Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. bras. anestesiol ; 69(3): 253-258, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1013415

ABSTRACT

Abstract Background and objectives: The current study aimed to determine the minimum effective volume (MEV) of bupivacaine 0.5% in 50% of patients for an ultrasound-guided retroclavicular approach to infraclavicular brachial plexus block. Methods: A total of 25 adult patients who were scheduled for upper limb surgery received an ultrasound-guided retroclavicular approach to infraclavicular brachial plexus block with bupivacaine 0.5%. The needle insertion point was posterior to the clavicle and the needle was advanced from cephalad to caudal. Block success was defined as a composite score of 14 at 30 min after local anesthetic (LA) injection. The minimum effective volume in 50% of patients was determined using the Dixon-Massey up-and-down staircase method. Minimum effective volume for a successful block in 95% of the patients was also calculated using logistic regression and probit transformation. Results: The minimum effective volume of bupivacaine 0.5% resulting in successful block in 50% of patients (MEV50) according to the up-and-down staircase method was found to be 9.6 mL (95% confidence interval (CI), 5.7-13.4). The calculated minimum effective volume required for a successful block in 95% of patients (MEV95) using the probit transformation and logistic regression analysis was 23.2 mL (95% CI, 18.8-36.7). Conclusions: The MEV50 of bupivacaine 0.5% for US-guided retroclavicular approach to infraclavicular brachial plexus block was 9.6 mL and the calculated MEV95 was 23.2 mL. Future studies are required for infraclavicular brachial plexus block with different approaches, other LA agents and different concentrations of bupivacaine.


Resumo Justificativa e objetivos: Determinar o volume mínimo efetivo (VE) de bupivacaína a 0,5% em 50% dos pacientes para uma abordagem retroclavicular guiada por ultrassom no bloqueio do plexo braquial por via infraclavicular. Métodos: Um total de 25 pacientes adultos agendados para cirurgia do membro superior receberam abordagem retroclavicular guiada por ultrassom para o bloqueio do plexo braquial por via infraclavicular com bupivacaína a 0,5%. O ponto de inserção da agulha foi posterior à clavícula e a agulha foi avançada de cefálica para caudal. O sucesso do bloqueio foi definido como um escore composto de 14 aos 30 min após a injeção do anestésico local. O VE em 50% dos pacientes foi determinado com o método de escalonamento progressivo-regressivo de Dixon-Massey. O VE para um bloqueio bem-sucedido em 95% dos pacientes também foi calculado com regressão logística e transformação probit. Resultados: O volume mínimo efetivo (VE50) de bupivacaína a 0,5% que resultou em bloqueio bem-sucedido em 50% dos pacientes, de acordo com o método de escalonamento progressivo-regressivo, foi de 9,6 ml (intervalo de confiança de 95%, IC 5,7-13,4). O cálculo do volume mínimo efetivo necessário para um bloqueio bem-sucedido em 95% dos pacientes (VE95) com a análise de transformação probit e regressão logística foi de 23,2 ml (IC 95%, 18,8-36,7). Conclusões: O VE50 de bupivacaína a 0,5% para abordagem retroclavicular guiada por US para o bloqueio do plexo braquial por via infraclavicular foi de 9,6 ml e o VE95 calculado foi de 23,2 ml. Estudos futuros são necessários para o bloqueio do plexo braquial por via infraclavicular com diferentes abordagens, outros anestésicos locais e diferentes concentrações de bupivacaína.


Subject(s)
Humans , Male , Female , Adult , Bupivacaine/administration & dosage , Ultrasonography, Interventional/methods , Brachial Plexus Block/methods , Anesthetics, Local/administration & dosage , Upper Extremity/surgery , Dose-Response Relationship, Drug , Middle Aged
2.
Rev. bras. anestesiol ; 68(5): 524-527, Sept.-Oct. 2018. graf
Article in English | LILACS | ID: biblio-958327

ABSTRACT

Abstract Atrial myxoma is a benign tumor of the heart that occurs primarily in the left atrium. Floating or large left atrial myxomas frequently cause functional mitral stenosis, may also affect mitral valve structure and flow, and lead to mitral regurgitation. Systemic embolization occurs in around 30% of cases either from tumor fragmentation or complete tumor detachment hence it should be removed as soon as it is detected. Intraoperative transesophageal echocardiography has a vital importance in the surgery. After resection of myxoma, intraoperative transesophageal echocardiography must be performed to rule out residual mass. The case here reported is of a 48-year old female, who presented with giant and floating left atrial myxoma. Residue mass was detected with intraoperative transesophageal echocardiography in the left ventricle after the resection of myxoma. Subsequently, the residue mass was successfully removed. Complete resection must be required to prevent possible complications such as recurrence, embolization in atrial myxomas. Transesophageal echocardiography performed intraoperatively is vital importance to confirm that the myxoma is completely resected.


Resumo Mixoma atrial é um tumor benigno do coração que ocorre principalmente no átrio esquerdo. Os mixomas flutuantes ou grandes em átrio esquerdo com frequência causam estenose mitral funcional, podendo também afetar a estrutura e o fluxo da válvula mitral e levar à insuficiência mitral. A embolização sistêmica ocorre em cerca de 30% dos casos, quer pela fragmentação do tumor ou pelo desprendimento total do tumor; portanto, o tumor deve ser removido assim que detectado. A ecocardiografia transesofágica intraoperatória tem uma importância vital na cirurgia. Após a ressecção do mixoma, a ecocardiografia transesofágica intraoperatória deve ser feita para excluir a massa residual. O caso aqui relatado é o de uma paciente de 48 anos que apresentou um mixoma de átrio esquerdo gigante e flutuante. A massa residual foi detectada com ecocardiografia transesofágica intraoperatória no ventrículo esquerdo após a ressecção do mixoma. Posteriormente, a massa residual foi removida com sucesso. A ressecção completa é necessária para evitar possíveis complicações, como recorrência e embolização em mixomas atriais. A ecocardiografia transesofágica realizada no intraoperatório é de vital importância para confirmar a ressecção completa do mixoma.


Subject(s)
Humans , Female , Middle Aged , Echocardiography, Transesophageal/instrumentation , Heart Neoplasms/diagnostic imaging , Myxoma/diagnosis , Neoplasm, Residual
SELECTION OF CITATIONS
SEARCH DETAIL