Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Article in English | WPRIM | ID: wpr-1044844

ABSTRACT

Objective@#This study aimed to evaluate the safety and efficacy of intranodal lymphangiography and thoracic duct embolization (TDE) for chyle leakage (CL) after thyroid surgery. @*Materials and Methods@#Fourteen patients who underwent intranodal lymphangiography and TDE for CL after thyroid surgery were included in this retrospective study. Among the 14 patients, 13 underwent bilateral total thyroidectomy with neck dissection (central compartment neck dissection [CCND], n = 13; left modified radical neck dissection (MRND), n = 11;bilateral MRND, n = 2), and one patient underwent left hemithyroidectomy with CCND. Ten patients (76.9%) had high-output CL (> 500 mL/d). Before the procedure, surgical intervention was attempted in three patients (thoracic duct ligation, n = 1;lymphatic leakage site ligation, n = 2). Lymphangiographic findings, technical and clinical successes, and complications were analyzed. Technical success was defined as the successful embolization of the thoracic duct after access to the lymphatic duct via the transabdominal route. Clinical success was defined as the resolution of CL or surgical drain removal. @*Results@#On lymphangiography, ethiodized oil leakage near the surgical bed was identified in 12 of 14 patients (85.7%). The technical success rate of TDE was 78.6% (11/14). Transabdominal antegrade access was not feasible due to the inability to visualize the identifiable cisterna chyli or a prominent lumbar lymphatic duct. Among patients who underwent a technically successful TDE, the clinical success rate was 90.1% (10/11). The median time from the procedure to drain removal was 3 days (with a range of 1–13 days) for the 13 patients who underwent surgical drainage. No CL recurrence was observed during the follow-up period (ranging from 2–44 months; median, 8 months). There were no complications, except for one case of chylothorax that developed after TDE. @*Conclusion@#TDE appears to be a safe and effective minimally invasive treatment option for CL after thyroid surgery, with acceptable technical and clinical success rates.

2.
Korean Journal of Radiology ; : 1241-1248, 2023.
Article in English | WPRIM | ID: wpr-1044802

ABSTRACT

Objective@#To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). @*Materials and Methods@#This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. @*Results@#Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%).All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1–36 months. No serious procedure-related adverse events were observed. @*Conclusion@#Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

3.
Ultrasonography ; : 136-146, 2021.
Article in English | WPRIM | ID: wpr-919509

ABSTRACT

Purpose@#This study was aimed to investigate the value of quantitative ultrasound (US) parameters from radiofrequency (RF) data analysis for assessing hepatic steatosis, using controlled attenuation parameter (CAP)-based steatosis grades as the reference standard. @*Methods@#We analyzed 243 participants with both B-mode liver US with RF data acquisition and CAP measurements. On B-mode US images, hepatic steatosis was visually scored (0/1/2/3, none/mild/moderate/severe), and the hepatorenal index (HRI) was calculated. From the RF data analysis, the tissue scatter-distribution imaging parameter (TSI-p) and tissue attenuation imaging parameter (TAI-p) of the liver parenchyma were measured. US parameters were correlated with CAP-based steatosis grades (S0/1/2/3, none/mild/moderate/severe) and their diagnostic performance was evaluated using receiver operating characteristic (ROC) curve analysis. Multivariate linear regression analysis was performed to identify determinants of TSI-p and TAI-p. @*Results@#Participants were classified as having S0 (n=152), S1 (n=54), S2 (n=14), and S3 (n=23) on CAP measurements. TSI-p and TAI-p were significantly correlated with steatosis grades (ρ =0.593 and ρ=-0.617, P<0.001 for both). For predicting ≥S1, ≥S2, and S3, the areas under the ROC curves (AUCs) of TSI-p were 0.827/0.914/0.917; TAI-p, 0.844/0.914/0.909; visual scores, 0.659/0.778/0.794; and HRI, 0.629/0.751/0.759, respectively. TSI-p and TAI-p had significantly higher AUCs than did visual scores or HRI for ≥S1 or ≥S2 (P≤0.003). In the multivariate analysis, the transient elastography-based fibrosis grade (P=0.034) and steatosis grade (P<0.001) were independent determinants of TSI-p, while steatosis grade (P<0.001) was an independent determinant of TAI-p. @*Conclusion@#TSI-p and TAI-p derived from US RF data may be useful for detecting hepatic steatosis and assessing its severity.

SELECTION OF CITATIONS
SEARCH DETAIL