Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Fisioter. Pesqui. (Online) ; 24(1): 9-14, jan.-mar. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-892090

ABSTRACT

RESUMO A manovacuometria é um teste simples, rápido e não invasivo por meio do qual a pressão inspiratória máxima (PImáx) e a pressão expiratória máxima (PEmáx) são obtidas, a fim de auxiliar na avaliação muscular respiratória. Atualmente, há grande variedade de modelos e marcas de manovacuômetros, com diferentes diâmetros e comprimentos de traqueias, no entanto, a interferência desses modelos nas medidas obtidas por esses equipamentos necessita de investigação. Desta forma, o objetivo primário deste estudo foi verificar a influência do comprimento de traqueias nas pressões respiratórias máximas, obtidas por meio de manovacuômetro analógico, em indivíduos saudáveis e, secundariamente, se há correlação entre as medidas. Foram avaliados 50 indivíduos, de 18 a 30 anos, de ambos os sexos, por meio da espirometria e manovacuometria. As PImáx e PEmáx foram realizadas com uso de traqueias de mesmo diâmetro interno (0,5 cm) e comprimentos de 30, 60 e 90 cm. Foram observados valores significativamente menores de PImáx obtidos com a traqueia de comprimento de 90 cm comparados às PImáx obtidas com as traqueias de 30 e 60 cm (teste de Friedman's ANOVA com teste de Wilcoxon com ajuste de Bonferroni). As traqueias de 30, 60 e 90 cm de comprimento e mesmo diâmetro não influenciaram os valores de PEmáx e PImáx, exceto a traqueia de 90 cm para os valores de PImáx, o que pode interferir na prática clínica fisioterapêutica. Novos estudos são necessários para analisar a necessidade de padronização do comprimento da traqueia utilizada em manovacuômetros.


RESUMEN La manovacuometría es una prueba sencilla, rápida y no invasiva por la cual se obtienen la presión inspiratoria máxima (PImax) y la presión espiratoria máxima (PEmax), con el objetivo de ayudar en el examen muscular respiratorio. Hoy día se encuentran una gran variedad de modelos y marcas de manovacuometros, con diferentes diámetros y longitudes de las tráqueas, pero hacen falta estudios sobre la interferencia de estos modelos en las mediciones por este instrumento. En este texto se propone examinar en sujetos sanos, en primer lugar, la influencia en la longitud de las tráqueas en las presiones respiratorias máximas, obtenidas por manovacuometros analógicos, y en segundo lugar comprobar la existencia de correlación entre las mediciones. Se evaluaron a cincuenta sujetos entre 18 y 30 años de edad, tanto varones como mujeres, empleando la espirometría y la manovacuometría. Se midió la PImax y la PEmax empleando tráqueas de mismo diámetro interno (0,5 cm) y con longitudes de 30, 60 e 90 cm. Se observaron valores significativamente menores de PImax con la tráquea de longitud de 90 cm en comparación con las PImax con las tráqueas de 30 y 60 cm (prueba de Friedman's ANOVA, la de Wilcoxon con ajustes de Bonferroni). Las tráqueas de 30, 60 y 90 cm de longitud y mismo diámetro no influyeron en los valores de la PEmax y de la PImax, con excepción de la tráquea de 90 cm en los valores de la PImax, lo que puede interferir la práctica clínica fisioterapéutica. Se necesitan más estudios para evaluar la necesidad de estándares de la longitud de tráqueas empleadas en manovacuometros.


ABSTRACT Manovacuometry is a simple, fast, and non-invasive test, with maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) obtained to assist respiratory muscle assessment. Currently, there is a wide variety of models and brands of manovacuometers with different trachea diameters and lengths. However, the interference of these models in the measurements obtained by these equipments needs to be investigated. Thus, this study mainly aimed to verify the influence of tracheal length on maximal respiratory pressures (MRP), obtained by an analog manovacuometer, in healthy individuals. Our secondary objective was to verify the correlation between measurements. Fifty individuals, aged 18 to 30, of both sexes, were evaluated by spirometry and manovacuometry. MIP and MEP were performed using tracheas with same internal diameter (0.5 cm) and 30 cm, 60 cm, and 90 cm length. Significantly lower MIP values were observed when comparing a 90 cm trachea to 30 and 60 cm tracheas (Friedman's ANOVA test and Wilcoxon test with Bonferroni adjustment). Tracheas with 30, 60, and 90 cm length and same diameter did not affect MIP and MEP values, except the 90 cm trachea for MIP values, which may interfere in the physical therapy clinical practice. Further studies are required to analyze the need for standardizing the trachea length used in manovacuometers.

2.
Rev. bras. med. esporte ; 20(3): 214-218, May-Jun/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-718418

ABSTRACT

INTRODUÇÃO: Os testes caminhada de seis minutos (TC6) e degrau de seis minutos (TD6) são meios de avaliação da capacidade funcional. No entanto, pouco se sabe sobre sua reprodutibilidade em adultos jovens. OBJETIVO: Avaliar a reprodutibilidade relativa e absoluta tanto intra quanto inter-avaliadores do TC6 e TD6 em indivíduos adultos jovens. MÉTODOS: Foram avaliados 33 indivíduos adultos jovens aparentemente saudáveis por meio da espirometria; e realizados os testes TC6 e TD6. Três (T1, T2 e T3) TC6 e TD6 foram feitos em cada indivíduo, sendo o último de cada teste realizado por um avaliador diferente. Para a análise intra-avaliadores foram comparados os desempenhos do T1 e T2 enquanto que a análise inter-avaliadores foi feita pela comparação dos desempenhos do T3 com: T1; T2; e escolha do melhor dos primeiros dois testes. Foi calculado o coeficiente de correlação intra-classe (CCI) como medida da reprodutibilidade relativa; o erro padrão de medida; a diferença mínima detectável; traçados gráficos de Bland-Altman e teste ANOVA para analisar a reprodutibilidade absoluta. RESULTADOS: Observaram-se, nos dois testes funcionais, intra e inter-avaliadores, valores excelentes de reprodutibilidade relativa (CCI>0,75) e a reprodutibilidade absoluta mostrou alto erro. CONCLUSÃO: O TD6 e o TC6 apresentaram reprodutibilidade intra e inter-avaliadores excelente para a população adulto jovem, mas altos valores de erro. .


INTRODUCTION: Six Minute Walk Test (6MWT) and Six Minute Step Test (6MST) are tests to evaluate functional capacity. However, reproducibility of these tests is still not well known in young adults. OBJECTIVE: To evaluate intra and inter-rater relative and absolute reproducibility of 6MWT and 6MST in young adults. METHODS: Thirty-three apparently health young adults were evaluated through spirometry, 6MWT and 6MST. Three (T1, T2 and T3) of each 6MWT and 6MST were carried out on each individual, the latter (T3) by a different evaluator. Intra-rater analysis was performed comparing the performance of T1 and T2, while the inter-rater analysis was executed using the comparisons of T3 with T1, T2 and the best result of the first two. Intra-class correlation coefficient (ICC) was calculated as a measure of relative reproducibility; the standard error of measurement, minimal detectable change, Bland-Altman plots and repeated measures ANOVA were used to verify absolute reproducibility. RESULTS: Excellent values of relative reproducibility (ICC>0.75) were observed in both 6MWT and 6MST, yet high error values were found in absolute reproducibility analysis. CONCLUSION: 6MWT and 6MST present excellent intra and inter-rater relative reproducibility, but high error values. .


INTRODUCCIÓN: Los tests de caminata de seis minutos (TC6) y escalón de seis minutos (TD6) son medios de evaluación de la capacidad funcional. Mientras tanto, poco se sabe sobre su reproductibilidad en adultos jóvenes. OBJETIVO: Evaluar la reproductibilidad relativa y absoluta tanto intra como inter-evaluadores del TC6 y TD6 en individuos adultos jóvenes. MÉTODOS: Fueron evaluados 33 individuos adultos jóvenes aparentemente saludables por medio de espirometría; y realizados los tests TC6 y TD6. Tres (T1, T2 y T3) TC6 y TD6 fueron hechos en cada individuo, siendo el último de cada test realizado por un evaluador diferente. Para el análisis intra-evaluadores fueron comparados los desempeños del T1 y T2 mientras que el análisis inter-evaluadores fue hecho por la comparación de los desempeños del T3 con: T1; T2; y selección del mejor de los primeros dos tests. Fue calculado el coeficiente de correlación intra-clase (CCI) como medida de la reproductibilidad relativa; el Error Estándar de Medida; la diferencia mínima detectable; trazados gráficos de Bland-Altman y test ANOVA para analizar la reproductibilidad absoluta. RESULTADOS: Se observaron, en los dos tests funcionales, intra e inter-evaluadores, valores excelentes de reproductibilidad relativa (CCI>0,75) y la reproductibilidad absoluta mostró alto error. CONCLUSIÓN: El TD6 y el TC6 presentaron reproductibilidad intra e inter-evaluadores excelente para la población adulto joven, pero altos valores de error. .

3.
J. bras. pneumol ; 39(2): 121-127, mar.-abr. 2013. tab
Article in Portuguese | LILACS | ID: lil-673302

ABSTRACT

OBJETIVO: Determinar se parâmetros obtidos antes e depois da realização do teste do degrau de seis minutos (TD6), respostas espirométricas após o TD6 e o nível de atividade física se correlacionam com a qualidade de vida de adolescentes asmáticos. MÉTODOS: Foram avaliados 19 adolescentes asmáticos, com idades variando de 11-15 anos, por meio de espirometria, TD6, International Physical Activity Questionnaire (IPAQ, Questionário Internacional de Atividade Física), Questionário sobre a Qualidade de Vida na Asma Pediátrica (QQVAP) e escala CR10 de Borg. RESULTADOS: Houve correlações negativas entre sensação de dispneia e pontuação total do QQVAP (r = -0,54) e de seus domínios limitação nas atividades (LA) e sintomas (r = -0,64 e r = -0,63, respectivamente), assim como entre fadiga nos membros inferiores (MMII) e os mesmos domínios (r = -0,49 e r = -0,56, respectivamente). O escore total do IPAQ correlacionou-se com a pontuação total do QQVAP (r = 0,47) e o domínio LA (r = 0,51), enquanto o tempo de caminhada correlacionou-se com o domínio sintomas (r = 0,45), e o tempo de atividade intensa correlacionou-se com o domínio LA (r = 0,50). Na análise de regressão, somente a sensação de dispneia associou-se significativamente ao escore total e o domínio limitação nas atividades do QQVAP, e o mesmo ocorreu entre a fadiga dos MMII e o domínio sintomas. CONCLUSÕES: Quanto maior for o nível de atividade física e menor for a dispneia e a fadiga nos MMII, melhor é a qualidade de vida. O TD6 mostrou-se uma opção na avaliação da capacidade ao exercício desses indivíduos por refletir o incômodo que a asma provoca na prática das atividades da vida diária.


OBJECTIVE: To determine whether the quality of life of adolescents with asthma correlates with parameters obtained prior to and after the six-minute step test (6MST); spirometric results after the 6MST; and level of physical activity. METHODS: Nineteen adolescents with asthma, ranging from 11-15 years of age, were assessed with spirometry, 6MST, the International Physical Activity Questionnaire (IPAQ), the Pediatric Asthma Quality of Life Questionnaire (PAQLQ), and the 10-point Borg category-ratio (CR10) scale. RESULTS: Sensation of dyspnea correlated negatively with the total PAQLQ score (r = -0.54) and with the scores of its activity limitation (AL) and symptoms domains (r = -0.64 and r = -0.63, respectively), leg fatigue also correlating negatively with those same domains (r = -0.49 and r = -0.56, respectively). The total IPAQ score correlated with total PAQLQ score (r = 0.47) and with the PAQLQ AL domain (r = 0.51); IPAQ time spent walking correlated with the PAQLQ symptoms domain (r = 0.45); and IPAQ time spent in vigorous activity correlated with the AL domain (r = 0.50). In the regression analysis, only sensation of dyspnea remained significantly correlated with the total PAQLQ score and its AL domain; leg fatigue remained significantly correlated with the symptoms domain. CONCLUSIONS: Higher levels of physical activity indicate better quality of life, as do lower perception of dyspnea and less leg fatigue. The 6MST proved to be a viable option for evaluating exercise capacity in adolescents with asthma, because it reflects the discomfort that asthma causes during activities of daily living.


Subject(s)
Adolescent , Child , Female , Humans , Male , Asthma/physiopathology , Dyspnea/physiopathology , Fatigue/physiopathology , Quality of Life , Exercise Test , Leg , Linear Models , Spirometry
SELECTION OF CITATIONS