Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Journal of the Korean Ophthalmological Society ; : 899-903, 2023.
Article in Korean | WPRIM | ID: wpr-1001814

ABSTRACT

Purpose@#To compare the effectiveness of warm saline and anti-fog solution for preventing fogging of a non-contact wide-field viewing system during vitrectomy. @*Methods@#Five liters of water at 36°C were placed in a transparent container. The fogging areas of wide-field lenses were microscopically measured. We created three groups: lenses soaked in normal saline at 25°C for 1 minute (control), lenses soaked in normal saline at 50°C for 1 minute (warm saline), and lenses that were wiped with a sponge soaked in anti-fog solution (ULTRASTOP pro med. Solution, Sigmapharm, Vienna, Austria) after prior soaking in normal saline at 25°C for 1 minute (anti-fog). Images of fogged areas were acquired at 10 seconds and 1, 3, and 5 minutes. Extent of fogged areas and central lens invasion were determined. All experiments were repeated 10 times. @*Results@#In the control group, the entire areas were always completely fogged. The average fog coverage values were 4.34 ± 1.28, 6.30 ± 1.38, 56.00 ± 25.01, and 93.81 ± 5.88% at 10 seconds and 1, 3, and 5 minutes in the warm saline group and 4.74 ± 0.57, 7.35 ± 0.96, 10.13 ± 1.09, and 11.74 ± 1.74% in the anti-fog group, respectively. There were significant differences at 3 and 5 minutes (p = 0.029, p = 0.012). Fogging of the central lens was detected in 8 tests after 3 minutes and all 10 tests after 5 minutes in the warm saline group, but no fogging was detected in the anti-fog group. @*Conclusions@#Application of an anti-fog solution to a wide-field viewing lens prevents lens fogging during vitrectomy.

2.
Journal of the Korean Ophthalmological Society ; : 1014-1021, 2023.
Article in Korean | WPRIM | ID: wpr-1001798

ABSTRACT

Purpose@#To compare the safety and consistency of manual capsulorhexis and precision pulse capsulotomy performed using pulsed energy during bilateral cataract surgery and to explore the differences in clinical outcomes. @*Methods@#A total of 101 patients with bilateral cataracts were selected. Precision pulse capsulotomy was performed on one eye and manual continuous curvilinear capsulorhexis on the other. The independent-samples t-test was used to compare the duration of continuous curvilinear capsulorhexis, incisional size and roundness, complications such as radial tears, the cumulative dissipated energy, the visual acuity after surgery, and the corneal epithelial cell count. @*Results@#There was no significant difference in the capsulorhexis time between the pulse energy and manual groups. The extent of capsulorhexis was significantly smaller and the circularity of capsulorhexis was higher in the former group. Complications occurred in two manual capsulorhexis patients but in no pulse energy capsulotomy patient. There was no significant between- group difference in any of postoperative visual acuity, best-corrected visual acuity, or the corneal endothelial cell count. @*Conclusions@#During bilateral cataract surgery on the same patients, precision capsulotomy using pulse energy afforded smaller and more circular capsulorhexis and fewer complications than did manual capsulorhexis. However, there was no significant between- group difference in the postoperative clinical outcomes.

3.
Journal of the Korean Ophthalmological Society ; : 482-490, 2020.
Article | WPRIM | ID: wpr-833293

ABSTRACT

Purpose@#To compare the vessel density (VD) and foveal avascular zone (FAZ) area using four different optical coherence tomography angiography (OCTA) images. @*Methods@#This prospective study analyzed the OCTA images of consecutive healthy subjects using Plex-Elite (Carl Zeiss), DRI OCT-1 Atlantis (Topcon), AngioPlex (Carl Zeiss), and Spectralis OCTA (Heidelberg Engineering). The VD and FAZ areas were calculated using the OCTA images with a 3 x 3 mm2 volume scan pattern centered on the fovea. @*Results@#The VD (%) of the superficial capillary plexus (SCP) and deep capillary plexus (DCP) were different using the four devices: Plex-Elite (42.17 ± 2.79, 43.71 ± 2.36), DRI OCT-1 Atlantis (28.70 ± 2.87, 30.27 ± 3.02), AngioPlex (28.32 ± 6.68, 33.33 ± 5.44), and Spectralis OCTA (27.86 ± 4.13, 28.54 ± 3.14), respectively; p 0.05), but the FAZ area had positive correlations using the four devices (all, p < 0.001). @*Conclusions@#The four OCTA devices provided different VD and FAZ areas, so these differences should be considered in analyzing OCTA images.

4.
Journal of the Korean Ophthalmological Society ; : 1613-1617, 2014.
Article in Korean | WPRIM | ID: wpr-41569

ABSTRACT

PURPOSE: To assess the changes in mean corneal refractive power (DeltaK) following pterygium surgery and to predict DeltaK in cases of combined cataract and pterygium surgery. METHODS: Thirty-seven eyes of unilateral pterygium patients who underwent pterygium surgery were analyzed retrospectively with at least more than 1 month of follow-up. Preoperative and postoperative 1 month corneal refractive power was measured using auto-keratometer (RK-F1, Canon, Tokyo, Japan). Pterygium horizontal extension, width, and area were measured and correlation with DeltaK before and after surgery analyzed. We also compared DeltaK of the contralateral normal eye. RESULTS: The mean corneal refractive (Km) power measured before and 1 month after surgery was 43.30 +/- 1.66 D and 44.07 +/- 1.42 D, respectively. The Km significantly increased at 4 weeks after surgery (p < 0.001). However, postoperative Km was not significantly different when compared with the contralateral normal eye (43.86 +/- 1.34 D; p = 0.59). All parameters of pterygium size including horizontal extension, width, and area were positively correlated with the mean DeltaK. Among parameters, horizontal extension was best correlated with mean DeltaK (p < 0.001). The mean DeltaK with horizontal extension was predicted using linear regression (2.5 mm to 1 D, 4.0 mm to 1.8 D). CONCLUSIONS: We recommend contralateral corneal refractive power or prediction of corneal refractive power using linear regression with pterygium horizontal extension for determining intraocular lens power in cases of combined cataract and pterygium surgery.


Subject(s)
Humans , Cataract , Follow-Up Studies , Lenses, Intraocular , Linear Models , Pterygium , Retrospective Studies
5.
Journal of the Korean Ophthalmological Society ; : 1525-1529, 2014.
Article in Korean | WPRIM | ID: wpr-51810

ABSTRACT

PURPOSE: To investigate the effects of watching three-dimensional (3D) television (TV) on the angle of deviation and refractive error in children with exodeviation. METHODS: Twenty-three volunteers with exodeviation, aged 6 to 12 years, without any ocular abnormalities other than refractive error and exodeviation were recruited for this study. The subjects watched 3D TV for 50 minutes at a viewing distance of 2.8 meters. The image disparity of 3D contents was -1 to 1 degree. Refractive errors were measured before and immediately after watching TV and after a 10-minute rest. The changes in angle of deviation were also obtained. Refractive errors and angle of deviation before and after watching 3D TV were compared. RESULTS: The mean age of the subjects was 9.30 +/- 1.58 years. The mean baseline angle of deviation was 13.04 +/- 5.25 (6-30) prism diopters (PD), which did not change significantly immediately after watching 3D TV and after a 10-minute rest (p = 0.452). The mean refractive errors were -2.15 +/- 1.55 D in the right eye and -2.06 +/- 1.55 D in the left eye before and changed to -2.14 +/- 1.57 D and -2.11 +/- 1.45 D, respectively, immediately after watching 3D TV. After a 10 minute rest, the mean refractive errors were 2.14 +/- 1.53 D in the right eye and -2.07 +/- 1.53 D in the left eye. All changes in refractive errors were not statistically significant (p = 0.991 in right eye, 0.495 in left eye). The amount of myopic shift in both eyes immediately after watching 3D TV was correlated with the angle of exodeviation (r = 0.468, p = 0.024). However, the correlation disappeared after a 10-minute rest (r = 0.345, p = 0.107). CONCLUSIONS: Watching properly made 3D contents on 3D TV for 50 minutes at more than 2.8 meters of viewing distance did not affect the refractive error in children with exodeviation. Further studies on the relationship between the amount of myopic shift and the angle of exodeviation are necessary.


Subject(s)
Child , Humans , Exotropia , Imaging, Three-Dimensional , Refractive Errors , Television , Volunteers
SELECTION OF CITATIONS
SEARCH DETAIL