Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Internal Medicine ; (12): 172-176, 2022.
Article in Chinese | WPRIM | ID: wpr-933443

ABSTRACT

Objective:To explore the clinical phenotype and genotype of a family with hereditary hypofibrinogenemia.Methods:Activated partial thrombin time (APTT), prothrombin time (PT),thrombin time (TT) and thrombelastogram (TEG) were tested in all family members. Fibrinogen activity and antigen were detected by Clauss method and immunoturbidimetric method respectively. All exons and flanking sequences of fibrinogen FGA,FGB,FGG genes were analyzed by PCR, and the products were subjected to Sanger sequencing.Results:The proband represented prolonged PT and TT, low Fg activity and antigen, elevated K value and decreased Angle value in TEG. Other family members reported similar changes including proband′s father,daughter and son, and his elder brother and his niece. Exon 5 c.510_512 of FGG gene in the proband revealed a minor deletion mutation.Conclusion:The novel heterozygous missense mutation of exon 5 c.510_512del (Gln170_Ile171 del ins His) of FGG gene is the molecular mechanism that leads to hereditary hypofibrinogenemia in this family.

2.
Chinese Journal of Clinical Laboratory Science ; (12): 173-176, 2019.
Article in Chinese | WPRIM | ID: wpr-821703

ABSTRACT

Objective@#To compare the indirect immunofluorescence staining effect of urinary podocytes by thinprep liquid-based cytologic test (TCT) with that by the conventional centrifugal smear method, and explore its clinical application value. @*Methods@#The morning urine samples from 50 patients with type 2 diabetic nephropathy and 14 healthy controls were smeared with the TCT and conventional centrifugation method, respectively, and then the indirect immunofluorescence staining were performed to observe the morphology of podocytes. @*Results@#For 64 urine samples, the satisfactory rate of TCT smears (85.94%) was significantly higher than that of conventional smears (50.00%), and the podocyte detection rate of TCT smears (73.47%) was also significantly higher than that of conventional smears (51.02%) (P<0.05). When urinary podocytes of the same patient were positive by both methods, the reading effect of TCT smears was obviously superior to that of conventional smears. @*Conclusion@#The TCT combined with indirect immunofluorescence staining is obviously superior to the conventional centrifugal smear method in the podocyte diagnosis of urine samples.

3.
Chinese Journal of Laboratory Medicine ; (12): 544-547, 2017.
Article in Chinese | WPRIM | ID: wpr-611488

ABSTRACT

Direct oral anticoagulants,include direct thrombin inhibitor and direct factor Xa inhibitor.As the pharmacokinetics and pharmacodynamics of these drugs are known,their plasma concentration is not food-effective,and theoretically it is not necessary to monitor routinely.However, clinical practice in recent years has shown that anticoagulant effect of DOACs is required to evaluate in patients with thrombosis, major bleeding, emergency surgery, hepatic/renal dysfunction and other special situations.Recent studies have shown that routine coagulation assays such as activated partial thromboplastin time(APTT) and thrombin time(TT) can be used as laboratory screening tests for direct thrombin inhibitor dabigatran and prothrombin time(PT) can be used as laboratory screening test for direct factor Xa inhibitor rivaroxaban.DOAC′s quantitative measurements include dilute thrombin time(dTT),hemoclot thrombin inhibitor (HTI),ecarin clotting time (ECT) and ecarin chromogenic assay (ECA) for direct thrombin inhibitor and anti-FXa assay(rivaroxaban calibration) for rivaroxaban.Laboratories should establish their own monitoring range when performing these assays.

4.
Chinese Journal of Laboratory Medicine ; (12): 389-392, 2016.
Article in Chinese | WPRIM | ID: wpr-494292

ABSTRACT

Manual microscopic differential of white blood cell has been challenged by multiparameter flow cytometry,using monoclonal antibodies to define the different leukocyte types.Compared with manual differential,flow cytometry method is more sensitive,specific,objective and has good repeatability.Recent studies demonstrated flow cytometric differential correlates well with manual microscopic method and has good clinical performance for blast and immature granulocyte.Meanwhile more leukocyte populations can be identified with flow cytometric method,such as lymphocyte subset and CD 16 + monocyte,thus helping in monitoring blast in acute leukemia,B lymphocyte proliferative disorder differential diagnosis and minimal residual disease.With the development and improvement of flow cytometric differential,it might be a candidate reference method of leukocyte differential,gradually applied in the routine work.

SELECTION OF CITATIONS
SEARCH DETAIL