Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
World Journal of Emergency Medicine ; (4): 33-36, 2020.
Article in English | WPRIM | ID: wpr-782361

ABSTRACT

BACKGROUND@#MAVERIC (Mitral Valve Repair Clinical Trial) validates the safety and efficacy of the ARTO system. We here report the first two successful cases of utilizing the ARTO system in patients with symptomatic heart failure (HF) with functional mitral regurgitation (FMR) in Asia.@*METHODS@#Two patients, aged 70 and 63, had severe HF with FMR. Transesophageal echocardiography confirmed that the left ventricular ejection fractions were less than 50% with severe mitral regurgitation (MR) in both patients. Optimizing drug treatment could not mitigate their symptoms. Therefore, we used the ARTO system to repair the mitral valve for these patients on March 5 and 6, 2019, respectively.@*RESULTS@#Mitral valve repairs using the ARTO system were successfully performed under general anaesthesia for these two patients. MR was decreased immediately after the procedures in both patients. The 30-day and 3-month transthoracic echocardiography (TTE) revealed a moderate to severe MR in both patients, and the New York Heart Association (NYHA) scales were also partially improved.@*CONCLUSION@#The first two cases in Asia indicate that the ARTO system is feasible for patients with heart failure with FMR, and the patient selection appears to be crucial.

2.
World Journal of Emergency Medicine ; (4): 197-204, 2019.
Article in English | WPRIM | ID: wpr-782530

ABSTRACT

BACKGROUND@#Current data is lacking about the progression of ascending aortic dilatation after transcatheter aortic valve replacement (TAVR) in aortic stenosis (AS) patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). This study aims to assess the ascending aortic dilatation rate (mm/ year) after TAVR in patients with BAV versus TAV using a multidetector computed tomography (MDCT) follow-up and to determine the predictors of ascending aortic dilatation rate.@*METHODS@#Severe AS patients undergoing TAVR from March 2013 to March 2018 at our center with MDCT follow-ups were included. BAV and TAV were identified using baseline MDCT. Baseline and follow-up MDCT images were analyzed, and the diameters of ascending aorta were measured. Study end point is ascending aortic dilatation rate (mm/year). Furthermore, factors predicting ascending aortic dilatation rate were also investigated.@*RESULTS@#Two hundred and eight patients were included, comprised of 86 BAV and 122 TAV patients. Five, 4, 3, 2, and 1-year MDCT follow-ups were achieved in 7, 9, 30, 46, and 116 patients. The ascending aortic diameter was significantly increased after TAVR in both BAV group (43.7±4.4 mm vs. 44.0±4.5 mm; P<0.001) and TAV group (39.1±4.8 mm vs. 39.7±5.1 mm; P<0.001). However, no difference of ascending aortic dilatation rate was found between BAV and TAV group (0.2±0.8 mm/year vs. 0.3±0.8 mm/year, P=0.592). Multivariate linear regression revealed paravalvular leakage (PVL) grade was independently associated with ascending aortic dilatation rate in the whole population and BAV group, but not TAV group. No aortic events occurred during follow-ups.@*CONCLUSION@# Ascending aortic size continues to grow after TAVR in BAV patients, but the dilatation rate is mild and comparable to that of TAV patients. PVL grade is associated with ascending aortic dilatation rate in BAV patients post-TAVR.

3.
World Journal of Emergency Medicine ; (4): 133-137, 2019.
Article in English | WPRIM | ID: wpr-787539

ABSTRACT

BACKGROUND@#Transapical off-pump NeoChord procedure is a novel minimally invasive surgical repair of degenerative mitral regurgitation (MR). Here, we report the first four cases of NeoChord procedure in patients with mitral valve prolapse in Chinese mainland.@*METHODS@#Four patients, aged 86, 84, 80 and 60 years, with severe MR due to posterior middle scallop prolapse (P2), underwent transapical off-pump artificial chordae implantation on April 9 and 10, 2019. The procedure was performed by left mini-thoracotomy under general anaesthesia and guided by 2D and 3D dimensional transoesophageal echocardiography (TEE).@*RESULTS@#Mitral valve repair via NeoChord procedure was successfully performed with implantation of 3 artificial chordae in the first patient and 3, 2, and 3 artificial chordae in the following patients, respectively. Intraoperative TEE and pre-discharge transthoracic echocardiography (TTE) showed only mild to moderate MR of these four patients and no postoperative complications were noted. There were no changes of TTE finding between one-month follow-up and pre-discharge.@*CONCLUSION@#The successful NeoChord procedures in four Chinese indicate that the valve repair using the NeoChord system for Chinese population is feasible.

SELECTION OF CITATIONS
SEARCH DETAIL