Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Aesthetics and Cosmetology ; (6): 404-406, 2012.
Article in Chinese | WPRIM | ID: wpr-430530

ABSTRACT

Objective To evaluate the efficacy and safety of 650 nm,810 nm diode laser on the treatment of moderate to severe acne.Methods A total of 87 patients with moderate to severe acne were divided into diode laser group (group A) and medication group (group B).In group A,the patients were irradiated with 650,810 nm diode laser at the fluence of 400-450 mW distance of 2-3 cm.In group B,the patients were treated with roxithromycin combined with vitamin B6 and gel lincomycini.Clinical follow-up was performed every week for 4 months.All the adverse effects were recorded.Results There was no significantly statistical difference in the cure rate between the two groups (group A versus group B at 2 weeks:65.0 % versus 42.6 %,P>0.05; at 4 weeks:92.5 % versus 76.5 %,P>0.05).However,the recurrence rate of group A was much lower than that of group B (30.0 % versus 61.7 %,P<0.01).There were no severe adverse effects in both groups during the period of the follow-up.Conclusions Compared to the medication,650,810 nm diode laser appears to be associated with lower recurrence rate in the treatment of moderate to severe acne.

2.
Chinese Journal of Dermatology ; (12): 336-338, 2011.
Article in Chinese | WPRIM | ID: wpr-412642

ABSTRACT

Objective To estimate the application value of a standard operating procedure (SOP) in the detection of syphilitic anticardiolipin reagin. Methods Clinical laboratories from 9 local hospitals in Shanghai participated the program. Quality control samples with unknown target value were qualitatively and quantitatively examined according to the uniform SOP in these laboratories with the same reagent and facility of horizontal reaction. External quality assessment (EQA) was carried out by using seven serum samples with no, or low (1∶ 128 dilution) to high (1∶1 dilution) concentrations of target before and after the implementation of SOP. The test results were statistically analyzed and the reasons for the detecting error were assessed. Results A total of 388 tests were performed in the 9 clinical laboratories. The total accuracy rate was 93.0%, including 40.2% in the detection of samples with 1 ∶ 8 dilution of target, 49.2% in the detection of samples with 1 ∶ 16 dilution of target, and 3.6% in the detection of samples with 1 ∶ 32 dilution of target. No forward bias was observed in these tests. There was a significant difference in the accuracy rate between the two times of EQA before and after the implementation of SOP (x2 = 4.17, P < 0.05). Conclusions The improved standard procedure for nontreponemal antigen test is beneficial to the decrease of testing error, and may provide a basis for the establishment of SOP and implementation of internal quality assessment.

SELECTION OF CITATIONS
SEARCH DETAIL