Indian Heart J ; 2022 Aug; 74(4): 322-326
Article | IMSEAR | ID: sea-220917

ABSTRACT

Background: The distal radial artery (dRA) approach at anatomical snuff box has gained attention of the interventional cardiologist in last few years. The procedural success rate by this novel approach depends on size of the radial artery and therefore the study was planned to study the size of distal radial artery. Methods: Total of 1004 patients of >18 years of age undergoing coronary catheterization were included in the study. The vessel diameter was measured from media to media in the anatomical snuff box a day prior to coronary catheterization. Results: The mean diameter of right radial artery at conventional access site was 2.56 ± 0.35 mm and at distal access site 2.23 ± 0.39 mm (p < 0.001). Females had significantly smaller radial artery diameter as compared to males at right conventional access site (2.42 ± 0.36 mm vs 2.60 ± 0.34 mm; p < 0.001) and distal access site (2.09 ± 0.38 mm vs 2.27 ± 0.39 mm; p < 0.001). The diameter of the right dRA was not significantly correlated with age (r2 linear ¼ 0.002, p ¼ 0.0475) but was positively correlated with height and weight (r2 linear ¼ 0.076, p ¼ <0.001 and r2 linear ¼ 0.005, p ¼ <0.001) and negatively correlated with BMI (r2 linear ¼ 0.076, p ¼ 0.519). Conclusions: This study has shown the size of right dRA 2.27 þ 0.39 mm in males and 2.09 þ 0.38 mm in females. Diabetes, hypertension, height and weight are important predictors of dRA diameter