Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
Asian Journal of Andrology ; (6): 719-724, 2023.
Article in English | WPRIM | ID: wpr-1009785

ABSTRACT

Long-segment lichen sclerosus (LS) urethral stricture is a challenge for urologists. Limited data are available for surgeons to make a surgical decision between Kulkarni and Asopa urethroplasty. In this retrospective study, we investigated the outcomes of these two procedures in patients with LS urethral stricture. Between January 2015 and December 2020, 77 patients with LS urethral stricture underwent Kulkarni and Asopa procedures for urethroplasty in the Department of Urology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine (Shanghai, China). Of the 77 patients, 42 (54.5%) underwent the Asopa procedure and 35 (45.5%) underwent the Kulkarni procedure. The overall complication rate was 34.2% in the Kulkarni group and 19.0% in the Asopa group, and no difference was observed ( P = 0.105). Among the complications, no statistical difference was observed in the incidence of urethral stricture recurrence ( P = 0.724) or glans dehiscence ( P = 0.246) except for postoperative meatus stenosis ( P = 0.020). However, the recurrence-free survival rate between the two procedures was significantly different ( P = 0.016). Cox survival analysis showed that antiplatelet/anticoagulant therapy use ( P = 0.020), diabetes ( P = 0.003), current/former smoking ( P = 0.019), coronary heart disease ( P < 0.001), and stricture length ( P = 0.028) may lead to a higher hazard ratio of complications. Even so, these two techniques can still provide acceptable results with their own advantages in the surgical treatment of LS urethral strictures. The surgical alternative should be considered comprehensively according to the patient characteristics and surgeon preferences. Moreover, our results showed that antiplatelet/anticoagulant therapy use, diabetes, coronary heart disease, current/former smoking, and stricture length may be contributing factors of complications. Therefore, patients with LS are advised to undergo early interventions for better therapeutic effects.


Subject(s)
Male , Humans , Urethral Stricture/etiology , Retrospective Studies , Constriction, Pathologic/surgery , Lichen Sclerosus et Atrophicus/surgery , Treatment Outcome , Urologic Surgical Procedures, Male/methods , China , Urethra/surgery , Postoperative Complications/etiology , Mouth Mucosa , Diabetes Mellitus/etiology , Anticoagulants , Coronary Disease
2.
Chinese Journal of Radiation Oncology ; (6): 145-151, 2023.
Article in Chinese | WPRIM | ID: wpr-993165

ABSTRACT

Objective:To develop the real-time radiotherapy monitoring system of three-dimensional (3D) point cloud by using depth camera and verify its feasibility.Methods:Taking the depth camera coordinate system as the world coordinate system, the conversion relationship between the simulation CT coordinate system and the world coordinate system was obtained from the calibration module. The patient's simulation CT point cloud was transformed into the world coordinate system through the above relationship, and registered with the patient's surface point cloud obtained in real-time manner by the depth camera to calculate the six-dimensional (6D) error, and complete the positioning verification and fractional internal position error monitoring in radiotherapy. Mean and standard deviation of 6D calculation error, Hausdorff distance of point cloud after registration and the running time of each part of the program were calculated to verify the feasibility of the system. Fifteen real patients were selected to calculate the 6D error between the system and cone beam CT (CBCT).Results:In the phantom experiment, the errors of the system in the x, y and z axes were (1.292±0.880)mm, (1.963±1.115)mm, (1.496±1.045)mm, respectively, and the errors in the rotation, pitch and roll directions were 0.201°±0.181°, 0.286°±0.326°, 0.181°±0.192°, respectively. For real patients, the translational error of the system was within 2.6 mm, the rotational error was approximately 1°, and the program run at 1-2 frames/s. The precision and speed met the radiotherapy requirement. Conclusion:The 3D point cloud radiotherapy real-time monitoring system based on depth camera can automatically complete the positioning verification before radiotherapy, real-time monitoring of body position during radiotherapy, and provide error visual feedback, which has potential clinical application value.

3.
Chinese Journal of Radiological Health ; (6): 580-585, 2023.
Article in Chinese | WPRIM | ID: wpr-1003568

ABSTRACT

In the current clinical diagnosis, medical images have become an important basis for diagnosis, and different modes of medical images provide different tissue information and functional information. Single-mode images can only provide single diagnostic information, by which difficult and complicated diseases cannot be diagnosed, and comprehensive and accurate diagnostic results can be obtained only with the help of multiple diagnostic information. The multimodal fusion technology fuses multiple modes of medical images into single-mode images, and thus the single-mode images contain complementary information between multiple modes of images, so that sufficient information for clinical diagnosis can be obtained in a single image. In this paper, the multimodal medical image fusion methods are sorted into two types, namely the traditional fusion method and the fusion method based on deep learning.

4.
Asian Journal of Andrology ; (6): 294-298, 2022.
Article in English | WPRIM | ID: wpr-928557

ABSTRACT

General recommendations regarding surgical techniques are not always appropriate for all Peyronie's disease (PD) patients. Therefore, the purpose of this study was to investigate the effects of plication procedures in PD patients with severe penile curvature and the effects of early surgical correction in patients who no longer have progressive deformities. The clinical data from 72 patients who underwent plication procedures were analyzed in this study. Patients were divided into Groups A and B according to the curvature severity (≤60° or >60°) and Groups 1 and 2 according to the duration of disease stabilization (≥3 months or <3 months). At the 1-year follow-up, 90.0% (36/40) and 90.6% (29/32) patients reported complete penile straightening, and 60.0% (24/40) and 100.0% (32/32) patients reported penile shortening in Groups A and B, respectively. No curvature recurrence occurred in any patient, and no significant differences were observed in postoperative International Index of Erectile Function-Erectile Function domain (IIEF-EF), erectile pain, sensitivity, or suture knots on the penis whether such outcomes were grouped according to the curvature severity or the duration of stabilization. However, the duration from symptom onset to surgical management in Group 1 was significantly longer than that in Group 2 (mean ± standard deviation [s.d.]: 20.9 ± 2.0 months and 14.3 ± 1.2 months, respectively, P < 0.001). The present study showed that the plication procedures seemed to be an effective choice for the surgical treatment of PD patients with severe penile curvature. In addition, the early surgical treatment seemed to benefit those patients who already had no erectile pain and no longer exhibited progressive deformity.


Subject(s)
Humans , Male , Erectile Dysfunction/surgery , Patient Satisfaction , Pelvic Pain , Penile Induration/surgery , Penis/surgery , Retrospective Studies , Treatment Outcome
5.
Journal of Forensic Medicine ; (6): 601-605, 2022.
Article in English | WPRIM | ID: wpr-984153

ABSTRACT

OBJECTIVES@#To establish a carbofuran intragastric administration death model in rabbits, and to observe the postmortem distribution and postmortem redistribution of carbofuran-7-phenyl glucuronic acid (Glu-7PH) in rabbits.@*METHODS@#The postmortem distribution: Rabbits were given an administration of 1/2LD50, LD50, 2LD50 carbofuran. Dead rabbits were dissected immediately. Rabbits that had remained alive 2 hours were sacrificed by carbon dioxide (CO2) inhalation and dissected immediately. The myocardium, cardiac blood, liver, spleen, lung, kidney, brain and right hindlimb muscle were collected. The postmortem redistribution: After giving an administration of 4LD50 carbofuran, the myocardium, cardiac blood, liver, spleen, lung, kidney, brain, and right hindlimb muscle were collected at 0, 12, 24, 48, and 72 h postmortem in supine position at 15 ℃ room temperature. The quantity of Glu-7PH was determined by LC-MS/MS.@*RESULTS@#The postmortem distribution: Among the three dose groups, there were significant differences in the quantities of Glu-7PH in different tissues. The postmortem redistribution: There was no significant difference in the Glu-7PH quantities in cardiac blood, mycardium, spleen, kidney, brain and right hindlimb muscle, but there was a significant difference in the Glu-7PH quantities in the liver and lung.@*CONCLUSIONS@#The mycardium, cardiac blood, liver, lung, kidney, brain and hindlimb muscle of rabbits can be used as appropriate samples for Glu-7PH detection. However, it should be noted that Glu-7PH was redistributed postmortem in rabbit liver and lung.


Subject(s)
Animals , Rabbits , Carbofuran , Chromatography, Liquid , Postmortem Changes , Tandem Mass Spectrometry , Autopsy
6.
Chinese Journal of Radiological Health ; (6): 724-730, 2022.
Article in Chinese | WPRIM | ID: wpr-965551

ABSTRACT

@#<b>Objective</b> To investigate the dosimetric effect of truncated regions in computed tomography (CT) images on the targets and organs at risk in volumetric modulated arc therapy (VMAT) for middle thoracic esophageal cancer. <b>Methods</b> CT images of 15 patients with middle thoracic esophageal cancer were selected. Circle masks were used to make the volume of the truncated region account for 10%, 20%, 30%, and 40% of the arm volume, and the corresponding truncated CT images were obtained. The real CT was denoted as CT0. Two radiotherapy plans were made on CT0. One plan was VMAT_1F with full arcs, and the other one was VMAT_3F with arm avoidance. The plans were transplanted to four truncated CT, respectively, and the dosimetric differences between different plans were compared using Wilcoxon signed-rank test. <b>Results</b> Compared with VMAT_1F in CT0, <i>D</i><sub>mean</sub> and <i>V</i><sub>5</sub> of the lung decreased in VMAT_3F, but <i>D</i><sub>max</sub> of the spinal cord, <i>D</i><sub>mean</sub> of the heart, and <i>V</i><sub>20</sub> of the lung increased. In VMAT_3F, there was no statistically significant difference between the dosimetric parameters in the four truncated CT and those in CT0 (all <i>P</i> > 0.05). In VMAT_1F, except for homogeneity index and <i>D</i><sub>max</sub> of the spinal cord, the dosimetric parameters in four truncated CT were significantly different from those in CT0 (<i>P</i> < 0.05). The dosimetric difference increased with the increase in truncated region-to-volume ratio. <b>Conclusion</b> Complete CT data should be collected in clinical practice, and the radiation field avoiding the truncated regionshould be set if necessary to reduce the influence of the truncated region on dosimetry.

7.
Chinese Journal of Trauma ; (12): 136-141, 2022.
Article in Chinese | WPRIM | ID: wpr-932218

ABSTRACT

Objective:To investigate the clinical effect of combined treatment of comminuted inferior pole patellar fracture with micro-plate and tension-band wire.Methods:A retrospective cohort study was conducted in 50 patients with comminuted inferior pole patellar fracture (AO classification of type 34-A1) admitted to First Affiliated Hospital of University of Science and Technology of China from October 2018 to October 2020, including 28 males and 22 females, aged 17-77 years[(51.4±11.5)years]. A total of 23 patients were treated with micro-plate combined with tension-band wire (Group A) and 27 patients were treated with cable wire looping combined with tension-band wire (Group B). Fracture union, union time and last follow-up evaluation of knee range of motion and Bostman score were compared between the two groups. Complications (infection, internal fixation failure, internal fixation irritation, etc.) were also observed.Results:All patients were followed up for 12-18 months[(14.1±2.1) months]. All patients had bone union, with no statistical difference between Group A[(9.9±1.8)weeks]and Group B[(10.3±1.4)weeks]in union time ( P>0.05). Knee range of motion was (129.2±9.7)° in Group A at the last follow-up, better than (122.3±11.0)° in Group B ( P<0.05). Knee Bostman score was (27.6±1.8)points in Group A, showing no statistical difference from that in Group B[(26.8±1.9)points]( P>0.05). There were no postoperative complications in Group A. Two patients with tension band shedding of Kirschner wire after fracture healing were found in Group B, with no special treatment given due to no obvious discomfort. Conclusions:For comminuted inferior pole patellar fracture, micro-plate combined with tension-band wire is more effective and provides better knee mobility with no complications of implant failure as compared with cable wire looping combined with tension-band wire. Therefore, the technique deserves clinical promotion.

8.
Chinese Journal of Radiological Health ; (6): 366-370, 2021.
Article in Chinese | WPRIM | ID: wpr-974383

ABSTRACT

Medical images can provide clinicans with accurate and comprehensive patients’ information. Morphological or functional abnormalities caused by various diseases can be manifested in many aspects. Although MR images and CT images can highlight the medical image data of different tissue structures of patients, single MR images or CT images cannot fully reflect the complexity of diseases. Using MR image to predict CT image is one of the cross-modal prediction of medical images. In this paper, the methods of MR image prediction for CTmage are classified into four categoriesincluding registration based on atlas, based on image segmentationmethod, based on learning method and based on deep learning method. In our research, we concluded that the method based on deep learning should bemore promoted in the future by compering the existing problems and future development of MR image predicting CT image method.

9.
Chinese Journal of Radiation Oncology ; (6): 1292-1296, 2021.
Article in Chinese | WPRIM | ID: wpr-910553

ABSTRACT

Objective:To explore the volume resolution of prostate motion target by four-dimensional (4D) ultrasound.Methods:The prostate ultrasound model was selected, and the group comparison study was conducted using 4D ultrasound to outline the prostate target under different motion amplitudes (A) and motion period (T). The simulated A value was set as 0.5 mm, 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm, respectively. The T value was set as 1 s, 2 s, 3 s, and 4 s, respectively. The volume of the target of the model prostate was calculated, and the static ultrasound image of the target was used as the control group to analyze the difference between two groups.Results:When the model was still, the size of the target of ultrasound was consistent with that of CT scan ( P>0.05). When the A values were 0.5 mm and 1 mm, there was no statistical difference between the volume in period 1-4 s and the volume in the target at rest (all P>0.05). When the A values were 2 mm and 3 mm, and the T values were 1 s, 2 s and 3 s there was statistical difference between the volume of target and that of of static ultrasonic target (all P<0.05). When the A value was 2 mm and the T value was 4 s, there was no statistical difference between the target volume and the static target volume ( P=0.710). The range within the group was 6.7 cm 3, and the standard deviation was 1.15 cm 3. When the A value was 3 mm and the T value was 4 s, the volume repeatability of the target was poor, and the range within the group was 14.4 cm 3; when the A values were 4 mm and 5 mm, and the T values were 1-4 s, the range within the group was 3.27-17.63 cm 3 and 6.51-21.02 cm 3, respectively. The volume repeatability of the target under each period was extremely poor, which could not meet the clinical requirements. Conclusion:4D ultrasound can provide reliable reference data for patients′ target delineation within 1-4 s of motion cycle and within 1 mm of motion amplitude, which exerts on effect upon the original position of probe.

10.
Chinese Journal of Radiological Medicine and Protection ; (12): 492-498, 2021.
Article in Chinese | WPRIM | ID: wpr-910345

ABSTRACT

Objective:To develop a 3D visualization technology-assisted patient positioning system for radiotherapy and compare it with traditional patient positioning method for breast and pelvic radiotherapy.Methods:A total of 40 patients receiving radiotherapy in Changzhou No.2 People′s Hospital from June 2020 to April 2021 were selected for this study, including 20 patients with breast cancer and 20 patients with pelvic cancer.3D visualization reconstruction was carried out using the CT data of the patients for positioning. Then the 3D visualization models were integrated with the real treatment environment and were then shifted to the isocentral positions of accelerators through interactive operations. Based on this, the patients were actually positioned. Every week, all of the patients were firstly treated with traditional positioning, followed by 3D visualization-guided positioning. As a result, 240 times of positioning data of all patients were collected in three weeks. They were compared with the data of cone-beam CT(CBCT)-guided positioning, which served as the gold standard.Results:The absolute positioning errors of 3D visualization-guided positioning along x, y and z axes were (1.92±1.23), (2.04±1.16), and (1.77±1.37)mm, respectively for patients with breast cancer and were (2.07±1.08), (1.33±0.88), and (1.99±1.25)mm, respectively for patients with pelvic cancer. Compared with traditional positioning method , the accuracy of 3D visualization-guided positioning along x、 y, and z axes was increased by 38.83%, 52.40% and 33%, respectively for patients with breast cancer and was improved by 36.84%, 54.04% and 52.58% for patients with pelvic cancer, with all differences being statistically significant along y and z axes ( t=2.956-5.734, P< 0.05). Meanwhile, the error distribution of the two positioning method was statistically significant along in y axis for patients with breast cancer( χ2=7.481, P<0.05) and was statistically significant along each axis for patients with pelvic cancer( χ2=5.900, 6.415, 7.200, P<0.05). Conclusions:The positioning method guided by 3D visualization technology can effectively improve the positioning accuracy of patients with breast cancer and patients with pelvic cancer and is of value in potential clinical application.

11.
Asian Journal of Andrology ; (6): 484-489, 2021.
Article in English | WPRIM | ID: wpr-888460

ABSTRACT

Surgical correction can be considered for treating patients with a chronic phase of Peyronie's disease (PD) and persistent penile curvature. In clinical practice, some patients pay too much attention to surgical complications and refuse the recommended feasible surgical types. Meanwhile, they require operations according to their preferences. This study aimed to evaluate the effects of patients' own choice of surgical type on postoperative satisfaction. This retrospective study analyzed data from 108 patients with PD who underwent surgical correction according to doctors' recommendations or patients' own demands. The objective and subjective surgical outcomes were assessed. Patients' understanding of the disease was analyzed using a questionnaire survey. Objective measurements of surgical outcomes, including penile straightening, penile length, and sexual function, in patients who received the recommended surgery, were similar to those in patients who did not accept the recommended surgery. However, subjective evaluations, including erectile pain, discomfort because of nodules on the penis, and decreased sensitivity in the penis, were more obvious in patients who did not follow doctors' recommendations. In addition, a questionnaire survey showed that understanding PD and the purpose of surgery of patients who did not follow doctors' advice were inappropriate, as they did not conform to the principle of treatment. The present study showed that surgical correction seemed to be an objectively effective option in the management of patients in the stable chronic phase of PD. Low patient satisfaction might be related to patients' lack of correct understanding of the disease and its treatment strategy as well as unrealistic expectations.

12.
Journal of Forensic Medicine ; (6): 519-524, 2020.
Article in English | WPRIM | ID: wpr-985147

ABSTRACT

Objective To establish a method for determination of escitalopram in biological samples by ultrasound-assisted ionic liquid-dispersive liquid-liquid microextraction combined with gas chromatography-tandem mass spectrometry (GC-MS/MS) and provide evidences for forensic determination of cases related to escitalopram. Methods The 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) was selected as an extract solvent to process biological samples. Ultrasound-assisted extraction was used on the samples. Then the samples were detected by GC-MS/MS. Results The linear range of escitalopram in blood and liver were 5.56-1 111.10 ng/mL and 0.025-5.00 mg/g, respectively. The correlation coefficient (r) were greater than 0.999, limit of detection (LOD) were 4.00 ng/mL and 2.00 μg/g, limit of quantitation (LOQ) were 14.00 ng/mL and 6.00 μg/g, respectively. The extraction recovery rates were all greater than 50%, the interday and intraday precision were less than 20%. Escitalopram was detected in blood and liver samples from the actual poisoning case by this method with a content of 1.26 μg/mL and 0.44 mg/g, respectively. Conclusion The ultrasound-assisted ionic liquid-dispersive liquid-liquid microextraction combined with GC-MS/MS is environment friendly, rapid, has good enriching effect and consumes less organic solvent and can be used for forensic determination of escitalopram related cases.


Subject(s)
Citalopram , Gas Chromatography-Mass Spectrometry , Limit of Detection , Liquid Phase Microextraction , Tandem Mass Spectrometry
13.
Chinese Journal of Radiological Medicine and Protection ; (12): 813-819, 2020.
Article in Chinese | WPRIM | ID: wpr-868531

ABSTRACT

Objective:To observe the effect and underlying mechanism of down-regulation of VEGFA on the radiosensitivity of esophageal cancer ECA-109 cells.Methods:Esophageal cancer cells were divided into four groups: sh-VEGFA group, vector control group, X-ray plussh-VEGFA group and X-ray plus vector group. The expressions of VEGFA gene and protein were detected by qPCR and Western blot, respectively. Cell proliferation and survival was measured by CCK8 assay and cloning formation, respectively. Cell apoptosis was detected by flow cytometry, and γ-H2AX foci were detected by immune-fluorescence assay.Results:Compared with the vector group, the expression of VEGFA gene was decreased in sh-VEGFA group ( t=11.98, P<0.05), and the expression of VEGFA protein was also reduced( t=12.38, P<0.05). After VEGFA being down-regulated, the cell proliferation( A450)was obviously inhibited( t=2.78, 7.25, 21.93, 13.21, P<0.05), and the cell clone formation of the sh-VEGFA group was significantly decreased so that D0, Dqand SF2 of sh-VEGFA group were decreased( t=5.83, 8.56, 7.68, P<0.05), and SERD0and SERDqwere increased. Compared with the vector group, the apoptosis rate in the sh-VEGFA group and the X-ray group was significantly increased and further increased in the sh-VEGFA plus X-ray group( t=17.63, 22.48, 33.87, P<0.05), and the number of γ-H2AX foci in both sh-VEGFA and vector groups were significantly increased within 2 h after X-ray irradiation. At 24 h after irradiation, the number of γ-H2AX foci returned to normal level in the vector group but remained at a higher level in the sh-VEGFA group ( t=7.00, P<0.05). Conclusions:Down-regulation of VEGFA inhibits the proliferation and colony formation, promotes apoptosis and hence increases the radiosensitivity of esophageal carcinoma cells via a pathway related to DNA damage repair.

14.
China Pharmacy ; (12): 1272-1276, 2020.
Article in Chinese | WPRIM | ID: wpr-821619

ABSTRACT

OBJECTIVE:To investiga te the role of clinical pharmacists in drug therapy for patients with severe pemphigus. METHODS:Clinical pharmacists participated in drug therapy for a patient with severe pemphigus. Clinical pharmacist adjusted the doctor’s medication plan in time according to the symptoms and adverse reactions of the patients. In view of several new blisters on the hand palms and back that may be caused by hormone reduction ,the clinical pharmacist suggested that the dosage of Prednisone acetate tablets should be adjusted to 70 mg before administration ,once a day. For poor infection control ,it was recommended to adjust the dose of minocycline to 100 mg,bid;for hypokalemia ,the clinical pharmacist advised the patients to take potassium orally,and added it into juice ,milk or honey for taking ;in order to prevent osteoporosis caused by glucocorticoid ,the clinical pharmacist suggested that patients supplement Calcium carbonate and vitamin D 3 chewable tablets and Alendronate sodium and vitamin D 3 tablets 70 mg at the same time ,once a week. For Candida albicans in patient ’s oral mucosa ,according to the results of drug sensitivity test ,the clinical pharmacists suggested that Itraconazole capsules should be adjusted to Fluconazole capsules 50 mg,once a day. At the same time ,pharmacist paid close attention to the adverse reactions after the infusion of Rituximab injection and pharmaceutical care was provided ,such as ADR monitoring ,discharge medication education. RESULTS :The doctors took all the advice of clinical pharmacists. The patient recovered and was discharged 47 days later. CONCLUSIONS :During drug therapy for the patient with severe pemphigus. Clinical pharmacists can help doctors improve the treatment plan so as to ensure the effectiveness and safety of patients ’medication.

15.
Journal of Medical Biomechanics ; (6): E364-E371, 2020.
Article in Chinese | WPRIM | ID: wpr-862393

ABSTRACT

Objective To study the relationship of the tibial plateau subchondral trabecular bone (STB) microstructure and the cartilage degeneration with the lower limb alignment based on individual trabecula segmentation (ITS) and histology analysis in knee osteoarthritis (OA). Methods Hip-knee-ankle (HKA) angles were measured on the full-length lower extremity films of patients before total knee arthroplasty (TKA). The tibial plateau excised from the TKA were collected for micro-CT scanning and ITS analysis. The cartilage degeneration was evaluated by histology. The relationship between the HKA angle and the changes in microstructural parameters of STB and cartilage degeneration were analyzed. ResultsThe plate, rod and axial bone trabecular volume fraction (BV/TV, pBV/TV, pBV/TV), ratio of trabecular plate versus rod (P/R), plate trabecular number density (pTb.N), plate trabecular thickness (pTb.Th), trabecular plate surface area (pTb.S), trabecular rod length (rTb.L), and plate-plate and plate-rod junction density (P-P Junc.D, P-R Junc.D) of the subchondral bone of the tibial plateau were significantly related to the cartilage degeneration OARSI score and the HKA angle. The greater the deviation of the lower limb alignment, the greater the number of subchondral trabeculae, the thicker the trabeculae, the greater the bone mass, the stronger the connectivity, especially the plate trabeculae on the affected side of tibial plateau, and the higher the OARSI score of cartilage degeneration. Conclusions Abnormal lower limb alignment may cause abnormal microstructure of the plate and rod STB of the tibial plateau by changing the stress distribution of the knee, especially the significant increase and thickening of the plate trabecular and axial trabecular bone, which may be an important risk factor that further aggravates the degeneration of articular cartilage and the progress of OA. Therefore, lower limb alignment correction with surgical intervention and improving STB with bone metabolism agents may efficiently contribute to preventing cartilage damage and mitigate OA progression.

16.
Chinese Journal of Gastrointestinal Surgery ; (12): 1041-1050, 2019.
Article in Chinese | WPRIM | ID: wpr-801343

ABSTRACT

Objective@#To investigate the diagnosis and treatment for enterocutaneous fistula (ECF) in China, and to explore the prognostic factors of ECF.@*Methods@#A multi-center cross-sectional study was conducted based on the Registration System of Chinese Gastrointestinal Fistula and Intra-Abdominal Infections to collect the clinical data of ECF patients from 54 medical centers in 22 provinces/municipalities from January 1, 2018 to December 31, 2018. The clinical data included patient gender, age, length of hospital stay, intensive care unit (ICU) admission, underlying diseases, primary diseases, direct causes of ECF, location and type of ECF, complications, treatment and outcomes. All medical records were carefully filled in by the attending physicians, and then re-examined by more than two specialists. The diagnosis of ECF was based on the clinical manifestations, laboratory/imaging findings and intraoperative exploration.@*Results@#A total of 1521 patients with ECF were enrolled, including 1099 males and 422 females, with a median age of 55 years. The top three primary diseases of ECF were malignant tumors in 626 cases (41.2%, including 540 gastrointestinal tumors, accounting for 86.3% of malignant tumors), gastrointestinal ulcers and perforations in 202 cases (13.3%), and trauma in 157 cases (10.3%). The direct causes of ECF were mainly surgical operation in 1194 cases (78.5%), followed by trauma in 156 (10.3%), spontaneous fistula due to Crohn′s disease in 92 (6.0%), radiation intestinal injury in 41 (2.7%), severe pancreatitis in 20 (1.3%), endoscopic treatment in 13 (0.9%) and 5 cases (0.3%) of unknown reasons. All the patients were divided into three groups: 1350 cases (88.7%) with simple ECF, 150 (9.9%) with multiple ECF, and 21 (1.4%) with combined internal fistula. Among the patients with simple ECF, 438 cases (28.8%) were jejuno-ileal fistula, 313 (20.6%) colon fistula, 170 (11.2%) rectal fistula, 111 (7.3%) duodenal fistula, 76 (5.0%) ileocecal fistula, 65 (4.3%) ileocolic anastomotic fistula, 55 (3.6%) duodenal stump fistula, 36 (2.4%) gastrointestinal anastomotic fistula, 36 (2.4%) esophagogastric/esophagojejunal anastomotic fistula, 29 (1.9%) gastric fistula and 21 (1.4%) cholangiopancreatiointestinal. Among all the simple ECF patients, 991 were tubular fistula and 359 were labial fistula. A total of 1146 patients finished the treatment, of whom 1061 (92.6%) were healed (586 by surgery and 475 self-healing) and 85 (7.4%) died. A total of 1043 patients (91.0%) received nutritional support therapy, and 77 (6.7%) received fistuloclysis. Infectious source control procedures were applied to 1042 patients, including 711 (62.0%) with active lavage and drainage and 331 (28.9%) with passive drainage. Among them, 841 patients (73.4%) underwent minimally invasive procedures of infectious source control (replacement of drainage tube through sinus tract, puncture drainage, etc.), 201 (17.5%) underwent laparotomy drainage, while 104 (9.1%) did not undergo any drainage measures. A total of 610 patients (53.2%) received definitive operation, 24 patients died within postoperative 30-day with mortality of 3.9% (24/610), 69 (11.3%) developed surgical site infection (SSI), and 24 (3.9%) had a relapse of fistula. The highest cure rate was achieved in ileocecal fistula (100%), followed by rectal fistula (96.2%, 128/133) and duodenal stump fistula (95.7%,44/46). The highest mortality was found in combined internal fistula (3/12) and no death in ileocecal fistula. Univariate prognostic analysis showed that primary diseases as Crohn′s disease (χ2=6.570, P=0.010) and appendicitis/appendiceal abscess (P=0.012), intestinal fistula combining with internal fistula (χ2=5.460, P=0.019), multiple ECF (χ2=7.135, P=0.008), esophagogastric / esophagojejunal anastomotic fistula (χ2=9.501, P=0.002), ECF at ileocecal junction (P=0.012), non-drainage/passive drainage before the diagnosis of intestinal fistula (χ2=9.688, P=0.008), non-drainage/passive drainage after the diagnosis of intestinal fistula (χ2=9.711, P=0.008), complicating with multiple organ dysfunction syndrome (MODS) (χ2=179.699, P<0.001), sepsis (χ2=211.851, P<0.001), hemorrhage (χ2=85.300, P<0.001), pulmonary infection (χ2=60.096, P<0.001), catheter-associated infection (χ2=10.617, P=0.001) and malnutrition (χ2=21.199, P<0.001) were associated with mortality. Multivariate prognostic analysis cofirmed that sepsis (OR=7.103, 95%CI:3.694-13.657, P<0.001), complicating with MODS (OR=5.018, 95%CI:2.170-11.604, P<0.001), and hemorrhage (OR=4.703, 95%CI: 2.300-9.618, P<0.001) were independent risk factors of the death for ECF patients. Meanwhile, active lavage and drainage after the definite ECF diagnosis was the protective factor (OR=0.223, 95%CI: 0.067-0.745, P=0.015).@*Conclusions@#The overall mortality of ECF is still high. Surgical operation is the most common cause of ECF. Complications e.g. sepsis, MODS, hemorrhage, and catheter-associated infection, are the main causes of death. Active lavage and drainage is important to improve the prognosis of ECF.

17.
Chinese Journal of Radiation Oncology ; (6): 297-301, 2019.
Article in Chinese | WPRIM | ID: wpr-745299

ABSTRACT

Objective An improved method for obtaining pseudo-computed tomography (CT ps) based on ultrasound deformation field.Methods The three-dimensional image data of computed tomography and ultrasound for three postoperative cervical cancer patients were selected,including the CT (CTsim) and ultrasound (USsim) images obtained during the simulated positioning stage,and the cone beam CT (CBCT) and ultrasound images obtained during the positioning verification stage of the treatment one week later.Binary masks of the OROI and OROW were created and applied in ultrasound image registration;thus,the deformation field was obtained.The deformation field was applied to CTsim images and different pseudo-CT images were obtained.Similarities between these pseudo-CT images and those of CBCT were compared,and registration accuracies between pseudo-CT images under different binary masks and CTsim were discussed.Results The averages of the correlation coefficient between pseudo-CT based on OROI,OROW,no binary mask and CBCT were 0.95,0.82 and 0.64 respectively.The average of the normalized mean square Error were 0.12,0.42 and 0.57 respectively.Conclusion The pseudo-CT based on OROI binary mask matches the best with CTsim and achieves the highest similarity with CBCT.

18.
Chinese Journal of Radiation Oncology ; (6): 680-684, 2018.
Article in Chinese | WPRIM | ID: wpr-708260

ABSTRACT

Objective To compare the dose difference between the 12-bit and 16-bit CT images containing metallic implants calculated by different algorithms. Methods The titanium alloy rod was inserted into the phantom and subject to CT scan and then the 12-bit and 16-bit CT images were reconstructed. The CT images were online transmitted to the Monaco planning system and a 0° of single field was designed. The dose distribution was calculated by PB (Pencil Beam), CC (Collapsed Cone) and MC (Monte Carlo) algorithms, respectively. The CT-ED curve was expanded and the dose was recalculated. The depth dose curve through the center of the metallic implants along with the direction of the field was obtained by using the Matlab 8. 3 statistical software. The dose distribution curves between 12-bit and 16-bit CT images calculated by different algorithms and the dose difference of varying distances between the incident and the exit surfaces of metallic implants were statistically compared. The dose was measured by thimble chamber. Results The 16-bit CT images accurately read the CT values of the metallic implants. After the CT-ED curve was expanded, the dose on the incident surface of metallic implant was reduced by 5. 43% and that on the exit surface was increased by 25. 56% calculated by PB algorithm compared with MC algorithm. The dose on the posterior exit surface was higher than that of MC algorithm. The dose on the incident surface of metallic surface was decreased by 4. 5%, whereas that on the exit surface was reduced by 4. 31% using CC algorithm. The dose on the posterior exit surface was more significantly reduced. The calculated values by MC algorithm were the most close to the measured values. Conclusions Application of 16-bit CT image, CT-ED curve expansion of the treatment planning system combined with MC algorithm can enhance the accuracy of dose calculation for the patients containing metallic implants during radiotherapy.

19.
Chinese Journal of Radiological Medicine and Protection ; (12): 306-310, 2017.
Article in Chinese | WPRIM | ID: wpr-512178

ABSTRACT

Objective To investigate the impact on registration accuracy with the different registration ranges of CBCT images and CT images.Methods CBCT and CT scans were performed on the of 5 patients.The registration ranges of five patients' images of abdomen,head and chest performed CBCT and CT scanning were processed with four modes.Mode 1:the registration range of CT images was larger than the registration range of CBCT images,mode 2:the registration range of CT images and CBCT images were equally,mode 3:taking a 5 cm translation of CT images range from mode 2,mode 4:The CBCT range and CT range reduced 2 cm both sides simultaneously from mode 2.Using the registration program from Insight Segmentation and Registration Toolkit (ITK) to the four modes,the Mean Square Difference (MSD) metric values of four modes after registration were compared and the relationship between mode 2 and another three modes was analyzed by paired t test.Results For the MSD metric values,mode 3 was maximum,mode 2 and 4 were minimum,and mode 1 was centered.The difference between the mode 2 and mode 4 was not statistically significant(P > 0.05).The difference between the mode 2 and mode 1 was statistically significant(t =-4.586,-4.164,-5.618,P < 0.05).The difference between the mode 2 and mode 3 was statistically significant(t =-6.423,-8.109,-19.601,P<0.05).Conclusion The registration ranges of CBCT and CT images has a certain extent of influence on the accuracy of image registration.The closer the registration range of CBCT and CT is,the higher the registration accuracy is.

20.
Chinese Journal of Radiological Medicine and Protection ; (12): 938-945, 2017.
Article in Chinese | WPRIM | ID: wpr-666019

ABSTRACT

Objective To apply metal artifact reduction algorithm to reduce metal artifacts based on 12 bit and 16 bit CT images,and aimed to analyze the effects on CT value and dose distribution.Methods The metal implant was inserted into the phantom,and the original 12 bit CT image and original 16 bit CT image were derived from CT scanning.The images were processed using NMAR algorithm,so the corrected 12 bit image and corrected 16 bit image were obtained.A patient's CT was chosen with artificial femur,and used the NMAR algorithm to reduce metal artifacts.Furthermore,the CT values of original images and corrected images were compared and analyzed.In the planning system,dose distribution was calculated based on each image by same radiation treatment plan.The dose distribution difference of each image was compared and analyzed.Results For the 12 bit image,the CT value of metal was 3 071 HU,which was much smaller than the metal's actual CT value ll 080 HU.The metal's CT value for the 16bit image was 11 098 HU,which was very close to the actual value.The original CT images contained a lot of artifacts around the metal,resulting in a large deviation of CT values from the reference image.After NMAR correction,metal artifacts were reduced significantly,and the CT values were close to the reference images.The dose distribution of the corrected 16 bit image was closest to that of the reference image.The maximum dose deviation on the central axis was 1.8%.The difference between the 12 bit image and the reference image downstream the metal was notable,and the maximum dose deviation on the central axis was 81.6%.The X-rays passed through the artifact region in original image,the dose distribution was obviously different from the reference image,and the maximum dose deviation was 21.6%.Conclusions For the patient with metal implant,using the NAMR algorithm on the 16 bit image result in accurate CT value of CT image,so that the accurate dose distribution will be obtained.

SELECTION OF CITATIONS
SEARCH DETAIL