patients increased by 1 compared with that at discharge.Conclusion:Emergency microsurgery is an effective method for the treatment of ruptured intracranial DAVF, especially for patients with special parts or complicated hematoma, cerebral hernia, and other vascular diseases.

3.
Chinese Journal of Postgraduates of Medicine ; (36): 704-707, 2016.
Article in Chinese | WPRIM | ID: wpr-495462

ABSTRACT

Objective To explore the microsurgery methods in patients with early intracranial aneurysm rupture. Methods Sixty-seven patients with early intracranial aneurysm rupture received the emergency microsurgery after releasing cerebrospinal fluid from improved Paine point via pterion craniotomy. Thirty-nine patients received surgery within 1 d after intracranial aneurysm rupture, and the other 28 patients were within 1-3 d. Results The therapeutic effect was evaluated by Glasgow outcome score (GOS) at discharge. Among the 45 patients with Hunt-Hess Ⅰ-Ⅲ grade, cure was in 41 cases, improved in 4 cases. Among the 22 patients with Hunt-HessⅣ-Ⅴgrade, cure was in 6 cases, improved in 6 cases, moderate disability in 4 cases, severe disability in 1 case, and death was in 5 cases. Conclusions The microsurgery of clipping aneurysm directly via pterion approach is still by far the most reliable treatment. And releasing cerebrospinal fluid from improved Paine points can effectively reduce the acute brain swelling of early operation, which will make it an effective adjuvant therapy to emergency microsurgery of clipping aneurysm.

4.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 317-320, 2014.
Article in Chinese | WPRIM | ID: wpr-306308

ABSTRACT

<p><b>OBJECTIVE</b>To improve the occupational health management levels in electroplating enterprises with quantitative classification measures and to provide a scientific basis for the prevention and control of occupational hazards in electroplating enterprises and the protection of workers' health.</p><p><b>METHODS</b>A quantitative classification table was created for the occupational health management in electroplating enterprises. The evaluation indicators included 6 items and 27 sub-items, with a total score of 100 points. Forty electroplating enterprises were selected and scored according to the quantitative classification table. These electroplating enterprises were classified into grades A, B, and C based on the scores.</p><p><b>RESULTS</b>Among 40 electroplating enterprises, 11 (27.5%) had scores of >85 points (grade A), 23 (57.5%) had scores of 60∼85 points (grade B), and 6 (15.0%) had scores of <60 points (grade C).</p><p><b>CONCLUSION</b>Quantitative classification management for electroplating enterprises is a valuable attempt, which is helpful for the supervision and management by the health department and provides an effective method for the self-management of enterprises.</p>


Subject(s)
Humans , Electroplating , Occupational Exposure , Occupational Health
5.
Acta Anatomica Sinica ; (6)1955.
Article in Chinese | WPRIM | ID: wpr-680658

ABSTRACT

Annulate lamellae (AL) in oocytes of eel, Anguilla japonica have been observed with electron microscopy. Two types of AL have been found in the cytoplasm of these cells, one of which is the common type, characterized by a stack of parallelly arranged lamellae with annuli (or rings) as shown in figure 1, another is a rare one, which appears as alternative arrangement of parellel lamellae with annuli and membrane-like structures as shown in figures 2~4. The only difference between them is the presence of membrane-like structure in the latter. The origin and function of the membrane-like structure have not been found out yet. It is suggested that this structure might be similar to above-mentioned lamellae in origin and might be a "buffer" in function.

SELECTION OF CITATIONS
SEARCH DETAIL