Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2013 July; 61(7): 361-364
Article in English | IMSEAR | ID: sea-148216

ABSTRACT

This study was done to compare the results of posterior continuous curvilinear capsulorhexis created using forceps with those created using vitrector in eyes suffering from congenital cataract. Vitrectorhexis term was first used by Wilson et al in 1999.[1] Fifty eyes with congenital and developmental cataract were included in this study. The posterior capsulorhexis was created using utrata forceps in 17 eyes or through a vitrector in 33 eyes. Forceps capsulorhexis was performed before IOL implantation, while vitrectorhexis was performed after IOL implantation in the bag. The results of both the surgery were compared using the following criteria: incidence of extension of rhexis, ability to achieve posterior rhexis of appropriate size, ability to implant the IOL in the bag, the surgical time, and learning curve. Vitrectorhexis after IOL implantation was an easy to learn alternative to manual posterior continuous curvilinear capsulorhexis in pediatric cataract surgery. It was more predictable and reproducible, with a short learning curve and lesser surgical time.

2.
Indian J Ophthalmol ; 2012 May; 60(3): 218-220
Article in English | IMSEAR | ID: sea-139475

ABSTRACT

Foldable intraocular lens (IOL) implantation using an injector system through 2.8-mm clear corneal incision following phacoemulsification provides excellent speedy postoperative recovery. In our reported case, a Sensar AR40e IOL (Abbott Medical Optics, USA) was loaded into Emerald C cartridge, outside the view of the operating microscope, by the first assistant. The surgeon proceeded with the IOL injection through a 2.8-mm clear corneal incision after uneventful phacoemulsification, immediately following which he noted a Descemet's tear with a rolled out flap of about 2 mm near the incision site. Gross downward beaking of the bevelled anterior end of the cartridge was subsequently noticed upon examination under the microscope. We suggest careful preoperative microscopic inspection of all instruments and devices entering the patient's eyes to ensure maximum safety to the patient.


Subject(s)
Cartilage , Descemet Membrane/injuries , Equipment Failure , Eye Injuries/etiology , Humans , Injections/adverse effects , Injections/instrumentation , Intraoperative Complications , Lens Implantation, Intraocular/adverse effects , Lens Implantation, Intraocular/instrumentation , Rupture
SELECTION OF CITATIONS
SEARCH DETAIL