Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Gut and Liver ; : 476-485, 2021.
Article in English | WPRIM | ID: wpr-898453

ABSTRACT

Background/Aims@#Although endoscopic transpapillary gallbladder drainage (ETGBD) has been reported as an alternative procedure for acute cholecystitis, it requires advanced endoscopic techniques. In terms of the certainty of achieving drainage, it remains a challenging procedure. The aim of the current study was to elucidate the practical efficacy of cholangioscopic assistance and to develop a new classification that could be used to evaluate the technical difficulty of ETGBD and provide a theoretical strategy to apply cholangioscopy appropriately for difficult ETGBD. @*Methods@#A total of 101 patients undergoing ETGBD were retrospectively studied. The characteristics and technical outcomes of ETGBD with conventional ETGBD (C-ETGBD) and SpyGlass DS-assisted ETGBD (SG-ETGBD) were evaluated. The characteristics and technique-dependent factors of unsuccessful C-ETGBD/SG-ETGBD were evaluated using the classification based on the steps of the procedure. The predictive factors of successful C-ETGBD/SG-ETGBD were examined. @*Results@#C-ETGBD was successful in 73 patients (72.3%). SG-ETGBD was successful in 11 of 13 patients (84.6%) who had C-ETGBD failure. Optional SG-ETGBD significantly increased the final success rate (94.1%) compared to C-ETGBD alone (p=0.003). ETGBD procedures could be classified into four steps. SG-assistance worked as an excellent troubleshooter in step 1 (failure to identify the cystic duct orifice) and step 2 (failure of guidewire advancement across the downturned angle of cystic duct takeoff). Magnetic resonance cholangiopancreatography could provide predictive information based on the classification. @*Conclusions@#Optional SG-ETGBD achieved a significantly higher success rate than C-ETGBD alone. Step classification is helpful for determining the technical difficulty of ETGBD and developing a theoretical strategy to apply cholangioscopy in a coordinated manner.

2.
Gut and Liver ; : 476-485, 2021.
Article in English | WPRIM | ID: wpr-890749

ABSTRACT

Background/Aims@#Although endoscopic transpapillary gallbladder drainage (ETGBD) has been reported as an alternative procedure for acute cholecystitis, it requires advanced endoscopic techniques. In terms of the certainty of achieving drainage, it remains a challenging procedure. The aim of the current study was to elucidate the practical efficacy of cholangioscopic assistance and to develop a new classification that could be used to evaluate the technical difficulty of ETGBD and provide a theoretical strategy to apply cholangioscopy appropriately for difficult ETGBD. @*Methods@#A total of 101 patients undergoing ETGBD were retrospectively studied. The characteristics and technical outcomes of ETGBD with conventional ETGBD (C-ETGBD) and SpyGlass DS-assisted ETGBD (SG-ETGBD) were evaluated. The characteristics and technique-dependent factors of unsuccessful C-ETGBD/SG-ETGBD were evaluated using the classification based on the steps of the procedure. The predictive factors of successful C-ETGBD/SG-ETGBD were examined. @*Results@#C-ETGBD was successful in 73 patients (72.3%). SG-ETGBD was successful in 11 of 13 patients (84.6%) who had C-ETGBD failure. Optional SG-ETGBD significantly increased the final success rate (94.1%) compared to C-ETGBD alone (p=0.003). ETGBD procedures could be classified into four steps. SG-assistance worked as an excellent troubleshooter in step 1 (failure to identify the cystic duct orifice) and step 2 (failure of guidewire advancement across the downturned angle of cystic duct takeoff). Magnetic resonance cholangiopancreatography could provide predictive information based on the classification. @*Conclusions@#Optional SG-ETGBD achieved a significantly higher success rate than C-ETGBD alone. Step classification is helpful for determining the technical difficulty of ETGBD and developing a theoretical strategy to apply cholangioscopy in a coordinated manner.

3.
Gut and Liver ; : 47-54, 2017.
Article in English | WPRIM | ID: wpr-100545

ABSTRACT

BACKGROUND/AIMS: Self-expandable metallic stent (SEMS) placement is effective for dysphagia that results from malignant obstruction of the esophagus or gastric cardia; however, stent-related complications may be life-threatening. Thus, the goal of this study was to identify risk factors associated with complications following esophageal stenting. METHODS: Of the 71 patients who underwent SEMS placement for dysphagia as a result of malignant stricture of the esophagus or gastric cardia, 53 patients with squamous cell carcinoma or adenocarcinoma, without previous SEMS placement, without a fistula, and without recurrent tumor after surgery were retrospectively identified. The occurrence of stent-related complications was used as an endpoint. RESULTS: Stent-related complications were identified in 26 patients (49.1%), and major complications occurred in 14 patients (26.4%). The use of an Ultraflex stent (odds ratio [OR], 6.81; 95% confidence interval [CI], 1.54 to 30.00; p=0.011) and prior chemotherapy (OR, 6.13; 95% CI, 1.46 to 25.70; p=0.013) were significantly associated with stent-related complications. Moreover, the use of an Ultraflex stent (OR, 19.60; 95% CI, 2.26 to 170.00; p=0.007) and prior radiation (OR, 25.70; 95% CI, 2.37 to 280.00; p=0.008) significantly increased the risk of major complications. CONCLUSIONS: The use of an Ultraflex stent and prior radiation and/or chemotherapy may represent risk factors for complications following esophageal SEMS placement.


Subject(s)
Humans , Adenocarcinoma , Carcinoma, Squamous Cell , Cardia , Constriction, Pathologic , Deglutition Disorders , Drug Therapy , Esophagus , Fistula , Retrospective Studies , Risk Factors , Stents
4.
Gut and Liver ; : 51-57, 2016.
Article in English | WPRIM | ID: wpr-111618

ABSTRACT

BACKGROUND/AIMS: A barbed puncture needle with a side hole was recently developed to improve sample quality and quantity in endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). In this study, we retrospectively assessed the usefulness of this puncture needle. METHODS: Factors affecting diagnostic yield, safety, and diagnostic accuracy were investigated in 76 patients who consecutively underwent EUS-FNA for neoplastic lesions at our hospital between January and December 2013. RESULTS: The procedure was successful in all cases; the rates of sample collection and determination of the correct diagnosis were 92.1% and 89.5%, respectively. The mean number of needle passes required for diagnosis was 1.1. Complications included mild intraluminal bleeding in two patients (2.6%). Multivariate analysis revealed that lesion size (< or =20 mm) was significantly associated with a decreased chance of determining the correct diagnosis. CONCLUSIONS: Core biopsy needles with a side hole are safe and provide a satisfactory diagnostic yield. However, the side hole may potentially reduce the rate of making the correct diagnosis in small lesions.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Digestive System Neoplasms/diagnosis , Endoscopic Ultrasound-Guided Fine Needle Aspiration/instrumentation , Equipment Design , Equipment Safety , Gastrointestinal Tract/pathology , Multivariate Analysis , Needles/adverse effects , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL