Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
CoDAS ; 35(2): e20210201, 2023. tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1439934

ABSTRACT

RESUMO Objetivo O objetivo do presente estudo foi traduzir, adaptar e validar transculturalmente a versão para língua portuguesa brasileira do questionário Hearing Protection Assessment Questionnaire (HPA). Método O instrumento original, desenvolvido na língua inglesa, buscou avaliar as barreiras e suportes relacionados ao uso dos dispositivos de proteção auditiva (DPA), assim como o conhecimento, hábitos e atitudes dos trabalhadores frente ao ruído ocupacional. A tradução, adaptação e validação transcultural do questionário foi composta de cinco etapas: Tradução do questionário do inglês para o português; 2) Processo inverso de tradução do português para o inglês; 3) Análise do instrumento por três especialistas na área; 4) Pré-teste do questionário com 10 trabalhadores; 5) Aplicação do instrumento em 509 trabalhadores de uma indústria frigorífica após o exame admissional. Resultados os resultados indicam a validade de construção e conteúdo da versão em Português Brasileiro para o seu uso com uma população trabalhadora e a consistência interna do mesmo. Conclusão Este estudo resultou na tradução, na adaptação cultural e validação do questionário Hearing Protection Assessment Questionnaire (HPA) com a finalidade de ser usado para avaliar o uso de proteção auditiva individual em âmbito ocupacional, denominado Questionário de Avaliação da Proteção Auditiva (APA).


ABSTRACT Purpose The aim of the present study is to translate, adapt, and cross-culturally validate the Brazilian Portuguese version of the questionnaire Hearing Protection Assessment Questionnaire (HPA). Methods The original instrument, developed in English, seeks to assess barriers and supports related to the use of hearing protection devices (HPD), as well as workers' knowledge, habits and attitudes towards occupational noise. The translation, adaptation, and cross-cultural validation of the questionnaire consisted of five steps: Translation of the questionnaire from English to Portuguese; 2) Reverse translation from Portuguese to English; 3) Analysis of the instrument by three experts in the field; 4) Pre-test of the questionnaire with ten workers; 5) Application of the instrument to 509 workers in a meatpacking industry after the pre-employment medical exam. Results The results indicate the construction and content validity of the Brazilian Portuguese version for use with a working population and its internal consistency. Conclusion This study resulted in the translation, cultural adaptation, and validation of the Hearing Protection Assessment Questionnaire (HPA), in order to be used to assess the use of individual hearing protection in the occupational field, called Hearing Protection Assessment Questionnaire (HPA).

2.
Braz. j. otorhinolaryngol. (Impr.) ; 80(4): 296-304, Jul-Aug/2014. tab
Article in English | LILACS | ID: lil-721403

ABSTRACT

INTRODUCTION: Research has shown that hearing loss in musicians may cause difficulty in timbre recognition and tuning of instruments. AIM: To analyze the hearing thresholds from 250 Hz to 16,000 Hz in a group of music students and compare them to a non-musician group in order to determine whether high-frequency audiometry is a useful tool in the early detection of hearing impairment. METHODS: Study design was a retrospective observational cohort. Conventional and high-frequency audiometry was performed in 42 music students (Madsen Itera II audiometer and TDH39P headphones for conventional audiometry, and HDA 200 headphones for high-frequency audiometry). RESULTS: Of the 42 students, 38.1% were female students and 61.9% were male students, with a mean age of 26 years. At conventional audiometry, 92.85% had hearing thresholds within normal limits; but even within the normal limits, the worst results were observed in the left ear for all frequencies, except for 4000 Hz; compared to the non-musician group, the worst results occurred at 500 Hz in the left ear, and at 250 Hz, 6000 Hz, 9000 Hz, 10,000 Hz, and 11,200 Hz in both the ears. CONCLUSION: The periodic evaluation of high-frequency thresholds may be useful in the early detection of hearing loss in musicians. .


INTRODUÇÃO: Pesquisas comprovam que a perda auditiva em músicos pode gerar dificuldade no reconhecimento de timbres e na afinação dos instrumentos. OBJETIVO: Analisar os limiares auditivos de 250 Hz a 16.000 Hz de um grupo de estudantes de música e compará-los a um grupo de não músicos para determinar se a audiometria de altas frequências é um recurso útil na detecção precoce da deficiência auditiva. MÉTODO: Forma de estudo: observacional, de coorte, retrospectivo. Realizou-se audiometria convencional e de altas frequências em 42 estudantes de música (audiômetro Madsen Itera II, fones TDH39P para a audiometria convencional e HDA 200 para audiometria de altas frequências). RESULTADOS: Dos 42 estudantes, 38,10% eram do gênero feminino e 61,9% do gênero masculino, com média de 26 anos; na audiometria convencional 92,85% apresentaram limiares auditivos dentro dos padrões de normalidade; mesmo dentro da normalidade, piores resultados ocorreram na orelha esquerda para todas as frequências, excetuando-se 4000 Hz; quando comparado ao grupo de não músicos os piores resultados ocorreram em 500 Hz na orelha esquerda e 250 Hz, 6000 Hz, 9000 Hz, 10.000 Hz e 11.200 Hz em ambas as orelhas. CONCLUSÃO: A avaliação dos limiares de altas frequências de forma periódica pode ser útil na detecção precoce da deficiência auditiva em músicos. .


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Audiometry, Pure-Tone , Auditory Threshold/physiology , Hearing Loss/diagnosis , Music , Retrospective Studies , Students
SELECTION OF CITATIONS
SEARCH DETAIL