Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
The Korean Journal of Critical Care Medicine ; : 42-46, 2009.
Article in Korean | WPRIM | ID: wpr-650247

ABSTRACT

Topical epinephrine is useful to reduce bleeding during skin grafting. However, even though a clear operative field is obtained, systemic absorption of topical epinephrine can occur and this may cause severe hypertension, arrhythmias, ventricular tachycardia, myocardial ischemia, pulmonary edema, or cardiac arrest. We managed a case of cardiac arrhythmia during general anesthesia, which was induced by gauze soaked in topical epinephrine used for skin grafting of burn wounds. A 26-year-old woman developed premature ventricular complexes and ventricular tachycardia during surgery when epinephrine-soaked gauze was applied to the skin donor and burn wound sites to control oozing. The patient was resuscitated immediately and within 10 minutes the vital signs had normalized. It is recommended that caution is exercised when epinephrine-soaked gauze is applied to a large area of skin.


Subject(s)
Adult , Female , Humans , Absorption , Anesthesia, General , Arrhythmias, Cardiac , Burns , Epinephrine , Heart Arrest , Hemorrhage , Hypertension , Myocardial Ischemia , Pulmonary Edema , Skin , Skin Transplantation , Tachycardia, Ventricular , Tissue Donors , Ventricular Premature Complexes , Vital Signs
2.
Korean Circulation Journal ; : 146-154, 2002.
Article in Korean | WPRIM | ID: wpr-202285

ABSTRACT

BACKGROUND AND OBJECTIVES: The diagnosis of paroxysmal atrial fibrillation (PAF) and the prediction of its recurrence are sometimes difficult. There have been several recent studies attempting to detect patients at risk for PAF while in sinus rhythm by using the P wave signal-averaged ECG. We undertook to define an appropriate technique of P wave signal-averaged ECG and to estimate the reproducibility of the test. Additionally, we estimated the usefulness of P wave signal-averaged ECG in patients at risk for PAF. SUBJECTS AND METHODS: Forty-five patients with PAF were included in the study undertaken between March 1997 and June 1998. Twelve-lead surface ECG and P wave signal-averaged ECG were performed in the patients. The total P wave duration was measured by the P wave signal-averaged ECG using P wave template and least-square fit filter. The same process was followed in forty sex- and age-matched controls. RESULTS: The measurement of P wave duration with P wave signal-averaged ECG was highly reproducible. The measured P wave duration showed significant prolongation in the patient group at cutoff frequencies of 20 Hz and 30 Hz (123.6+/-15.3 vs. 114.8+/-14.5 msec, p=0.009 at 20 Hz, 120.1+/-17.8 vs. 107.5+/-18.8 msec, p=0.002 at 30 Hz). An abnormal P wave duration defined as over 120 msec in duration by P wave signal-averaged ECG was able to detect PAF with a sensitivity of 60%, specificity of 73%, positive predictive value of 71%, and a negative predictive value of 62%. CONCLUSION: A prolonged P wave duration as measured by P wave signal-averaging technique may be a simple noninvasive marker of risk for the development of atrial fibrillation.


Subject(s)
Humans , Atrial Fibrillation , Diagnosis , Electrocardiography , Recurrence , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL