Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Arq. bras. oftalmol ; 82(6): 522-527, Nov.-Dec. 2019. graf
Article in English | LILACS | ID: biblio-1038687

ABSTRACT

ABSTRACT A 26-year-old woman presented at 28 weeks gestation with hypertensive choroidopathy associated with pre-eclampsia. Fundus photography, fundus autofluorescence, spectral-domain optical coherence tomography (SD-OCT), fluorescein angiography, and indocyanine green angiography were performed in both eyes in the immediate postoperative period. SD-OCT images were obtained before delivery and during a 3-month follow-up. Fundus autofluorescence exhibited patchy hyper- and hypoautofluorescent lesions; fluorescein and indocyanine green angiography revealed areas of choroidal ischemia; and SD-OCT showed disorganization of the outer retinal layers and disruption of the ellipsoid zone. After her blood pressure was stabilized, progressive recovery of the outer retinal layer was monitored on SD-OCT.


RESUMO Uma mulher de 26 anos de idade, com 28 semanas de gestação apresentando coroidopatia hipertensiva associada à pré-eclâmpsia. Retinografia, autofluorescência, tomografia de coerência óptica de domínio espectral, angiofluoresceínografia e angiografia com indocianina verde foram realizadas em ambos os olhos no período pós-operatório imediato do parto. Imagens da tomografia de coerência óptica de domínio espectral foram obtidas antes do parto e durante o seguimento de 3 meses. A autofluorescência apresentou lesões heterogêneas hiper e hipoautofluorescentes, a angiofluoresceínografia e angiografia com indocianina verde revelaram áreas de isquemia de coroide, e a tomografia de coerência óptica de domínio espectral apresentou desorganização das camadas externas da retina e interrupção da zona elipsóide. Após a estabilização da pressão sanguínea, a recuperação progressiva da camada externa da retina foi monitorada pela tomografia de coerência óptica de domínio espectral.


Subject(s)
Humans , Female , Pregnancy , Adult , Pre-Eclampsia , Choroid Diseases/etiology , Choroid Diseases/diagnostic imaging , Hypertension/etiology , Hypertension/diagnostic imaging , Remission, Spontaneous , Fluorescein Angiography/methods , Tomography, Optical Coherence/methods , Retinal Pigment Epithelium/pathology , Retinal Pigment Epithelium/diagnostic imaging
2.
Arq. bras. oftalmol ; 77(6): 403-410, Nov-Dec/2014. graf
Article in English | LILACS | ID: lil-735806

ABSTRACT

Pattern electroretinography is used to assess the function of the inner retinal layers, particularly the retinal ganglion cell layer, using a reversing checkerboard or grating pattern that maintains a constant overall mean luminance over time. A normal transient response comprises a positive component of the wave (P50) followed by a longer negative component of the wave (N95). Glaucomatous optic neuropathy causes progressive loss of retinal ganglion cells, potentially detectable as abnormalities on examination, particularly in the N95 component. Therefore, pattern electroretinography may be useful in the diagnosis and evaluation of glaucoma. The present article is an updated review of published data regarding the use of pattern electroretinography for the detection of glaucoma-induced retinal changes.


O eletroretinograma de padrão reverso é utilizado para avaliar a função das camadas internas da retina, particularmente a camada de células ganglionares retinianas, utilizando um estímulo em xadrez ou barras alternantes, mantendo constante o nível de contraste total. A resposta transiente normal é constituída por uma onda positiva (P50) seguida de uma onda maior negativa (N95). A neuropatia óptica glaucomatosa causa perda progressiva das células ganglionares da retina, detectável como anormalidades no exame, especialmente na onda N95. Por isso, o eletroretinograma de padrão reverso pode ser útil no diagnóstico e seguimento de pacientes glaucomatosos. Este artigo é uma revisão atualizada dos dados publicados a respeito da capacidade do eletroretinograma de padrão reverso em detectar alterações retinianas induzidas pelo glaucoma.


Subject(s)
Humans , Electroretinography/methods , Glaucoma/diagnosis , Glaucoma/physiopathology , Optic Nerve Diseases/diagnosis , Optic Nerve Diseases/physiopathology , Optic Nerve/physiopathology , Visual Fields/physiology
3.
Arq. bras. oftalmol ; 75(1): 53-58, jan.-fev. 2012. tab
Article in English | LILACS | ID: lil-622547

ABSTRACT

PURPOSE: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. METHODS: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. RESULTS: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] µm and 84.3 [20.2] µm, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] µm and 117.0 [17.7] µm, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). CONCLUSIONS: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.


OBJETIVO: Avaliar as medidas da camada de fibras nervosas da retina com a tomografia de coerência óptica (OCT) "time domain" (TD) e "spectral domain" (SD), e testar a habilidade diagnóstica de ambas as tecnologias em pacientes com perda assimétrica glaucomatosa de hemicampo visual. MÉTODOS: Trinta e seis pacientes com glaucoma primário de ângulo aberto com perda de campo visual em um hemicampo (acometido) e ausência de perda no hemicampo oposto (não-acometido), e 36 controles pareados por idade tiveram o olho de estudo examinado com Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) e 3 D OCT-1000 (Topcon, Tokyo, Japan). As medidas de espessura da camada de fibras nervosas da retina peripapilar e classificação normativa fornecida pelos aparelhos foram registrados para análise. A média aritmética dos valores do gráfico de desvio total em cada hemicampo foi calculada para cada indivíduo. "Índices de assimetria" para campo visual e camada de fibras nervosas da retina foram calculados como a razão entre hemicampos acometido e não-acometido e hemirretinas correspondentes, respectivamente. RESULTADOS: As medidas da camada de fibras nervosas da retina em hemicampos não-acometidos (média [SD] 87.0 [17.1] µm e 84.3 [20.2] µm, para TD e SD-OCT, respectivamente) foram menores do que em controles (119.0 [12.2] µm e 117.0 [17.7] µm, P<0.001). O banco de dados normativo classificou como alterado 42% e 67% das hemirretinas correspondentes a hemicampos não-acometidos com TD e SD-OCT, respectivamente (P=0.01). As medidas da camada de fibras nervosas da retina foram consistentemente mais espessas com TD comparados com SD-OCT. Índices de assimetria da camada de fibras nervosas da retina foram semelhantes entre TD (0.76 [0.17]) e SD-OCT (0.79 [0.12]) e significantemente maiores do que o índice de assimetria do campo visual (0.36 [0.20], P<0.001). CONCLUSÃO: Os hemicampos normais de pacientes com glaucoma apresentaram camada de fibras nervosas da retina mais fina do que olhos saudáveis. As medidas da camada de fibras nervosas da retina foram mais espessas com TD do que com SD-OCT, que por sua vez detectou anormalidades na espessura da camada de fibras nervosas da retina mais frequentemente do que o TD-OCT.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Glaucoma, Open-Angle/diagnosis , Nerve Fibers/pathology , Visual Fields/physiology , Case-Control Studies , Glaucoma, Open-Angle/physiopathology , Tomography, Optical Coherence , Visual Field Tests
SELECTION OF CITATIONS
SEARCH DETAIL