Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 6-10, 2019.
Article in Chinese | WPRIM | ID: wpr-734307

ABSTRACT

Objective To explore the clinical application value of second-generation dual-source CT combined with intelligent modulation and iterative reconstruction in emergency aortic dissection imaging.Methods A total of 40 emergency patients with clinical suspected aortic dissection were included in this study.Conventional scanning was performed in the control group,and large-pitch intelligent modulation and iterative reconstruction were performed in the test group.The mean CT value,mean noise,signal noise ratio(SNR),contrast noise ratio(CNR),effective dose,image quality and aortic root image quality were evaluated and analyzed.Results Totally 40 patients successfully completed CT aortic dissection imaging.There was no difference in image quality between the two groups (P> 0.05).The quality of aortic root images in the test group was better than that in the control group,and the difference was statistically significant(x2=22.556,P<0.05).The mean CT value and mean noise of aorta in the control group were slightly higher than those in the test group.However,SNR and CNR in the test group were higher than those in the control group,and the difference was statistically significant (t =-21.042,-15.924,8.530,11.495,P<0.05).The effective dose of the control group [(10.59±3.89)mSv] was significantly higher than that [(6.39±0.81) mSv] of the test group,the difference was statistically significant (t =-12.327,P<0.05).Conclusions The combined intelligent modulation technique and iterative reconstruction technique with dual-source CT large pitch scanning can meet the requirements of image quality and reduce the effective dose,and can be used as a conventional imaging method for emergency CT of aortic dissection.

2.
Journal of Practical Radiology ; (12): 666-669, 2018.
Article in Chinese | WPRIM | ID: wpr-696880

ABSTRACT

Objective To assess the value of cardiac magnetic resonance (CMR) imaging in left ventricular structure and function in patients with end stage renal disease (ESRD).Methods Twenty-five patients with ESRD and 10 healthy subjects underwent CMR.Left ventricular end diastolic volume(EDV),end-diastolic diameter(EDD),end-systolic volume(ESV),end-systolic diameter(ESD),stroke volume(SV),ejection fraction(EF),LVM and interventricular septum (IVS) thickness were measured and compared.The parameters from CMR and 2DTTE were compared.Results The EF in patients with ESRD was significantly lower than that in controls (P<0.001),while ESV,ESD,IVS and LVM were respectively higher than these in controls (P<0.05).There was no significant difference (P>0.05) in ESV between CMR and 2DTTE,but EF of CMR was significantly higher than this of 2DTTE (P<0.05).There was no significant difference (P =0.296) in left ventricular systolic functional category.Bland-Altman plots showed a good agreement between the two methods.Conclusion CMR is a helpful tool to assess left ventricular structure and function in patients with ESRD.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 389-392, 2017.
Article in Chinese | WPRIM | ID: wpr-610067

ABSTRACT

Objective To investigate the feasibility and clinical value of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV in chest CT scan.Methods A total of 60 patients of clinical diagnosis with lung tumor were enrolled.Those patients were randomly divided into test group and control group.Control group underwent a scan protocol with lateral scout scan combined with Care Dose 4D and Care kV,while anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV were performed in test group.The signal-to-noise ration (SNR),contrast-to-noise ratio (CNR),and overall image quality of two groups of images and diseased tissues were analyzed and evaluated by two high-grade radiologists using double-blind method.Effective doses (E) were also calculated.Results All the 60 patients had successfully completed the chest CT scans.Test group overall image quality (4.57 ± 0.45) and control group overall image quality (4.73 ± 0.45) had no statistically significant difference (P > 0.05).The control group image SNR,CNR and diseased tissue SNR,CNR compared with test group had no statistical significance difference (P > 0.05).The difference of the volume CT dose index (CTDIvol),dose-length product (DLP) and effective dose (E) of test group and control group was statistically significant (t =8.514,8.464,8.464,P < 0.001).Compared with control group,the effective dose of test group decreased by 33.3%.Conclusions Compared with lateral scout scan,the technology of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV can decrease radiation dose without reducing the image quality.This technology can therefore be considered as a regular imaging modality for chest CT scan.

4.
Journal of Practical Obstetrics and Gynecology ; (12): 36-39, 2010.
Article in Chinese | WPRIM | ID: wpr-403678

ABSTRACT

Objective:To investigate the clinical efficacy of fluorescence in situ hybridization(FISH)in prenatal diagnosis of chromosomal aneuploidy.Methods:FISH and karyotyping analysis were done in 120 samples of amniotic fluid from pregnant women.Results:FISH analysis results were consistent with those of karyotyping,the dectecting rate can reach 100%for chromosomal aneuploidies.There was no significant difference in the preference for FISH or karyotying for prenatal diagnosis when facing high matemal age,multi-indications and other factors(P>0.05).FISH was better when biochemical datafor down's syndrome were positive (P=0.029),however karyotyping was better when there was abnormal fetal ultrasound scan(P=0.000).Conclusions:FISH can detect the chromosomal aneuploidy quickly and accurately,especially when biochemical data for down's syndrome were positive.FISH could be the first choice for prenatal diagnosis in the third trimester of high-risk pregnancy.

SELECTION OF CITATIONS
SEARCH DETAIL