1.
Journal of the Korean Gastric Cancer Association ; : 88-95, 2009.
Article in Korean | WPRIM | ID: wpr-162528

ABSTRACT

PURPOSE: p53 and bcl-2 are important markers of apoptosis. The expression of p53 and bcl-2 in gastric adenocarcinoma was examined in relation to prognosis and survival rate. MATERIALS AND METHODS: The clinicopathologic data from 238 patients who underwent gastrectomies for gastric adenocarcinoma between December 1999 and July 2007 were reviewed. Immunohistochemical staining of gastric adenocarcinoma tissues embedded in paraffin blocks was performed using an Envision kit (DAKO, Glostrup, Denmark). Statistical comparisons were made between age, gender, tumor invasion, lymph node metastasis, TNM stage, Lauren's classification, cell differentiation, and the relationship with p53 and bcl-2. RESULTS: The expression of p53 was related to cell differentiation (P=0.028) and UICC TNM stage (P<0.001). The expression of bcl-2 was related to UICC TNM stage (P=0.005). The co-expression of p53 and bcl-2 was related to UICC TNM stage (P=0.002). The co-expression group exhibited a greater reduction in the survival rate (P=0.001). CONCLUSION: The expression of p53 and bcl-2 nuclear proteins has significant relationships with other conventional prognostic factors and the survival rate. Bcl-2 will be characterized through analysis of a greater number of patients and comparison with survival data over a longer period of time.


Subject(s)
Humans , Adenocarcinoma , Apoptosis , Cell Differentiation , Gastrectomy , Lymph Nodes , Neoplasm Metastasis , Nuclear Proteins , Paraffin , Prognosis , Survival Rate
2.
Korean Journal of Oral and Maxillofacial Radiology ; : 165-170, 2007.
Article in Korean | WPRIM | ID: wpr-42620

ABSTRACT

PURPOSE: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. MATERIALS AND METHODS: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR 9000NTM Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. RESULTS: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range -0.49 ~+0.63 mm at PSR900N and -0.97~+1.14 mm at i-CAT(P.0.05). It was possible to identify and measure PSR 9000NTM Dental CT system to the limit 0.48+/-0.06 mm (P.0.05) and i-CAT CBCT to the limit 0.86+/-0.09 mm (P.0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. CONCLUSIONS: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.


Subject(s)
Bicuspid , Cone-Beam Computed Tomography , Dental Pulp Cavity , Incisor , Molar , Radiography, Dental , Tomography, X-Ray Computed , Tooth