Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Archives of Otolaryngology-Head and Neck Surgery ; (12): 83-85, 2018.
Article in Chinese | WPRIM | ID: wpr-692212

ABSTRACT

OBJECTIVE To compare the difference of octave band CE-Chirp ABR response threshold and behavioral auditory thresholds in children with hearing loss, and to explore the clinical value of octave band CE-Chirp ABR. METHODS Twenty-one children (40 ears) with hearing loss were selected. The octave band CE-Chirp ABR response threshold and behavioral auditory hearing threshold were measured in quiet environment. The results of two different test methods were compared. RESULTS The frequencies of octave band CE-Chirp ABR response thresholds and behavioral auditory thresholds were statistically analyzed. The correlation coefficients at different frequencies were 0.693, 0.830, 0.836 and 0.845, respectively, and the P values were <0.05. CONCLUSION There is good correlation between octave band CE-Chirp ABR response and behavioral auditory hearing measurement. Octave band CE-Chirp ABR, as an objective audiometry technique, has good stability and reliability for the objective response of hearing loss, and can better reflect the hearing level.

SELECTION OF CITATIONS
SEARCH DETAIL